메뉴 건너뛰기




Volumn 50, Issue 5, 2008, Pages 423-427

Structural limitations of currently available microcatheters and coils for endovascular coiling of very small aneurysms

Author keywords

Aneurysm; Coil; Microcatheter

Indexed keywords

ANEURYSM; ARTICLE; COIL EMBOLIZATION; DETACHABLE COIL; EQUIPMENT DESIGN; EVALUATION; IMAGE ANALYSIS; INTRAVASCULAR CATHETER; MICROCATHETER; PRIORITY JOURNAL; SAFETY; STEREOMICROSCOPY;

EID: 42549137994     PISSN: 00283940     EISSN: None     Source Type: Journal    
DOI: 10.1007/s00234-008-0365-y     Document Type: Article
Times cited : (41)

References (10)
  • 1
    • 0030778130 scopus 로고    scopus 로고
    • Safety and efficacy of endovascular treatment of acutely ruptured aneurysms
    • Raymond J, Roy D (1997) Safety and efficacy of endovascular treatment of acutely ruptured aneurysms. Neurosurgery 41:1235-1246
    • (1997) Neurosurgery , vol.41 , pp. 1235-1246
    • Raymond, J.1    Roy, D.2
  • 3
    • 0034859836 scopus 로고    scopus 로고
    • Rupture of intracranial aneurysms during treatment with Guglielmi detachable coils: Incidence, outcome and risk factors
    • Sluzewski M, Bosch JA, van Rooij WJ, Nijssen PC, Wijnalda D (2001) Rupture of intracranial aneurysms during treatment with Guglielmi detachable coils: incidence, outcome and risk factors. J Neurosurg 94:238-240
    • (2001) J Neurosurg , vol.94 , pp. 238-240
    • Sluzewski, M.1    Bosch, J.A.2    Van Rooij, W.J.3    Nijssen, P.C.4    Wijnalda, D.5
  • 4
    • 33747452063 scopus 로고    scopus 로고
    • Procedural complications of coiling of ruptured intracranial aneurysms: Incidence and risk factors in a consecutive series of 681 patients
    • van Rooij W, Sluzewski M, Beute G, Nijssen P (2006) Procedural complications of coiling of ruptured intracranial aneurysms: incidence and risk factors in a consecutive series of 681 patients. AJNR Am J Neuroradiol 27:1498-1501
    • (2006) AJNR Am J Neuroradiol , vol.27 , pp. 1498-1501
    • Van Rooij, W.1    Sluzewski, M.2    Beute, G.3    Nijssen, P.4
  • 6
    • 33750710114 scopus 로고    scopus 로고
    • Endovascular surgery for very small ruptured intracranial aneurysms. Technical note
    • Suzuki S, Kurata A, Ohmomo T, Sagiuchi T, Niki J, Yamada M et al (2006) Endovascular surgery for very small ruptured intracranial aneurysms. Technical note. J Neurosurg 105:777-780
    • (2006) J Neurosurg , vol.105 , pp. 777-780
    • Suzuki, S.1    Kurata, A.2    Ohmomo, T.3    Sagiuchi, T.4    Niki, J.5    Yamada, M.6
  • 7
    • 0026355516 scopus 로고
    • Electrothrombosis of saccular aneurysms via endovascular approach. Part 2: Preliminary clinical experience
    • Guglielmi G, Viñuela F, Dion J, Duckwiler G (1991) Electrothrombosis of saccular aneurysms via endovascular approach. Part 2: Preliminary clinical experience. J Neurosurg 75:8-14
    • (1991) J Neurosurg , vol.75 , pp. 8-14
    • Guglielmi, G.1    Viñuela, F.2    Dion, J.3    Duckwiler, G.4
  • 8
    • 0036735720 scopus 로고    scopus 로고
    • Marker alignment for Guglielmi detachable coil embolization: Practical considerations
    • Kwon OK, Han MH (2002) Marker alignment for Guglielmi detachable coil embolization: practical considerations. AJNR Am J Neuroradiol 23:1276-1283
    • (2002) AJNR Am J Neuroradiol , vol.23 , pp. 1276-1283
    • Kwon, O.K.1    Han, M.H.2
  • 9
    • 2942635965 scopus 로고    scopus 로고
    • Distal-tip shape-consistency testing of steam-shaped microcatheters suitable for cerebral aneurysm coil placement
    • Abe T, Hirohata M, Tanaka N, Uchiyama Y, Fujimoto K, Fujimura N et al (2004) Distal-tip shape-consistency testing of steam-shaped microcatheters suitable for cerebral aneurysm coil placement. AJNR Am J Neuroradiol 25:1058-1061
    • (2004) AJNR Am J Neuroradiol , vol.25 , pp. 1058-1061
    • Abe, T.1    Hirohata, M.2    Tanaka, N.3    Uchiyama, Y.4    Fujimoto, K.5    Fujimura, N.6
  • 10
    • 33644836032 scopus 로고    scopus 로고
    • Shapability, memory, and luminal changes in microcatheters after steam shaping: A comparison of 11 different microcatheters
    • Kiyosue H, Hori Y, Matsumoto S, Okahara M, Tanoue S, Sagara Y et al (2005) Shapability, memory, and luminal changes in microcatheters after steam shaping: a comparison of 11 different microcatheters. AJNR Am J Neuroradiol 26:2610-2616
    • (2005) AJNR Am J Neuroradiol , vol.26 , pp. 2610-2616
    • Kiyosue, H.1    Hori, Y.2    Matsumoto, S.3    Okahara, M.4    Tanoue, S.5    Sagara, Y.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.