메뉴 건너뛰기




Volumn 62, Issue 3 SUPPL. 1, 2008, Pages

Compensation of geometric distortion effects on intraoperative magnetic resonance imaging for enhanced visualization in image-guided neurosurgery

Author keywords

Image guided neurosurgery; Magnetic resonance image geometric distortion; Multimodal registration; Nonrigid registration

Indexed keywords

ADULT; ALGORITHM; ARTICLE; ASTROCYTOMA; BRAIN TUMOR; CLINICAL ARTICLE; DIAGNOSTIC ACCURACY; FEMALE; GEOMETRY; GLIOBLASTOMA; HUMAN; IMAGE ANALYSIS; IMAGE INTENSIFIER; IMAGE PROCESSING; IMAGE QUALITY; IMAGING SYSTEM; INTERVENTIONAL MAGNETIC RESONANCE IMAGING; MALE; NEUROSURGERY; OLIGODENDROGLIOMA; PEROPERATIVE ECHOGRAPHY; PILOT STUDY; PREOPERATIVE EVALUATION; PRIORITY JOURNAL; PROSPECTIVE STUDY; STATISTICAL SIGNIFICANCE; THREE DIMENSIONAL IMAGING;

EID: 42449094587     PISSN: 0148396X     EISSN: None     Source Type: Journal    
DOI: 10.1227/01.neu.0000317395.08466.e6     Document Type: Article
Times cited : (19)

References (40)
  • 4
    • 0036129398 scopus 로고    scopus 로고
    • Achieving gross total resection of brain tumors: Intraoperative MR imaging can make a big difference
    • Bradley WG: Achieving gross total resection of brain tumors: Intraoperative MR imaging can make a big difference. AJNR Am J Neuroradiol 23:248-349, 2002.
    • (2002) AJNR Am J Neuroradiol , vol.23 , pp. 248-349
    • Bradley, W.G.1
  • 10
    • 0032173370 scopus 로고    scopus 로고
    • Validation of object-induced MR distortion correction for frameless stereotactic neurosurgery
    • Dean D, Kamath J, Duerk JL, Ganz E: Validation of object-induced MR distortion correction for frameless stereotactic neurosurgery. IEEE Trans Med Imaging 17:810-816, 1998.
    • (1998) IEEE Trans Med Imaging , vol.17 , pp. 810-816
    • Dean, D.1    Kamath, J.2    Duerk, J.L.3    Ganz, E.4
  • 11
    • 17144430524 scopus 로고    scopus 로고
    • A complete distortion correction for MR images: I. Gradient warp correction
    • Doran SJ, Charles-Edwards L, Reinsberg SA, Leach MO: A complete distortion correction for MR images: I. Gradient warp correction. Phys Med Biol 50:1342-1361, 2005.
    • (2005) Phys Med Biol , vol.50 , pp. 1342-1361
    • Doran, S.J.1    Charles-Edwards, L.2    Reinsberg, S.A.3    Leach, M.O.4
  • 13
    • 1842483311 scopus 로고    scopus 로고
    • Preoperative blood oxygen level-dependent functional magnetic resonance imaging in patients with primary brain tumors: Clinical application and outcome
    • Haberg A, Kvistad KA, Unsgard G, Haraldseth O: Preoperative blood oxygen level-dependent functional magnetic resonance imaging in patients with primary brain tumors: Clinical application and outcome. Neurosurgery 54:902-914, 2004.
    • (2004) Neurosurgery , vol.54 , pp. 902-914
    • Haberg, A.1    Kvistad, K.A.2    Unsgard, G.3    Haraldseth, O.4
  • 14
    • 0026622949 scopus 로고
    • Intensity artifacts in MRI caused by gradient switching in an animal-size NMR magnet
    • Hughes DG, Robertson S, Allen PS: Intensity artifacts in MRI caused by gradient switching in an animal-size NMR magnet. Magn Reson Med 25:167-179, 1992.
    • (1992) Magn Reson Med , vol.25 , pp. 167-179
    • Hughes, D.G.1    Robertson, S.2    Allen, P.S.3
  • 15
    • 0035159014 scopus 로고    scopus 로고
    • Integration of interventional MRI with computer-assisted surgery
    • Jolesz FA, Nabavi A, Kikinis R: Integration of interventional MRI with computer-assisted surgery. J Magn Reson Imaging 13:69-77, 2001.
    • (2001) J Magn Reson Imaging , vol.13 , pp. 69-77
    • Jolesz, F.A.1    Nabavi, A.2    Kikinis, R.3
  • 16
    • 20844448551 scopus 로고    scopus 로고
    • Functional magnetic resonance imaging integrated neuronavigation: Correlation between lesion-to-motor cortex distance and outcome
    • Krishnan R, Raabe A, Hattingen E, Szelenyi A, Yahya H, Hermann E, Zimmermann M, Seifert V: Functional magnetic resonance imaging integrated neuronavigation: Correlation between lesion-to-motor cortex distance and outcome. Neurosurgery 55:904-914, 2004.
    • (2004) Neurosurgery , vol.55 , pp. 904-914
    • Krishnan, R.1    Raabe, A.2    Hattingen, E.3    Szelenyi, A.4    Yahya, H.5    Hermann, E.6    Zimmermann, M.7    Seifert, V.8
  • 17
    • 0032992683 scopus 로고    scopus 로고
    • MRI geometric distortion: A simple approach to correcting the effects of non-linear gradient fields
    • Langlois S, Desvignes M, Constans JM, Revenu M: MRI geometric distortion: A simple approach to correcting the effects of non-linear gradient fields. J Magn Reson Imaging 9:821-831, 1999.
    • (1999) J Magn Reson Imaging , vol.9 , pp. 821-831
    • Langlois, S.1    Desvignes, M.2    Constans, J.M.3    Revenu, M.4
  • 19
    • 25444484955 scopus 로고    scopus 로고
    • Characterization and correction of distortions in stereotactic magnetic resonance imaging for bilateral subthalamic stimulation in Parkinson disease
    • Menuel C, Garnero L, Bardinet E, Poupon F, Phalippou D, Dormont D: Characterization and correction of distortions in stereotactic magnetic resonance imaging for bilateral subthalamic stimulation in Parkinson disease. J Neurosurg 103:256-266, 2005.
    • (2005) J Neurosurg , vol.103 , pp. 256-266
    • Menuel, C.1    Garnero, L.2    Bardinet, E.3    Poupon, F.4    Phalippou, D.5    Dormont, D.6
  • 23
    • 10644265259 scopus 로고    scopus 로고
    • Intraoperative diffusion-tensor MR imaging: Shifting of white matter tracts during neurosurgical procedure: Initial experience
    • Nimsky C, Ganslandt O, Hastreiter P, Wang R, Benner R, Sorensen AG, Fahlbusch R: Intraoperative diffusion-tensor MR imaging: Shifting of white matter tracts during neurosurgical procedure: Initial experience. Radiology 234:218-225, 2005.
    • (2005) Radiology , vol.234 , pp. 218-225
    • Nimsky, C.1    Ganslandt, O.2    Hastreiter, P.3    Wang, R.4    Benner, R.5    Sorensen, A.G.6    Fahlbusch, R.7
  • 24
    • 1842422614 scopus 로고    scopus 로고
    • Effects of geometric distortion in 0.2T MRI on radiotherapy treatment planning of prostate cancer
    • Petersch B, Bogner J, Fransson A, Lorang T, Potter R: Effects of geometric distortion in 0.2T MRI on radiotherapy treatment planning of prostate cancer. Radiother Oncol 71:55-64, 2004.
    • (2004) Radiother Oncol , vol.71 , pp. 55-64
    • Petersch, B.1    Bogner, J.2    Fransson, A.3    Lorang, T.4    Potter, R.5
  • 26
    • 0026740215 scopus 로고
    • Direct imaging of magnetic field gradients by group spin-echo selection
    • Posse S: Direct imaging of magnetic field gradients by group spin-echo selection. Magn Reson Med 25:12-29, 1992.
    • (1992) Magn Reson Med , vol.25 , pp. 12-29
    • Posse, S.1
  • 28
    • 0030013529 scopus 로고    scopus 로고
    • The role of magnetic susceptibility in magnetic resonance imaging: MRI magnetic compatibility of the first and second kinds
    • Schenck JF: The role of magnetic susceptibility in magnetic resonance imaging: MRI magnetic compatibility of the first and second kinds. Med Phys 23:815-850, 1996.
    • (1996) Med Phys , vol.23 , pp. 815-850
    • Schenck, J.F.1
  • 30
    • 21244506736 scopus 로고    scopus 로고
    • Correction of MR image distortions induced by metallic objects using a 3D cubic B-spline basis set: Application to stereotactic surgical planning
    • Skare S, Andersson JL: Correction of MR image distortions induced by metallic objects using a 3D cubic B-spline basis set: Application to stereotactic surgical planning. Magn Reson Med 54:169-181, 2005.
    • (2005) Magn Reson Med , vol.54 , pp. 169-181
    • Skare, S.1    Andersson, J.L.2
  • 31
    • 0036828879 scopus 로고    scopus 로고
    • Fast robust automated brain extraction
    • Smith SM: Fast robust automated brain extraction. Hum Brain Mapp 17:143-155, 2002.
    • (2002) Hum Brain Mapp , vol.17 , pp. 143-155
    • Smith, S.M.1
  • 35
    • 0030030322 scopus 로고    scopus 로고
    • A phantom study to assess the accuracy of stereotactic localization, using T1 weighted magnetic resonance imaging with the Leksell stereotactic system
    • Walton L, Hampshire A, Forster DMC, Kemeny AA: A phantom study to assess the accuracy of stereotactic localization, using T1 weighted magnetic resonance imaging with the Leksell stereotactic system. Neurosurgery 38:170-178, 1996.
    • (1996) Neurosurgery , vol.38 , pp. 170-178
    • Walton, L.1    Hampshire, A.2    Forster, D.M.C.3    Kemeny, A.A.4
  • 36
    • 10644266195 scopus 로고    scopus 로고
    • Geometric distortion in clinical MRI systems Part I: Evaluation using a 3D phantom
    • Wang D, Strugnell W, Cowin G, Doddrell DM, Slaughter R: Geometric distortion in clinical MRI systems Part I: Evaluation using a 3D phantom. Magn Reson Imaging 22:1211-1221, 2004.
    • (2004) Magn Reson Imaging , vol.22 , pp. 1211-1221
    • Wang, D.1    Strugnell, W.2    Cowin, G.3    Doddrell, D.M.4    Slaughter, R.5
  • 37
    • 10644296409 scopus 로고    scopus 로고
    • Geometric distortion in clinical MRI systems Part II: Correction using a 3D phantom
    • Wang D, Strugnell W, Cowin G, Doddrell DM, Slaughter R: Geometric distortion in clinical MRI systems Part II: Correction using a 3D phantom. Magn Reson Imaging 22:1223-1232, 2004.
    • (2004) Magn Reson Imaging , vol.22 , pp. 1223-1232
    • Wang, D.1    Strugnell, W.2    Cowin, G.3    Doddrell, D.M.4    Slaughter, R.5
  • 38
    • 0032446659 scopus 로고    scopus 로고
    • Magnetic resonance spectroscopic imaging for visualization and correction of distortions in MRI: High precision applications in neurosurgery
    • Weis J, Ericsson A, Silander HC, Hemmingsson A: Magnetic resonance spectroscopic imaging for visualization and correction of distortions in MRI: High precision applications in neurosurgery. Magn Reson Imaging 16:1265-1272, 1998.
    • (1998) Magn Reson Imaging , vol.16 , pp. 1265-1272
    • Weis, J.1    Ericsson, A.2    Silander, H.C.3    Hemmingsson, A.4
  • 39
    • 0034095527 scopus 로고    scopus 로고
    • Clinical evaluation and follow up results for intraoperative magnetic resonance imaging in neurosurgery
    • Wirtz CR, Knauth M, Staubert A, Bonsanto MM, Sartor K, Kunze S, Tronnier VM: Clinical evaluation and follow up results for intraoperative magnetic resonance imaging in neurosurgery. Neurosurgery 46:1120-1122, 2000.
    • (2000) Neurosurgery , vol.46 , pp. 1120-1122
    • Wirtz, C.R.1    Knauth, M.2    Staubert, A.3    Bonsanto, M.M.4    Sartor, K.5    Kunze, S.6    Tronnier, V.M.7
  • 40
    • 0029303734 scopus 로고
    • Empirical compensation function for eddy current effects in pulsed field gradient nuclear magnetic resonance experiments
    • Zhu XX, Macdonald PM: Empirical compensation function for eddy current effects in pulsed field gradient nuclear magnetic resonance experiments. Solid State Magn Reson 4:217-227, 1995.
    • (1995) Solid State Magn Reson , vol.4 , pp. 217-227
    • Zhu, X.X.1    Macdonald, P.M.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.