메뉴 건너뛰기




Volumn 29, Issue 5, 2008, Pages 430-436

Lethal activity of nonthermal plasma sterilization against microorganisms

Author keywords

[No Author keywords available]

Indexed keywords

BACTERIAL DNA; BACTERIAL PROTEIN; DISINFECTANT AGENT;

EID: 42549132409     PISSN: 0899823X     EISSN: None     Source Type: Journal    
DOI: 10.1086/588003     Document Type: Article
Times cited : (89)

References (22)
  • 1
    • 0031874972 scopus 로고    scopus 로고
    • Comparative evaluation of the sporicidal activity of new low-temperature sterilization technologies: Ethylene oxide, 2 plasma sterilization systems, and liquid peracetic acid
    • Rutala WA, Gergen MF, Weber DJ. Comparative evaluation of the sporicidal activity of new low-temperature sterilization technologies: ethylene oxide, 2 plasma sterilization systems, and liquid peracetic acid. Am J Infect Control 1998; 26:393-398.
    • (1998) Am J Infect Control , vol.26 , pp. 393-398
    • Rutala, W.A.1    Gergen, M.F.2    Weber, D.J.3
  • 2
    • 0033395397 scopus 로고    scopus 로고
    • Infection control: The role of disinfection and sterilization
    • Rutala WA, Weber DJ. Infection control: the role of disinfection and sterilization. J Hosp Infect 1999; 43(Suppl):S43-55.
    • (1999) J Hosp Infect , vol.43 , Issue.SUPPL.
    • Rutala, W.A.1    Weber, D.J.2
  • 3
    • 0032176559 scopus 로고    scopus 로고
    • Clinical effectiveness of low-temperature sterilization technologies
    • Rutala WA, Weber DJ. Clinical effectiveness of low-temperature sterilization technologies. Infect Control Hosp Epidemiol 1998; 19:798-804.
    • (1998) Infect Control Hosp Epidemiol , vol.19 , pp. 798-804
    • Rutala, W.A.1    Weber, D.J.2
  • 4
    • 0027603625 scopus 로고
    • Low-temperature sterilization using gas plasmas
    • Griffiths N. Low-temperature sterilization using gas plasmas. Med Device Technol 1993; 4:37-40.
    • (1993) Med Device Technol , vol.4 , pp. 37-40
    • Griffiths, N.1
  • 6
    • 0029858533 scopus 로고    scopus 로고
    • Changes in hospital practice
    • Alfa MJ. Changes in hospital practice. Biomed Instrum Technol 1996; 30:400-404.
    • (1996) Biomed Instrum Technol , vol.30 , pp. 400-404
    • Alfa, M.J.1
  • 7
    • 39049176599 scopus 로고    scopus 로고
    • New surgical instruments and sets bring sterilization challenges
    • Carlo A. New surgical instruments and sets bring sterilization challenges. Mater Manag Health Care 2006; 15:64.
    • (2006) Mater Manag Health Care , vol.15 , pp. 64
    • Carlo, A.1
  • 9
    • 0035845749 scopus 로고    scopus 로고
    • Low-temperature sterilization using gas plasmas: A review of the experiments and an analysis of the inactivation mechanisms
    • Moisan M, Barbeau J, Moreau S, Pelletier J, Tabrizian M, Yahia LH. Low-temperature sterilization using gas plasmas: a review of the experiments and an analysis of the inactivation mechanisms. Int J Pharm 2001; 226:1-21.
    • (2001) Int J Pharm , vol.226 , pp. 1-21
    • Moisan, M.1    Barbeau, J.2    Moreau, S.3    Pelletier, J.4    Tabrizian, M.5    Yahia, L.H.6
  • 11
    • 2142714435 scopus 로고    scopus 로고
    • Evaluation of the roles of reactive species, heat, and UV radiation in the inactivation of bacterial cells by air plasmas at atmospheric pressure
    • Laroussi M, Leipold F. Evaluation of the roles of reactive species, heat, and UV radiation in the inactivation of bacterial cells by air plasmas at atmospheric pressure. Int J Mass Spectrom 2004; 233: 81-86.
    • (2004) Int J Mass Spectrom , vol.233 , pp. 81-86
    • Laroussi, M.1    Leipold, F.2
  • 12
    • 33746085676 scopus 로고    scopus 로고
    • A complementary sterilisation strategy using cold atmospheric plasmas
    • Kong M. A complementary sterilisation strategy using cold atmospheric plasmas. Med Device Technol 2006; 17:26-28.
    • (2006) Med Device Technol , vol.17 , pp. 26-28
    • Kong, M.1
  • 13
    • 0344835814 scopus 로고    scopus 로고
    • Gas-plasma sterilization: Relative efficacy of the hydrogen peroxide phase compared with that of the plasma phase
    • Krebs MC, Becasse P, Verjat D, Darbord JC. Gas-plasma sterilization: relative efficacy of the hydrogen peroxide phase compared with that of the plasma phase. Int J Pharm 1998; 160:75-81.
    • (1998) Int J Pharm , vol.160 , pp. 75-81
    • Krebs, M.C.1    Becasse, P.2    Verjat, D.3    Darbord, J.C.4
  • 14
    • 0035470244 scopus 로고    scopus 로고
    • Plasma sterilization: A review of parameters, mechanisms, and limitations
    • Lerouge S, Wertheimer MR, Yahia LH. Plasma sterilization: a review of parameters, mechanisms, and limitations. Plasmas Polym 2001; 6:175-188.
    • (2001) Plasmas Polym , vol.6 , pp. 175-188
    • Lerouge, S.1    Wertheimer, M.R.2    Yahia, L.H.3
  • 15
    • 0037275588 scopus 로고    scopus 로고
    • Features of sterilization using low-pressure DC-discharge hydrogen peroxide plasma
    • Soloshenko A, Tsiolko VV, Khomich VA, et al. Features of sterilization using low-pressure DC-discharge hydrogen peroxide plasma. IEEE Trans Plasma Sci 2002; 30:1440-1444.
    • (2002) IEEE Trans Plasma Sci , vol.30 , pp. 1440-1444
    • Soloshenko, A.1    Tsiolko, V.V.2    Khomich, V.A.3
  • 16
    • 0004135423 scopus 로고    scopus 로고
    • Treatment of surfaces
    • United States Patent No. 3,383,163. Patented May 14, 1968
    • Menashi WP. Treatment of surfaces. United States Patent No. 3,383,163. Patented May 14, 1968.
    • Menashi, W.P.1
  • 17
    • 42549131518 scopus 로고    scopus 로고
    • Biocidal properties of the ambient air plasma: Symposium on environmental, biological, and medical applications of microplasmas
    • October 6-8, Stevens Institute of Technology, Hoboken, NJ
    • Babko-Malyi S. Biocidal properties of the ambient air plasma: symposium on environmental, biological, and medical applications of microplasmas. In: Program of 2nd International Workshop on Microplasmas; October 6-8, 2004; Stevens Institute of Technology, Hoboken, NJ.
    • (2004) Program of 2nd International Workshop on Microplasmas
    • Babko-Malyi, S.1
  • 18
    • 42549113973 scopus 로고    scopus 로고
    • ISO 14937:2000 Sterilization of health care products - General requirements for characterization of a sterilizing agent and the development, validation and routine control of a sterilization process for medical devices, 2nd ed. Doc. 198 N762.
    • ISO 14937:2000 Sterilization of health care products - General requirements for characterization of a sterilizing agent and the development, validation and routine control of a sterilization process for medical devices, 2nd ed. Doc. 198 N762.
  • 19
    • 0004075854 scopus 로고    scopus 로고
    • Sterilization of healthcare products - Biological indicators - Guidance for the selection, use, and interpretation of results
    • ISO 14161
    • ISO 14161:2000 Sterilization of healthcare products - Biological indicators - Guidance for the selection, use, and interpretation of results.
    • (2000)
  • 20
    • 33747840685 scopus 로고    scopus 로고
    • Bactericidal action of the reactive species produced by gas-discharge nonthermal plasma at atmospheric pressure: A review
    • Gaunt L, Beggs C, Georghiou G. Bactericidal action of the reactive species produced by gas-discharge nonthermal plasma at atmospheric pressure: a review. IEEE Trans Plasma Sci 2006; 34:1257-1269.
    • (2006) IEEE Trans Plasma Sci , vol.34 , pp. 1257-1269
    • Gaunt, L.1    Beggs, C.2    Georghiou, G.3
  • 21
    • 0032969092 scopus 로고    scopus 로고
    • Bacillus subtilis spore coat
    • Driks A. Bacillus subtilis spore coat. Microbiol Mol Biol Rev 1999; 63:1-20.
    • (1999) Microbiol Mol Biol Rev , vol.63 , pp. 1-20
    • Driks, A.1
  • 22
    • 11244288040 scopus 로고    scopus 로고
    • Bacterial inactivation in open air by afterglow plume emitted from a grounded hollow slot electrode
    • Sharma A, Pruden A, Yu Z, Collins G. Bacterial inactivation in open air by afterglow plume emitted from a grounded hollow slot electrode. Environ Sci Technol 2005; 39:339-344.
    • (2005) Environ Sci Technol , vol.39 , pp. 339-344
    • Sharma, A.1    Pruden, A.2    Yu, Z.3    Collins, G.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.