-
1
-
-
0141532034
-
Pediatric cataract surgery and intraocular lens implantation: Practice styles and preferences of the 2001 ASCRS and AAPOS memberships
-
Wilson M.E., Bartholomew L.R., and Trivedi R.H. Pediatric cataract surgery and intraocular lens implantation: Practice styles and preferences of the 2001 ASCRS and AAPOS memberships. J Cataract Refract Surg 29 (2003) 1811-1820
-
(2003)
J Cataract Refract Surg
, vol.29
, pp. 1811-1820
-
-
Wilson, M.E.1
Bartholomew, L.R.2
Trivedi, R.H.3
-
2
-
-
0030292547
-
Intraocular lens implantation: Has it become the standard of care for children?
-
Wilson M.E. Intraocular lens implantation: Has it become the standard of care for children?. Ophthalmology 103 (1996) 1719-1720
-
(1996)
Ophthalmology
, vol.103
, pp. 1719-1720
-
-
Wilson, M.E.1
-
4
-
-
10744221376
-
Intraocular lens implantation during infancy: Perceptions of parents and the American Association for Pediatric Ophthalmology and Strabismus members
-
Lambert S.R., Lynn M., Drews-Botsch C., DuBois L., Wilson M.E., Plager D.A., et al. Intraocular lens implantation during infancy: Perceptions of parents and the American Association for Pediatric Ophthalmology and Strabismus members. J AAPOS 7 (2003) 400-405
-
(2003)
J AAPOS
, vol.7
, pp. 400-405
-
-
Lambert, S.R.1
Lynn, M.2
Drews-Botsch, C.3
DuBois, L.4
Wilson, M.E.5
Plager, D.A.6
-
6
-
-
33846517354
-
Discrepancies between intraocular lens implant power prediction formulas in pediatric patients
-
Eibschitz-Tsimhoni M., Tsimhoni O., Archer S.M., and Del Monte M.A. Discrepancies between intraocular lens implant power prediction formulas in pediatric patients. Ophthalmology 114 (2007) 383-386
-
(2007)
Ophthalmology
, vol.114
, pp. 383-386
-
-
Eibschitz-Tsimhoni, M.1
Tsimhoni, O.2
Archer, S.M.3
Del Monte, M.A.4
-
7
-
-
0034108564
-
Errors in keratometry for intraocular lens implantation in infants
-
Mittelviefhaus H., and Gentner C. Errors in keratometry for intraocular lens implantation in infants. Ophthalmologe 97 (2000) 186-188
-
(2000)
Ophthalmologe
, vol.97
, pp. 186-188
-
-
Mittelviefhaus, H.1
Gentner, C.2
-
8
-
-
0023858680
-
Comparison of the SRK II formula and the other second generation formulas
-
Sanders D.R., Retzlaff J., and Kraff M.C. Comparison of the SRK II formula and the other second generation formulas. J Cataract Refract Surg 14 (1988) 136-141
-
(1988)
J Cataract Refract Surg
, vol.14
, pp. 136-141
-
-
Sanders, D.R.1
Retzlaff, J.2
Kraff, M.C.3
-
9
-
-
0018955290
-
Improvement of intraocular lens power calculation using empirical data
-
Sanders D.R., and Kraff M.C. Improvement of intraocular lens power calculation using empirical data. Am Intraocular Implant Soc J 6 (1980) 263-267
-
(1980)
Am Intraocular Implant Soc J
, vol.6
, pp. 263-267
-
-
Sanders, D.R.1
Kraff, M.C.2
-
10
-
-
0027442385
-
The Hoffer Q formula: A comparison of theoretical and regression formulas
-
ERRATA 1994;20:677
-
Hoffer K.J. The Hoffer Q formula: A comparison of theoretical and regression formulas. J Cataract Refract Surg 19 (1993) 700-712 ERRATA 1994;20:677
-
(1993)
J Cataract Refract Surg
, vol.19
, pp. 700-712
-
-
Hoffer, K.J.1
-
11
-
-
0023870818
-
A three-part system for refining intraocular lens power calculations
-
Holladay J.T., Prager T.C., Chandler T.Y., Musgrove K.H., Lewis J.W., and Ruis R.S. A three-part system for refining intraocular lens power calculations. J Cataract Refract Surg 14 (1988) 17-24
-
(1988)
J Cataract Refract Surg
, vol.14
, pp. 17-24
-
-
Holladay, J.T.1
Prager, T.C.2
Chandler, T.Y.3
Musgrove, K.H.4
Lewis, J.W.5
Ruis, R.S.6
-
12
-
-
0025315983
-
Development of the SRK/T intraocular lens implant power calculation formula
-
Retzlaff J., Sanders D.R., and Kraff M.C. Development of the SRK/T intraocular lens implant power calculation formula. J Cataract Refract Surg 16 (1990) 333-349
-
(1990)
J Cataract Refract Surg
, vol.16
, pp. 333-349
-
-
Retzlaff, J.1
Sanders, D.R.2
Kraff, M.C.3
-
14
-
-
41949085058
-
-
Optimized IOL Constants for the ZEISS IOLMaster. Accessed Aug 12, 2006
-
Optimized IOL Constants for the ZEISS IOLMaster. http://www.augenklinik.uni-wuerzburg.de/ulib/c1.htm Accessed Aug 12, 2006
-
-
-
-
15
-
-
0031948998
-
Intraocular lens calculator for childhood cataract
-
McClatchey S.K. Intraocular lens calculator for childhood cataract. J Cataract Refract Surg 24 (1998) 1125-1129
-
(1998)
J Cataract Refract Surg
, vol.24
, pp. 1125-1129
-
-
McClatchey, S.K.1
-
16
-
-
17444405294
-
Accuracy of intraocular lens calculations in infants and children undergoing cataract surgery
-
Neely D.E., Plager D.A., Borger S.M., and Golub R.L. Accuracy of intraocular lens calculations in infants and children undergoing cataract surgery. J AAPOS 9 (2005) 160-165
-
(2005)
J AAPOS
, vol.9
, pp. 160-165
-
-
Neely, D.E.1
Plager, D.A.2
Borger, S.M.3
Golub, R.L.4
-
17
-
-
33748586112
-
Intraocular Lens Power Calculations
-
Shammas H.J. (Ed), Slack, Thorofare (NJ)
-
Shammas H.J. Intraocular Lens Power Calculations. In: Shammas H.J. (Ed). The A-scan biometer (2004), Slack, Thorofare (NJ) 83-92
-
(2004)
The A-scan biometer
, pp. 83-92
-
-
Shammas, H.J.1
-
18
-
-
0030817812
-
Standardizing constants for ultrasonic biometry, keratometry, and intraocular lens power calculations
-
Holladay J.T. Standardizing constants for ultrasonic biometry, keratometry, and intraocular lens power calculations. J Cataract Refract Surg 23 (1997) 1356-1370
-
(1997)
J Cataract Refract Surg
, vol.23
, pp. 1356-1370
-
-
Holladay, J.T.1
-
19
-
-
0028108053
-
Ultrasound velocities for axial eye length measurement
-
Hoffer K.J. Ultrasound velocities for axial eye length measurement. J Cataract Refract Surg 20 (1994) 554-562
-
(1994)
J Cataract Refract Surg
, vol.20
, pp. 554-562
-
-
Hoffer, K.J.1
-
20
-
-
33748436360
-
Reliability and validity of the partial coherence interferometry for measurement of ocular axial length in children
-
[Epub 2005 Aug 12]
-
Hussin H.M., Spry P.G.D., Majid M.A., and Gouws P. Reliability and validity of the partial coherence interferometry for measurement of ocular axial length in children. Eye 20 (2006) 1021-1024 [Epub 2005 Aug 12]
-
(2006)
Eye
, vol.20
, pp. 1021-1024
-
-
Hussin, H.M.1
Spry, P.G.D.2
Majid, M.A.3
Gouws, P.4
-
21
-
-
0037587741
-
Highly precise eye length measurements in children aged 3 through 12 years
-
Quinn G.E., Francis E.L., and Nipper K.S. Highly precise eye length measurements in children aged 3 through 12 years. Arch Ophthalmol 121 (2003) 985-990
-
(2003)
Arch Ophthalmol
, vol.121
, pp. 985-990
-
-
Quinn, G.E.1
Francis, E.L.2
Nipper, K.S.3
-
22
-
-
41949100442
-
Cataract Surgery and Intraocular Lenses: A 21st-Century Perspective
-
JG F., and CL K. (Eds), American Academy of Ophthalmology, San Francisco (CA)
-
Hoffer K.J. Cataract Surgery and Intraocular Lenses: A 21st-Century Perspective. In: JG F., and CL K. (Eds). Intraocular lens calculations (2001), American Academy of Ophthalmology, San Francisco (CA)
-
(2001)
Intraocular lens calculations
-
-
Hoffer, K.J.1
|