메뉴 건너뛰기




Volumn 170, Issue 1, 2004, Pages 79-87

Quantitative measurement of temperature by proton resonance frequency shift at low field: A general method to correct non-linear spatial and temporal phase deformations

Author keywords

Food; Low field scanner; MRI; Phase shift; Thermometry

Indexed keywords

DISTILLATION; GELS; MAGNETIC FIELDS; MAGNETIC RESONANCE IMAGING; MATHEMATICAL MODELS; PROTONS; SPATIAL VARIABLES CONTROL; THERMOCOUPLES; WATER;

EID: 4243194654     PISSN: 10907807     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.jmr.2004.06.001     Document Type: Article
Times cited : (8)

References (16)
  • 6
    • 0033988069 scopus 로고    scopus 로고
    • MRI mapping of temperature distribution induced in food by microwave heating
    • Nott K.P., Hall L.D., Bows J.R., Hale M., Patrick M.L. MRI mapping of temperature distribution induced in food by microwave heating. Magn. Reson. Imaging. 18:2000;69-79.
    • (2000) Magn. Reson. Imaging , vol.18 , pp. 69-79
    • Nott, K.P.1    Hall, L.D.2    Bows, J.R.3    Hale, M.4    Patrick, M.L.5
  • 7
    • 36849111386 scopus 로고
    • Proton resonance shift of water in the gas and liquid states
    • Hindman J.C. Proton resonance shift of water in the gas and liquid states. J. Chem. Phys. 44:1966;4582-4592.
    • (1966) J. Chem. Phys. , vol.44 , pp. 4582-4592
    • Hindman, J.C.1
  • 9
    • 0037542561 scopus 로고    scopus 로고
    • Accurate and fast temperature mapping during ohmic heating using proton resonance frequency shift MRI thermometry
    • Ye X.F., Ruan R., Chen P., Chang K.H., Ning K., Taub I.A., Doona C. Accurate and fast temperature mapping during ohmic heating using proton resonance frequency shift MRI thermometry. J. Food Eng. 59:2003;143-150.
    • (2003) J. Food Eng. , vol.59 , pp. 143-150
    • Ye, X.F.1    Ruan, R.2    Chen, P.3    Chang, K.H.4    Ning, K.5    Taub, I.A.6    Doona, C.7
  • 10
    • 33744607266 scopus 로고
    • The proton resonance frequency shift method compared with molecular diffusion for quantitative measurement of two dimensional time dependent temperature distribution in a phantom
    • DePoorter J., DeWagner C., DeDeene Y., Thomsen C., Stahlberg F., Achten E. The proton resonance frequency shift method compared with molecular diffusion for quantitative measurement of two dimensional time dependent temperature distribution in a phantom. J. Magn. Reson. 103:1994;234-241.
    • (1994) J. Magn. Reson. , vol.103 , pp. 234-241
    • Depoorter, J.1    Dewagner, C.2    Dedeene, Y.3    Thomsen, C.4    Stahlberg, F.5    Achten, E.6
  • 13
    • 0037307494 scopus 로고    scopus 로고
    • Variation correction algorithm: Analysis of phase suppression and thermal profile fidelity for proton frequency magnetic resonance thermometry at 0.2 T
    • Barkauskas K.J., Lewin J.S., Duerk J.L. Variation correction algorithm: analysis of phase suppression and thermal profile fidelity for proton frequency magnetic resonance thermometry at 0.2. T J. Magn. Reson. Imaging. 17:2003;227-240.
    • (2003) J. Magn. Reson. Imaging , vol.17 , pp. 227-240
    • Barkauskas, K.J.1    Lewin, J.S.2    Duerk, J.L.3
  • 14
    • 33646435157 scopus 로고    scopus 로고
    • Déroulement de phase: Applicationàla correction de distorsions géométriques en IRM
    • Desvignes M., Langlois S., Constans J.M., Revenu M. Déroulement de phase: applicationàla correction de distorsions géométriques en IRM. Traitement du Signal. 17:2000;313-324.
    • (2000) Traitement du Signal , vol.17 , pp. 313-324
    • Desvignes, M.1    Langlois, S.2    Constans, J.M.3    Revenu, M.4
  • 15
    • 0033962907 scopus 로고    scopus 로고
    • Proton-resonance frequency shift MR thermometry is affected by changes in the electrical conductivity of tissue
    • Peters R.D., Henkelman R.M. Proton-resonance frequency shift MR thermometry is affected by changes in the electrical conductivity of tissue. Magn. Reson. Med. 43:2000;62-71.
    • (2000) Magn. Reson. Med. , vol.43 , pp. 62-71
    • Peters, R.D.1    Henkelman, R.M.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.