메뉴 건너뛰기




Volumn 28, Issue 2, 2008, Pages 174-182

The clinical usefulness of peritoneal dialysis fluids with neural pH and low glucose degradation product concentration: An open randomized prospective trial

Author keywords

Biocompatibility; CA125; Glucose degradation products; Neutral pH; Peritoneal function

Indexed keywords

CA 125 ANTIGEN; CREATINE; GLUCOSE DEGRADATION PRODUCT; PERITONEAL DIALYSIS FLUID; UREA;

EID: 42349109993     PISSN: 08968608     EISSN: None     Source Type: Journal    
DOI: 10.1177/089686080802800214     Document Type: Article
Times cited : (82)

References (37)
  • 1
    • 0032895140 scopus 로고    scopus 로고
    • Mortality and technique failure in patients starting chronic peritoneal dialysis: Results of the Netherlands Cooperative Study on the Adequacy of Dialysis. NECOSAD Study Group
    • Jager KJ, Merkus MP, Dekker FW, Boeschoten EW, Tijssen JG, Stevens P, et al. Mortality and technique failure in patients starting chronic peritoneal dialysis: results of the Netherlands Cooperative Study on the Adequacy of Dialysis. NECOSAD Study Group. Kidney Int 1999; 55:1476-85.
    • (1999) Kidney Int , vol.55 , pp. 1476-1485
    • Jager, K.J.1    Merkus, M.P.2    Dekker, F.W.3    Boeschoten, E.W.4    Tijssen, J.G.5    Stevens, P.6
  • 2
    • 1442359834 scopus 로고    scopus 로고
    • Peritoneal dialysis versus hemodialysis: A five-year comparison of survival and effects on the cardiovascular system, erythropoiesis, and calcium metabolism
    • Suzuki T, Kanno Y, Nakamoto H, Okada H, Sugahara S, Suzuki H. Peritoneal dialysis versus hemodialysis: a five-year comparison of survival and effects on the cardiovascular system, erythropoiesis, and calcium metabolism. Adv Perit Dial 2003; 19:148-54.
    • (2003) Adv Perit Dial , vol.19 , pp. 148-154
    • Suzuki, T.1    Kanno, Y.2    Nakamoto, H.3    Okada, H.4    Sugahara, S.5    Suzuki, H.6
  • 3
    • 0344514610 scopus 로고    scopus 로고
    • NECOSAD Study Group. Effect of starting with hemodialysis compared with peritoneal dialysis in patients new on dialysis treatment: A randomized controlled trial
    • Korevaar JC, Feith GW, Dekker FW, van Manen JG, Boeschoten EW, Bossuyt PM, et al; NECOSAD Study Group. Effect of starting with hemodialysis compared with peritoneal dialysis in patients new on dialysis treatment: a randomized controlled trial. Kidney Int 2003; 64:2222-8.
    • (2003) Kidney Int , vol.64 , pp. 2222-2228
    • Korevaar, J.C.1    Feith, G.W.2    Dekker, F.W.3    van Manen, J.G.4    Boeschoten, E.W.5    Bossuyt, P.M.6
  • 4
    • 0034749416 scopus 로고    scopus 로고
    • Trends in CAPD technique failure: Canada, 1981-1997
    • Schaubel DE, Blake PG, Fenton SSA. Trends in CAPD technique failure: Canada, 1981-1997. Perit Dial Int 2001; 21: 365-71.
    • (2001) Perit Dial Int , vol.21 , pp. 365-371
    • Schaubel, D.E.1    Blake, P.G.2    Fenton, S.S.A.3
  • 5
    • 33747091004 scopus 로고    scopus 로고
    • Is technique survival on peritoneal dialysis better in Japan?
    • Nakamoto H, Kawaguchi Y, Suzuki H. Is technique survival on peritoneal dialysis better in Japan? Perit Dial Int 2006; 26:136-43.
    • (2006) Perit Dial Int , vol.26 , pp. 136-143
    • Nakamoto, H.1    Kawaguchi, Y.2    Suzuki, H.3
  • 6
    • 0025030632 scopus 로고
    • Peritoneal transport in CAPD patients with permanent loss of ultrafiltration capacity
    • Heimbürger O, Waniewski J, Werynski A, Tranaeus A, Lindholm B. Peritoneal transport in CAPD patients with permanent loss of ultrafiltration capacity. Kidney Int 1990; 38:495-506.
    • (1990) Kidney Int , vol.38 , pp. 495-506
    • Heimbürger, O.1    Waniewski, J.2    Werynski, A.3    Tranaeus, A.4    Lindholm, B.5
  • 7
    • 1642585655 scopus 로고    scopus 로고
    • Alterations in water and solute transport with time on peritoneal dialysis
    • Heimburger O, Wang T, Lindholm B. Alterations in water and solute transport with time on peritoneal dialysis. Perit Dial Int 1999; 19 (Suppl 2):S83-90.
    • (1999) Perit Dial Int , vol.19 , Issue.SUPPL. 2
    • Heimburger, O.1    Wang, T.2    Lindholm, B.3
  • 8
    • 0025875648 scopus 로고
    • Functional characteristics of the peritoneal membrane in long-term continuous ambulatory peritoneal dialysis
    • Struijk DG, Krediet RT, Koomen GC, Hoek FJ, Boeschoten EW, vd Reijden HJ, et al. Functional characteristics of the peritoneal membrane in long-term continuous ambulatory peritoneal dialysis. Nephron 1991; 59:213-20.
    • (1991) Nephron , vol.59 , pp. 213-220
    • Struijk, D.G.1    Krediet, R.T.2    Koomen, G.C.3    Hoek, F.J.4    Boeschoten, E.W.5    vd Reijden, H.J.6
  • 10
    • 0030012242 scopus 로고    scopus 로고
    • Longitudinal changes in peritoneal kinetics: The effects of peritoneal dialysis and peritonitis
    • Davies SJ, Bryan J, Phillips L, Russell GI. Longitudinal changes in peritoneal kinetics: the effects of peritoneal dialysis and peritonitis. Nephrol Dial Transplant 1996; 11: 498-506.
    • (1996) Nephrol Dial Transplant , vol.11 , pp. 498-506
    • Davies, S.J.1    Bryan, J.2    Phillips, L.3    Russell, G.I.4
  • 12
    • 0035035682 scopus 로고    scopus 로고
    • Peritoneal glucose exposure and changes in membrane solute transport with time on peritoneal dialysis
    • Davies SJ, Philips L, Naish PF, Russell GI. Peritoneal glucose exposure and changes in membrane solute transport with time on peritoneal dialysis. J Am Soc Nephrol 2001; 12:1046-51.
    • (2001) J Am Soc Nephrol , vol.12 , pp. 1046-1051
    • Davies, S.J.1    Philips, L.2    Naish, P.F.3    Russell, G.I.4
  • 13
    • 0036158071 scopus 로고    scopus 로고
    • Peritoneal Biopsy Study Group. Morphologic changes in the peritoneal membrane of patients with renal disease
    • Williams JD, Craig KJ, Topley N, Von Ruhland C, Fallon M, Newman GR, et al.; Peritoneal Biopsy Study Group. Morphologic changes in the peritoneal membrane of patients with renal disease. J Am Soc Nephrol 2002; 13:470-9.
    • (2002) J Am Soc Nephrol , vol.13 , pp. 470-479
    • Williams, J.D.1    Craig, K.J.2    Topley, N.3    Von Ruhland, C.4    Fallon, M.5    Newman, G.R.6
  • 14
    • 0344874202 scopus 로고    scopus 로고
    • Biopsy Registry Study Group. The natural course of peritoneal membrane biology during peritoneal dialysis
    • Williams JD, Craig KJ, von Ruhland C, Topley N, Williams GT; Biopsy Registry Study Group. The natural course of peritoneal membrane biology during peritoneal dialysis. Kidney Int Suppl 2003; 88:S43-9.
    • (2003) Kidney Int Suppl , vol.88
    • Williams, J.D.1    Craig, K.J.2    von Ruhland, C.3    Topley, N.4    Williams, G.T.5
  • 15
    • 0032972996 scopus 로고    scopus 로고
    • Accumulation of advanced glycation end products in the peritoneal vasculature of continuous ambulatory peritoneal dialysis patients with low ultrafiltration
    • Honda K, Nitta K, Horita S, Yumura W, Nihei H, Nagai R, et al. Accumulation of advanced glycation end products in the peritoneal vasculature of continuous ambulatory peritoneal dialysis patients with low ultrafiltration. Nephrol Dial Transplant 1999; 14:1541-9.
    • (1999) Nephrol Dial Transplant , vol.14 , pp. 1541-1549
    • Honda, K.1    Nitta, K.2    Horita, S.3    Yumura, W.4    Nihei, H.5    Nagai, R.6
  • 16
    • 0034816576 scopus 로고    scopus 로고
    • In vitro formation of N(epsilon)-(carboxymethyl)lysine and imidazotones under conditions similar to continuous ambulatory peritoneal dialysis
    • Tauer A, Knerr T, Niwa T, Schaub TP, Lage C, Passlick-Deetjen J, et al. In vitro formation of N(epsilon)-(carboxymethyl)lysine and imidazotones under conditions similar to continuous ambulatory peritoneal dialysis. Biochem Biophys Res Commun 2001; 280:1408-14.
    • (2001) Biochem Biophys Res Commun , vol.280 , pp. 1408-1414
    • Tauer, A.1    Knerr, T.2    Niwa, T.3    Schaub, T.P.4    Lage, C.5    Passlick-Deetjen, J.6
  • 18
    • 0037213451 scopus 로고    scopus 로고
    • Glucose degradation products in PD fluids: Do they disappear from the peritoneal cavity and enter the systemic circulation?
    • Zeier M, Schwenger V, Deppisch R, Haug U, Weigel K, Bahner U, et al. Glucose degradation products in PD fluids: do they disappear from the peritoneal cavity and enter the systemic circulation? Kidney Int 2003; 63:298-305.
    • (2003) Kidney Int , vol.63 , pp. 298-305
    • Zeier, M.1    Schwenger, V.2    Deppisch, R.3    Haug, U.4    Weigel, K.5    Bahner, U.6
  • 19
    • 0142187222 scopus 로고    scopus 로고
    • Glucose degradation products (GDP) retard remesothelialization independently of D-glucose concentration
    • Morgan LW, Wieslander A, Davies M, Horiuchi T, Ohta Y, Beavis MJ, et al. Glucose degradation products (GDP) retard remesothelialization independently of D-glucose concentration. Kidney Int 2003; 64:1854-66.
    • (2003) Kidney Int , vol.64 , pp. 1854-1866
    • Morgan, L.W.1    Wieslander, A.2    Davies, M.3    Horiuchi, T.4    Ohta, Y.5    Beavis, M.J.6
  • 20
    • 33645460972 scopus 로고    scopus 로고
    • Damage to the peritoneal membrane by glucose degradation products is mediated by the receptor for advanced glycation end-products
    • Schwenger V, Morath C, Salava A, Amann K, Seregin Y, Deppisch R, et al. Damage to the peritoneal membrane by glucose degradation products is mediated by the receptor for advanced glycation end-products. J Am Soc Nephrol 2006; 17:199-207.
    • (2006) J Am Soc Nephrol , vol.17 , pp. 199-207
    • Schwenger, V.1    Morath, C.2    Salava, A.3    Amann, K.4    Seregin, Y.5    Deppisch, R.6
  • 21
    • 4344696765 scopus 로고    scopus 로고
    • Long-term exposure to new peritoneal dialysis solutions: Effects on the peritoneal membrane
    • Mortier S, Faict D, Schalkwijk CG, Lameire NH, De Vriese AS. Long-term exposure to new peritoneal dialysis solutions: effects on the peritoneal membrane. Kidney Int 2004; 66:1257-65.
    • (2004) Kidney Int , vol.66 , pp. 1257-1265
    • Mortier, S.1    Faict, D.2    Schalkwijk, C.G.3    Lameire, N.H.4    De Vriese, A.S.5
  • 22
    • 21144438457 scopus 로고    scopus 로고
    • Superior patient survival for continuous ambulatory peritoneal dialysis patients treated with a peritoneal dialysis fluid with neutral pH and low glucose degradation product concentration (Balance)
    • Lee HY, Park HC, Seo BJ, Do JY, Yun SR, Song HY, et al. Superior patient survival for continuous ambulatory peritoneal dialysis patients treated with a peritoneal dialysis fluid with neutral pH and low glucose degradation product concentration (Balance). Perit Dial Int 2005; 25: 248-55.
    • (2005) Perit Dial Int , vol.25 , pp. 248-255
    • Lee, H.Y.1    Park, H.C.2    Seo, B.J.3    Do, J.Y.4    Yun, S.R.5    Song, H.Y.6
  • 23
    • 0024582188 scopus 로고
    • Clinical value of standardized equilibration tests in CAPD patients
    • Twardowski ZJ. Clinical value of standardized equilibration tests in CAPD patients. Blood Purif 1989; 7(2-3): 95-108.
    • (1989) Blood Purif , vol.7 , Issue.2-3 , pp. 95-108
    • Twardowski, Z.J.1
  • 24
    • 0035162741 scopus 로고    scopus 로고
    • Long-term clinical effects of a peritoneal dialysis fluid with Less glucose degradation products
    • Rippe B, Simonsen O, Heimburger O, Christensson A, Haraldsson B, Stelin G, et al. Long-term clinical effects of a peritoneal dialysis fluid with Less glucose degradation products. Kidney Int 2001; 59:348-57.
    • (2001) Kidney Int , vol.59 , pp. 348-357
    • Rippe, B.1    Simonsen, O.2    Heimburger, O.3    Christensson, A.4    Haraldsson, B.5    Stelin, G.6
  • 25
    • 42349088242 scopus 로고    scopus 로고
    • Long-term results with low glucose degradation product content in peritoneal dialysis fluids
    • Rippe B, Wieslander A, Musi B. Long-term results with low glucose degradation product content in peritoneal dialysis fluids. Contrib Nephrol 2003; 140:47-55.
    • (2003) Contrib Nephrol , vol.140 , pp. 47-55
    • Rippe, B.1    Wieslander, A.2    Musi, B.3
  • 26
    • 3042720430 scopus 로고    scopus 로고
    • Euro Balance Trial Group. The Euro-Balance Trial: The effect of a new biocompatible peritoneal dialysis fluid (balance) on the peritoneal membrane
    • Williams JD, Topley N, Craig KJ, Mackenzie RK, Pischetsrieder M, Lage C, et al.; Euro Balance Trial Group. The Euro-Balance Trial: the effect of a new biocompatible peritoneal dialysis fluid (balance) on the peritoneal membrane. Kidney Int 2004; 66:408-18.
    • (2004) Kidney Int , vol.66 , pp. 408-418
    • Williams, J.D.1    Topley, N.2    Craig, K.J.3    Mackenzie, R.K.4    Pischetsrieder, M.5    Lage, C.6
  • 27
    • 0033653329 scopus 로고    scopus 로고
    • A long-term study of a bicarbonate/lactate-based peritoneal dialysis solution-clinical benefits. The Bicarbonate/Lactate Study Group
    • Tranaeus A. A long-term study of a bicarbonate/lactate-based peritoneal dialysis solution-clinical benefits. The Bicarbonate/Lactate Study Group. Perit Dial Int 2000; 20: 516-23.
    • (2000) Perit Dial Int , vol.20 , pp. 516-523
    • Tranaeus, A.1
  • 29
    • 12644277373 scopus 로고    scopus 로고
    • Dialysate cell population and cancer antigen 125 in stable continuous ambulatory peritoneal dialysis patients: Their relationship with transport parameters
    • Lai KN, Lai KB, Szeto CC, Ho KK, Poon P, Lam CW, et al. Dialysate cell population and cancer antigen 125 in stable continuous ambulatory peritoneal dialysis patients: their relationship with transport parameters. Am J Kidney Dis 1997; 29:699-705.
    • (1997) Am J Kidney Dis , vol.29 , pp. 699-705
    • Lai, K.N.1    Lai, K.B.2    Szeto, C.C.3    Ho, K.K.4    Poon, P.5    Lam, C.W.6
  • 31
    • 0032949638 scopus 로고    scopus 로고
    • Dialysate CA125 levels in stable peritoneal dialysis patients
    • Okada T, Nakao T, Matsumoto H. Dialysate CA125 levels in stable peritoneal dialysis patients. Clin Nephrol 1999; 51: 65-6.
    • (1999) Clin Nephrol , vol.51 , pp. 65-66
    • Okada, T.1    Nakao, T.2    Matsumoto, H.3
  • 32
    • 0035071561 scopus 로고    scopus 로고
    • Bicarbonate/Lactate Study Group. Bicarbonate/Lactate-based peritoneal dialysis solution increases cancer antigen 125 and decreases hyaluronic acid levels
    • Jones S, Holmes CJ, Krediet RT, Mackenzie R, Faict D, Tranaeus A, et al.; Bicarbonate/Lactate Study Group. Bicarbonate/Lactate-based peritoneal dialysis solution increases cancer antigen 125 and decreases hyaluronic acid levels. Kidney Int 2001; 59:1529-38.
    • (2001) Kidney Int , vol.59 , pp. 1529-1538
    • Jones, S.1    Holmes, C.J.2    Krediet, R.T.3    Mackenzie, R.4    Faict, D.5    Tranaeus, A.6
  • 33
    • 0037639722 scopus 로고    scopus 로고
    • Effluent CA 125 concentration in chronic peritoneal dialysis patients: Influence of PD duration, peritoneal transport and PD regimen
    • Fussholler A, Grabensee B, Plum J. Effluent CA 125 concentration in chronic peritoneal dialysis patients: influence of PD duration, peritoneal transport and PD regimen. Kidney Blood Press Res 2003; 26:118-22.
    • (2003) Kidney Blood Press Res , vol.26 , pp. 118-122
    • Fussholler, A.1    Grabensee, B.2    Plum, J.3
  • 34
    • 0028850169 scopus 로고    scopus 로고
    • Hjelle JT, Miller-Hjelle MA, Dobbie JW. The biology of the mesothelium during peritoneal dialysis. Perit Dial Int 1995; 157 SuppQ:S13-22.
    • Hjelle JT, Miller-Hjelle MA, Dobbie JW. The biology of the mesothelium during peritoneal dialysis. Perit Dial Int 1995; 15(7 SuppQ:S13-22.
  • 35
    • 26144440717 scopus 로고    scopus 로고
    • PD: A biological membrane and a non-biological fluid
    • Jorres A. PD: a biological membrane and a non-biological fluid. Contrib Nephrol 2003; 140:1-9.
    • (2003) Contrib Nephrol , vol.140 , pp. 1-9
    • Jorres, A.1
  • 36
    • 16744362363 scopus 로고    scopus 로고
    • Bicarbonate/Lactate Study Group. Interleukin-6 levels decrease in effluent from patients dialyzed with bicarbonate/lactate-based peritonealdialysis solutions
    • Cooker LA, Luneburg P, Holmes CJ, Jones S, Topley N; Bicarbonate/Lactate Study Group. Interleukin-6 levels decrease in effluent from patients dialyzed with bicarbonate/lactate-based peritonealdialysis solutions. Perit Dial Int 2001; 21 (Suppl 3):5102-7.
    • (2001) Perit Dial Int , vol.21 , Issue.SUPPL. 3 , pp. 5102-5107
    • Cooker, L.A.1    Luneburg, P.2    Holmes, C.J.3    Jones, S.4    Topley, N.5
  • 37
    • 4344679569 scopus 로고    scopus 로고
    • Biocompatibility pattern of a bicarbonate/lactate-buffered peritoneal dialysis fluid in APD: A prospective, randomized study
    • Fusshoeller A, Plail M, Grabensee B, Plum J. Biocompatibility pattern of a bicarbonate/lactate-buffered peritoneal dialysis fluid in APD: a prospective, randomized study. Nephrol Dial Transplant 2004; 19:2101-6.
    • (2004) Nephrol Dial Transplant , vol.19 , pp. 2101-2106
    • Fusshoeller, A.1    Plail, M.2    Grabensee, B.3    Plum, J.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.