메뉴 건너뛰기




Volumn 19, Issue 2, 2008, Pages

A novel interface circuit for grounded capacitive sensors with feedforward-based active shielding

Author keywords

Active shielding; Capacitive sensor; Relaxation oscillator; Sensor electronic interface

Indexed keywords

CALIBRATION; ELECTRIC POWER SYSTEM INTERCONNECTION; ERROR ANALYSIS; NONLINEAR ANALYSIS;

EID: 42549096514     PISSN: 09570233     EISSN: 13616501     Source Type: Journal    
DOI: 10.1088/0957-0233/19/2/025202     Document Type: Article
Times cited : (34)

References (16)
  • 1
    • 0027611922 scopus 로고
    • Capacitive sensors: When and how to use them
    • Puers R 1993 Capacitive sensors: when and how to use them Sensors Actuators A 37-38 93-105
    • (1993) Sensors Actuators , vol.37-38 , Issue.1 , pp. 93-105
    • Puers, R.1
  • 3
    • 0000618993 scopus 로고
    • Electronic transducers for industrial measurement of low value capacitances
    • Huang S M, Stott A L, Green R G and Beck M S 1988 Electronic transducers for industrial measurement of low value capacitances J. Phys. E: Sci. Instrum. 21 242-50
    • (1988) J. Phys. E: Sci. Instrum. , vol.21 , Issue.3 , pp. 242-250
    • Huang, S.M.1    Stott, A.L.2    Green, R.G.3    Beck, M.S.4
  • 4
    • 0027559840 scopus 로고
    • High-accuracy measurement techniques for capacitance transducers
    • Marioli D, Sardini E and Taroni A 1993 High-accuracy measurement techniques for capacitance transducers Meas. Sci. Technol. 4 337-43
    • (1993) Meas. Sci. Technol. , vol.4 , Issue.3 , pp. 337-343
    • Marioli, D.1    Sardini, E.2    Taroni, A.3
  • 5
    • 0020826644 scopus 로고
    • A water-level sensor using a capacitance to frequency converter
    • Ross P J 1983 A water-level sensor using a capacitance to frequency converter J. Phys. E: Sci. Instrum. 16 827-8
    • (1983) J. Phys. E: Sci. Instrum. , vol.16 , Issue.9 , pp. 827-828
    • Ross, P.J.1
  • 6
    • 33744544474 scopus 로고    scopus 로고
    • A low-cost noncontact capacitance-type level transducer for a conducting liquid
    • Bera S C, Ray J K and Chattopadhyay S 2006 A low-cost noncontact capacitance-type level transducer for a conducting liquid IEEE Trans. Instrum. Meas. 55 778-86
    • (2006) IEEE Trans. Instrum. Meas. , vol.55 , Issue.3 , pp. 778-786
    • Bera, S.C.1    Ray, J.K.2    Chattopadhyay, S.3
  • 8
    • 0024684101 scopus 로고
    • A switched-capacitor interface for capacitive sensors with wide dynamic range
    • Kondo K and Watanabe K 1989 A switched-capacitor interface for capacitive sensors with wide dynamic range IEEE Trans. Instrum. Meas. 38 736-9
    • (1989) IEEE Trans. Instrum. Meas. , vol.38 , Issue.3 , pp. 736-739
    • Kondo, K.1    Watanabe, K.2
  • 9
    • 0032024185 scopus 로고    scopus 로고
    • Low-cost, high-precision measurement system for capacitive sensors
    • Kolle C and Leary P O 1998 Low-cost, high-precision measurement system for capacitive sensors Meas. Sci. Technol. 9 510-7
    • (1998) Meas. Sci. Technol. , vol.9 , Issue.3 , pp. 510-517
    • Kolle, C.1    Leary, P.O.2
  • 10
    • 0030127110 scopus 로고    scopus 로고
    • A novel low-cost capacitive-sensor interface
    • Goes F M L and Meijer G C M 1996 A novel low-cost capacitive-sensor interface IEEE Trans. Instrum. Meas. 45 536-40
    • (1996) IEEE Trans. Instrum. Meas. , vol.45 , Issue.2 , pp. 536-540
    • Goes, F.M.L.1    Meijer, G.C.M.2
  • 11
    • 0036826018 scopus 로고    scopus 로고
    • An accurate interface for capacitive sensors
    • Li X and Meijer G C M 2002 An accurate interface for capacitive sensors IEEE Trans. Instrum. Meas. 51 935-9
    • (2002) IEEE Trans. Instrum. Meas. , vol.51 , Issue.5 , pp. 935-939
    • Li, X.1    Meijer, G.C.M.2
  • 12
    • 26844460048 scopus 로고    scopus 로고
    • On the optimization of ultra low power front-end interfaces for capacitive sensors
    • Bracke W, Merken P, Puers R and Van Hoof C 2005 On the optimization of ultra low power front-end interfaces for capacitive sensors Sensors Actuators A 117 273-85
    • (2005) Sensors Actuators , vol.117 , Issue.2 , pp. 273-285
    • Bracke, W.1    Merken, P.2    Puers, R.3    Van Hoof, C.4
  • 14
    • 33846112155 scopus 로고    scopus 로고
    • Stability and accuracy of active shielding for grounded capacitive sensors
    • Reverter F, Li X and Meijer G C M 2006 Stability and accuracy of active shielding for grounded capacitive sensors Meas. Sci. Technol. 17 2884-90
    • (2006) Meas. Sci. Technol. , vol.17 , Issue.11 , pp. 2884-2890
    • Reverter, F.1    Li, X.2    Meijer, G.C.M.3
  • 16
    • 34347237831 scopus 로고    scopus 로고
    • Liquid-level measurement system based on a remote grounded capacitive sensor
    • Reverter F, Li X and Meijer G C M 2007 Liquid-level measurement system based on a remote grounded capacitive sensor Sensors Actuators A 138 1-8
    • (2007) Sensors Actuators , vol.138 , Issue.1 , pp. 1-8
    • Reverter, F.1    Li, X.2    Meijer, G.C.M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.