메뉴 건너뛰기




Volumn 26, Issue 10, 2005, Pages 2610-2616

Shapability, memory, and luminal changes in microcatheters after steam shaping: A comparison of 11 different microcatheters

Author keywords

[No Author keywords available]

Indexed keywords

ARTICLE; CATHETER; CATHETERIZATION; CLINICAL PROTOCOL; MEMORY; QUALITY CONTROL; CLASSIFICATION; COMPARATIVE STUDY; EQUIPMENT; EQUIPMENT DESIGN; HUMAN; INSTRUMENTATION; MEDICAL INSTRUMENTATION; STANDARD; WATER VAPOR;

EID: 33644836032     PISSN: 01956108     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (22)

References (4)
  • 1
    • 0033494196 scopus 로고    scopus 로고
    • Endosaccular aneurysm occlusion with Guglielmi detachable coils for obstructive hydrocephalus caused by a large basilar tip ancurysm
    • Watanabe A, Imamura K, Ishii R. Endosaccular aneurysm occlusion with Guglielmi detachable coils for obstructive hydrocephalus caused by a large basilar tip ancurysm. J Neurosurg 1999;91:675-678
    • (1999) J Neurosurg , vol.91 , pp. 675-678
    • Watanabe, A.1    Imamura, K.2    Ishii, R.3
  • 2
    • 2942532186 scopus 로고    scopus 로고
    • Turn-back technique with use of a shaped microcatheter for superselective: Catheterization of arteries originating at acute angles
    • Kiyosue H, Matsumoto S, Hori Y, et al. Turn-back technique with use of a shaped microcatheter for superselective: catheterization of arteries originating at acute angles. J Vasc Interv Radiol 2004;15:641-643
    • (2004) J Vasc Interv Radiol , vol.15 , pp. 641-643
    • Kiyosue, H.1    Matsumoto, S.2    Hori, Y.3
  • 3
    • 2942635965 scopus 로고    scopus 로고
    • Distal-tip shape-consistency testing of steam-shaped microcatheters suitable for cerebral aneurysm coil placement
    • Abe T, Hirohata M, Tanaka N, et al. Distal-tip shape-consistency testing of steam-shaped microcatheters suitable for cerebral aneurysm coil placement AJNR Am J Neuroradiol 2004;25:1058-1061
    • (2004) AJNR Am J Neuroradiol , vol.25 , pp. 1058-1061
    • Abe, T.1    Hirohata, M.2    Tanaka, N.3
  • 4
    • 0036735720 scopus 로고    scopus 로고
    • Marker alignment for Guglielmi detachable coil embolization: Practical considerations
    • Kwon OK, Han MH. Marker alignment for Guglielmi detachable coil embolization: xpractical considerations. AJNR Am J Neuroradiol 2002;23:1276-1283
    • (2002) AJNR Am J Neuroradiol , vol.23 , pp. 1276-1283
    • Kwon, O.K.1    Han, M.H.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.