메뉴 건너뛰기




Volumn 133, Issue 4, 2008, Pages 584-592

Corrosion of orthodontic appliances-should we care?

Author keywords

[No Author keywords available]

Indexed keywords

BIOMATERIAL; DENTAL ALLOY; NICKEL;

EID: 41849149703     PISSN: 08895406     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.ajodo.2007.03.021     Document Type: Review
Times cited : (175)

References (55)
  • 1
    • 29044445523 scopus 로고    scopus 로고
    • Corrosion resistance on three orthodontic brackets: a comparative study of three fluoride mouthwashes
    • Schiff N., Dalard F., Lissac M., Morgon L., and Grosgogeat B. Corrosion resistance on three orthodontic brackets: a comparative study of three fluoride mouthwashes. Eur J Orthod 27 (2005) 541-549
    • (2005) Eur J Orthod , vol.27 , pp. 541-549
    • Schiff, N.1    Dalard, F.2    Lissac, M.3    Morgon, L.4    Grosgogeat, B.5
  • 2
    • 0029685412 scopus 로고    scopus 로고
    • Corrosive properties of fluoride-containing odontologic gels against titanium
    • Toumelin-Chemla F., Rouelle F., and Burdairon G. Corrosive properties of fluoride-containing odontologic gels against titanium. J Dent 24 (1996) 109-115
    • (1996) J Dent , vol.24 , pp. 109-115
    • Toumelin-Chemla, F.1    Rouelle, F.2    Burdairon, G.3
  • 3
    • 0346977509 scopus 로고    scopus 로고
    • Sensitivity of titanium brackets to the corrosive influence of fluoride-containing toothpaste and tea
    • Harzer W., Schroter A., Gedrange T., and Muschter F. Sensitivity of titanium brackets to the corrosive influence of fluoride-containing toothpaste and tea. Angle Orthod 71 (2001) 318-323
    • (2001) Angle Orthod , vol.71 , pp. 318-323
    • Harzer, W.1    Schroter, A.2    Gedrange, T.3    Muschter, F.4
  • 4
    • 41849113722 scopus 로고
    • Einfluss von fluoridhaltigen zahnpasten auf zahnoberflächen (influence of fluoride-containing toothpastes on tooth surfaces)
    • Strietzel R. Einfluss von fluoridhaltigen zahnpasten auf zahnoberflächen (influence of fluoride-containing toothpastes on tooth surfaces). Zahnä Welt 103 (1994) 82-84
    • (1994) Zahnä Welt , vol.103 , pp. 82-84
    • Strietzel, R.1
  • 6
    • 0020162832 scopus 로고
    • Effect of long-term immersion corrosion on the flexural properties of nitinol
    • Schwaninger B., Sarkar N.K., and Foster B.E. Effect of long-term immersion corrosion on the flexural properties of nitinol. Am J Orthod 82 (1982) 45-49
    • (1982) Am J Orthod , vol.82 , pp. 45-49
    • Schwaninger, B.1    Sarkar, N.K.2    Foster, B.E.3
  • 7
    • 0033208653 scopus 로고    scopus 로고
    • An investigation into the effects on polishing on surface hardness and corrosion of orthodontic archwires
    • Hunt N.P., Cunningham S.J., Golden C.G., and Sheriff M. An investigation into the effects on polishing on surface hardness and corrosion of orthodontic archwires. Angle Orthod 69 (1999) 433-440
    • (1999) Angle Orthod , vol.69 , pp. 433-440
    • Hunt, N.P.1    Cunningham, S.J.2    Golden, C.G.3    Sheriff, M.4
  • 8
    • 0036595111 scopus 로고    scopus 로고
    • In vivo aging of orthodontic alloys: implications for corrosion potential, nickel release, and biocompatibility
    • Eliades T., and Athanasiou A.E. In vivo aging of orthodontic alloys: implications for corrosion potential, nickel release, and biocompatibility. Angle Orthod 72 (2002) 222-237
    • (2002) Angle Orthod , vol.72 , pp. 222-237
    • Eliades, T.1    Athanasiou, A.E.2
  • 9
    • 21644463979 scopus 로고    scopus 로고
    • Variation in corrosion resistance of nickel titanium wires from different manufacturers
    • Huang H. Variation in corrosion resistance of nickel titanium wires from different manufacturers. Angle Orthod 75 (2005) 661-665
    • (2005) Angle Orthod , vol.75 , pp. 661-665
    • Huang, H.1
  • 11
    • 0036263618 scopus 로고    scopus 로고
    • Corrosion susceptibility of lingual wire extensions in removable appliances. An in-vitro study
    • Fitjer L.C., Jonas I.E., and Kappert H.F. Corrosion susceptibility of lingual wire extensions in removable appliances. An in-vitro study. J Orofac Orthop 63 (2002) 212-226
    • (2002) J Orofac Orthop , vol.63 , pp. 212-226
    • Fitjer, L.C.1    Jonas, I.E.2    Kappert, H.F.3
  • 12
  • 13
    • 0026873596 scopus 로고
    • Composition and in vitro corrosion of orthodontic appliances
    • Grimsdottir M.R., Gjerdet N.R., and Hensten-Pettersen A. Composition and in vitro corrosion of orthodontic appliances. Am J Orthod 101 (1992) 525-532
    • (1992) Am J Orthod , vol.101 , pp. 525-532
    • Grimsdottir, M.R.1    Gjerdet, N.R.2    Hensten-Pettersen, A.3
  • 15
    • 0036617307 scopus 로고    scopus 로고
    • Cytotoxicity of orthodontic bands, brackets and archwires in vitro
    • Mockers O., Deroze D., and Camps J. Cytotoxicity of orthodontic bands, brackets and archwires in vitro. Dent Mater 18 (2002) 311-317
    • (2002) Dent Mater , vol.18 , pp. 311-317
    • Mockers, O.1    Deroze, D.2    Camps, J.3
  • 17
    • 0029171696 scopus 로고
    • Attachment corrosion and its testing
    • Matasa C.G. Attachment corrosion and its testing. J Clin Orthod 29 (1995) 16-23
    • (1995) J Clin Orthod , vol.29 , pp. 16-23
    • Matasa, C.G.1
  • 19
    • 0012801271 scopus 로고
    • Oral corrosion and corrosion inhibition processes
    • Palaghias G. Oral corrosion and corrosion inhibition processes. Swed Dent J 30 suppl (1985) 39-65
    • (1985) Swed Dent J , vol.30 , Issue.SUPPL , pp. 39-65
    • Palaghias, G.1
  • 20
    • 0026176470 scopus 로고
    • Corrosion of endodontic silver points in vivo
    • Margelos J., Eliades G., and Palaghias G. Corrosion of endodontic silver points in vivo. J Endod 17 (1991) 282-287
    • (1991) J Endod , vol.17 , pp. 282-287
    • Margelos, J.1    Eliades, G.2    Palaghias, G.3
  • 21
    • 77956982276 scopus 로고
    • The corrosion of orthodontic wire
    • Toms A.P. The corrosion of orthodontic wire. Eur J Orthod 10 (1988) 87-97
    • (1988) Eur J Orthod , vol.10 , pp. 87-97
    • Toms, A.P.1
  • 22
    • 41849147412 scopus 로고    scopus 로고
    • Elektrochemische charakterisierung unterschiedlicher verbindungen zwischen edelstahlkrone und klammerdraht (electrochemical characterization of different joinings between stainless steel crowns and clasps)
    • Müller W.D., Dorow S., Finke C.H., Petzold D., and Lange K.P. Elektrochemische charakterisierung unterschiedlicher verbindungen zwischen edelstahlkrone und klammerdraht (electrochemical characterization of different joinings between stainless steel crowns and clasps). Deut Zahnaerztl Z 59 (2004) 535-539
    • (2004) Deut Zahnaerztl Z , vol.59 , pp. 535-539
    • Müller, W.D.1    Dorow, S.2    Finke, C.H.3    Petzold, D.4    Lange, K.P.5
  • 23
    • 0033072152 scopus 로고    scopus 로고
    • Corrosion of stainless steel, nickel-titanium, coated nickel-titanium, and titanium orthodontic wires
    • Kim H., and Johnson J.W. Corrosion of stainless steel, nickel-titanium, coated nickel-titanium, and titanium orthodontic wires. Angle Orthod 69 (1999) 39-44
    • (1999) Angle Orthod , vol.69 , pp. 39-44
    • Kim, H.1    Johnson, J.W.2
  • 24
    • 0345888395 scopus 로고
    • Corrosion inhibition by salivary proteins and enzymes
    • Von Fraunhofer J.A. Corrosion inhibition by salivary proteins and enzymes. J Dent Res 71 (1992) 526
    • (1992) J Dent Res , vol.71 , pp. 526
    • Von Fraunhofer, J.A.1
  • 25
    • 41849118669 scopus 로고    scopus 로고
    • Hartung M, Fischer J, Grabowski R, Behrend D. Long term corrosion behaviour of TiN-coated brackets in vivo (abstract 252). Poster presented at the 75th Congress of the European Orthodontic Society; 23rd-26th June 1999; Strasbourg, Germany.
    • Hartung M, Fischer J, Grabowski R, Behrend D. Long term corrosion behaviour of TiN-coated brackets in vivo (abstract 252). Poster presented at the 75th Congress of the European Orthodontic Society; 23rd-26th June 1999; Strasbourg, Germany.
  • 26
    • 0022776331 scopus 로고
    • Biodegradation of the orthodontic bracket system
    • Maijer R., and Smith D.C. Biodegradation of the orthodontic bracket system. Am J Orthod 90 (1986) 195-198
    • (1986) Am J Orthod , vol.90 , pp. 195-198
    • Maijer, R.1    Smith, D.C.2
  • 27
    • 0019596946 scopus 로고
    • Fretting corrosion in saline and serum
    • Brown S., and Merritt K. Fretting corrosion in saline and serum. J Biomed Mater Res 15 (1981) 479-488
    • (1981) J Biomed Mater Res , vol.15 , pp. 479-488
    • Brown, S.1    Merritt, K.2
  • 28
    • 0034203508 scopus 로고    scopus 로고
    • Surface characterisation of retrieved NiTi orthodontic archwires
    • Eliades T., Eliades G., Athanasiou A.E., and Bradley T.G. Surface characterisation of retrieved NiTi orthodontic archwires. Eur J Orthod 22 (2000) 317-326
    • (2000) Eur J Orthod , vol.22 , pp. 317-326
    • Eliades, T.1    Eliades, G.2    Athanasiou, A.E.3    Bradley, T.G.4
  • 29
    • 0030628577 scopus 로고    scopus 로고
    • A review of contemporary archwires: their properties and characteristics
    • Kusy R.P. A review of contemporary archwires: their properties and characteristics. Angle Orthod 67 (1997) 197-207
    • (1997) Angle Orthod , vol.67 , pp. 197-207
    • Kusy, R.P.1
  • 30
    • 20444404207 scopus 로고    scopus 로고
    • Effect of fluoride prophylactic agents on the mechanical properties of nickel-titanium-based orthodontic wires
    • Walker M.P., White R.J., and Kula K.S. Effect of fluoride prophylactic agents on the mechanical properties of nickel-titanium-based orthodontic wires. Am J Orthod Dentofacial Orthop 127 (2005) 662-669
    • (2005) Am J Orthod Dentofacial Orthop , vol.127 , pp. 662-669
    • Walker, M.P.1    White, R.J.2    Kula, K.S.3
  • 31
    • 0035882635 scopus 로고    scopus 로고
    • Degradation and fracture of Ni-Ti superelastic wire in an oral cavity
    • Yokoyama K., Hamada K., Moriyama K., and Asaoka K. Degradation and fracture of Ni-Ti superelastic wire in an oral cavity. Biomaterials 22 (2001) 2257-2262
    • (2001) Biomaterials , vol.22 , pp. 2257-2262
    • Yokoyama, K.1    Hamada, K.2    Moriyama, K.3    Asaoka, K.4
  • 33
    • 0035651498 scopus 로고    scopus 로고
    • Effects of recycling on the mechanical properties and the surface topography of nickel-titanium alloy wires
    • Lee S.H., and Chang Y. Effects of recycling on the mechanical properties and the surface topography of nickel-titanium alloy wires. Am J Orthod Dentofacial Orthop 120 (2001) 654-663
    • (2001) Am J Orthod Dentofacial Orthop , vol.120 , pp. 654-663
    • Lee, S.H.1    Chang, Y.2
  • 34
    • 0023970975 scopus 로고
    • Effects of sterilization on the mechanical properties and the surface topography of nickel-titanium arch wires
    • Mayhew M.J., and Kusy R.P. Effects of sterilization on the mechanical properties and the surface topography of nickel-titanium arch wires. Am J Orthod Dentofacial Orthop 93 (1988) 232-236
    • (1988) Am J Orthod Dentofacial Orthop , vol.93 , pp. 232-236
    • Mayhew, M.J.1    Kusy, R.P.2
  • 35
    • 18044399863 scopus 로고    scopus 로고
    • California proposition may help patients in search of better oral health
    • Turpin D.L. California proposition may help patients in search of better oral health. Am J Orthod Dentofacial Orthop 120 (2001) 97-99
    • (2001) Am J Orthod Dentofacial Orthop , vol.120 , pp. 97-99
    • Turpin, D.L.1
  • 36
    • 0033627654 scopus 로고    scopus 로고
    • Assessment of acute cyto- and genotoxicity of corrosion eluates obtained from orthodontic materials using monolayer cultures of immortalized human gingival keratinocytes
    • Tomakidi P., Koke U., Kern R., Erdinger L., Krüger H., Kohl A., et al. Assessment of acute cyto- and genotoxicity of corrosion eluates obtained from orthodontic materials using monolayer cultures of immortalized human gingival keratinocytes. J Orofac Orthop 61 (2000) 2-19
    • (2000) J Orofac Orthop , vol.61 , pp. 2-19
    • Tomakidi, P.1    Koke, U.2    Kern, R.3    Erdinger, L.4    Krüger, H.5    Kohl, A.6
  • 37
    • 0024654174 scopus 로고
    • Allergic reaction to orthodontic wire: report of case
    • Dunlap C.L., Vincent S.K., and Barker B.F. Allergic reaction to orthodontic wire: report of case. J Am Dent Assoc 118 (1989) 449-450
    • (1989) J Am Dent Assoc , vol.118 , pp. 449-450
    • Dunlap, C.L.1    Vincent, S.K.2    Barker, B.F.3
  • 38
    • 0030623657 scopus 로고    scopus 로고
    • Orthodontic appliances in relation to nickel hypersensitivity: a review
    • Lindsten R., and Kurol J. Orthodontic appliances in relation to nickel hypersensitivity: a review. J Orofac Orthop 58 (1997) 100-108
    • (1997) J Orofac Orthop , vol.58 , pp. 100-108
    • Lindsten, R.1    Kurol, J.2
  • 39
    • 0025181043 scopus 로고
    • Nickel allergy and orthodontic treatment
    • Starkjaer L., and Menne T. Nickel allergy and orthodontic treatment. Eur J Orthod 12 (1990) 284-289
    • (1990) Eur J Orthod , vol.12 , pp. 284-289
    • Starkjaer, L.1    Menne, T.2
  • 40
    • 0026920421 scopus 로고
    • Casting alloys: side effects
    • Hensten-Petersen A. Casting alloys: side effects. Adv Dent Res 6 (1992) 38-43
    • (1992) Adv Dent Res , vol.6 , pp. 38-43
    • Hensten-Petersen, A.1
  • 41
    • 0021110612 scopus 로고
    • Contact dermatitis reaction to a metal buckle on a cervical headgear
    • Greig D.G.M. Contact dermatitis reaction to a metal buckle on a cervical headgear. Br Dent J 155 (1983) 61-62
    • (1983) Br Dent J , vol.155 , pp. 61-62
    • Greig, D.G.M.1
  • 42
    • 0027342981 scopus 로고
    • Biodegradation of orthodontic appliances. Part I. Biodegradation of nickel and chromium in vitro
    • Barrett R.D., Bishara S.E., and Quinn J.K. Biodegradation of orthodontic appliances. Part I. Biodegradation of nickel and chromium in vitro. Am J Orthod Dentofacial Orthop 103 (1993) 8-14
    • (1993) Am J Orthod Dentofacial Orthop , vol.103 , pp. 8-14
    • Barrett, R.D.1    Bishara, S.E.2    Quinn, J.K.3
  • 43
    • 0020808537 scopus 로고
    • In vitro release of nickel and chromium from simulated orthodontic appliances
    • Park H.Y., and Shearer T.R. In vitro release of nickel and chromium from simulated orthodontic appliances. Am J Orthod 84 (1983) 156-159
    • (1983) Am J Orthod , vol.84 , pp. 156-159
    • Park, H.Y.1    Shearer, T.R.2
  • 44
    • 0022973779 scopus 로고
    • Metal release from dental biomaterials
    • Brune D. Metal release from dental biomaterials. Biomaterials 7 (1986) 163-175
    • (1986) Biomaterials , vol.7 , pp. 163-175
    • Brune, D.1
  • 45
    • 3042585380 scopus 로고    scopus 로고
    • Nickel content of as-received and retrieved NiTi and stainless steel archwires: assessing the nickel release hypothesis
    • Eliades T., Zinelis S., Papadopoulos M.A., Eliades G., and Athanasiou A.E. Nickel content of as-received and retrieved NiTi and stainless steel archwires: assessing the nickel release hypothesis. Angle Orthod 74 (2004) 151-154
    • (2004) Angle Orthod , vol.74 , pp. 151-154
    • Eliades, T.1    Zinelis, S.2    Papadopoulos, M.A.3    Eliades, G.4    Athanasiou, A.E.5
  • 46
    • 0035404376 scopus 로고    scopus 로고
    • Comparison of ion release from new and recycled orthodontic brackets
    • Huang T., Yen C., and Kao C. Comparison of ion release from new and recycled orthodontic brackets. Am J Orthod Dentofacial Orthop 120 (2001) 68-75
    • (2001) Am J Orthod Dentofacial Orthop , vol.120 , pp. 68-75
    • Huang, T.1    Yen, C.2    Kao, C.3
  • 47
    • 0031159371 scopus 로고    scopus 로고
    • Salivary nickel and chromium in subjects with different types of fixed orthodontic appliances
    • Kerosuo H., Moe G., and Hensten-Pettersen A. Salivary nickel and chromium in subjects with different types of fixed orthodontic appliances. Am J Orthod Dentofacial Orthop 111 (1997) 595-598
    • (1997) Am J Orthod Dentofacial Orthop , vol.111 , pp. 595-598
    • Kerosuo, H.1    Moe, G.2    Hensten-Pettersen, A.3
  • 48
    • 0029183960 scopus 로고
    • In vitro release of nickel and chromium from different types of simulated orthodontic appliances
    • Kerosuo H., Moe G., and Kleven E. In vitro release of nickel and chromium from different types of simulated orthodontic appliances. Angle Orthod 65 (1995) 111-116
    • (1995) Angle Orthod , vol.65 , pp. 111-116
    • Kerosuo, H.1    Moe, G.2    Kleven, E.3
  • 49
    • 0035486973 scopus 로고    scopus 로고
    • Nickel and chromium levels in the saliva and serum of patients with fixed orthodontic appliances
    • Agaoglu G., Arun T., Izgu B., and Yarat A. Nickel and chromium levels in the saliva and serum of patients with fixed orthodontic appliances. Angle Orthod 71 (2001) 375-379
    • (2001) Angle Orthod , vol.71 , pp. 375-379
    • Agaoglu, G.1    Arun, T.2    Izgu, B.3    Yarat, A.4
  • 50
    • 84989573863 scopus 로고
    • Cytotoxic and antibacterial effects of orthodontic appliances
    • Grimsdottir M.R., and Hensten-Pettersen A. Cytotoxic and antibacterial effects of orthodontic appliances. Scand J Dent Res 101 (1993) 229-231
    • (1993) Scand J Dent Res , vol.101 , pp. 229-231
    • Grimsdottir, M.R.1    Hensten-Pettersen, A.2
  • 51
    • 84988992491 scopus 로고
    • Nickel hypersensitivity reactions in orthodontic patients
    • Greppi L., Smith D.C., and Woodside D.G. Nickel hypersensitivity reactions in orthodontic patients. J Dent Res 70 (1991) 361
    • (1991) J Dent Res , vol.70 , pp. 361
    • Greppi, L.1    Smith, D.C.2    Woodside, D.G.3
  • 52
    • 2642582913 scopus 로고    scopus 로고
    • Biocompatility of nickel titanium shape memory metal and its corrosion behaviour in human cell cultures
    • Ryhanen J., Niemi E., Serlo W., Niemela E., Sandvik P., Pernu H., et al. Biocompatility of nickel titanium shape memory metal and its corrosion behaviour in human cell cultures. J Biomed Mater Res 35 (1996) 451-457
    • (1996) J Biomed Mater Res , vol.35 , pp. 451-457
    • Ryhanen, J.1    Niemi, E.2    Serlo, W.3    Niemela, E.4    Sandvik, P.5    Pernu, H.6
  • 54
    • 0027570091 scopus 로고
    • Nickel hypersensitivity in the orthodontic patient
    • Bass J.K. Nickel hypersensitivity in the orthodontic patient. Am J Orthod 103 (1993) 280-285
    • (1993) Am J Orthod , vol.103 , pp. 280-285
    • Bass, J.K.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.