메뉴 건너뛰기




Volumn 75, Issue 4, 2005, Pages 661-665

Variation in corrosion resistance of Nickel-titanium wires from different manufacturers

Author keywords

Corrosion resistance; NiTi; Orthodontic wire; Polarization resistance; Roughness

Indexed keywords

NICKEL; SALIVA SUBSTITUTE; TITANIUM;

EID: 21644463979     PISSN: 00033219     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (47)

References (23)
  • 1
    • 0038384453 scopus 로고    scopus 로고
    • Ion release from NiTi orthodontic wires in artificial saliva with various acidities
    • Huang HH, Chiu YH, Lee TH, Wu SC, Yang HY, Su KH, Hsu CC. Ion release from NiTi orthodontic wires in artificial saliva with various acidities. Biomaterials. 2003;24:3585-3592.
    • (2003) Biomaterials , vol.24 , pp. 3585-3592
    • Huang, H.H.1    Chiu, Y.H.2    Lee, T.H.3    Wu, S.C.4    Yang, H.Y.5    Su, K.H.6    Hsu, C.C.7
  • 2
    • 0026515161 scopus 로고
    • Reaction to stainless steel wire following orthognathic surgery
    • Guyuron B, Lasa CI Jr. Reaction to stainless steel wire following orthognathic surgery. Plast Reconstr Surg. 1992;89:540-542.
    • (1992) Plast Reconstr Surg , vol.89 , pp. 540-542
    • Guyuron, B.1    Lasa Jr., C.I.2
  • 4
    • 2642582913 scopus 로고    scopus 로고
    • Biocompatibility of nickel-titanium shape memory metal and its corrosion behavior in human cell cultures
    • Ryhanen J, Niemi E, Serlo W, Niemela E, Sandvik P, Pernu H, Salo T. Biocompatibility of nickel-titanium shape memory metal and its corrosion behavior in human cell cultures. J Biomed Mater Res. 1997;35:451-457.
    • (1997) J Biomed Mater Res , vol.35 , pp. 451-457
    • Ryhanen, J.1    Niemi, E.2    Serlo, W.3    Niemela, E.4    Sandvik, P.5    Pernu, H.6    Salo, T.7
  • 6
    • 0034038826 scopus 로고    scopus 로고
    • Evaluation by electrochemical tests of the passive film stability of equiatomic NiTi alloy also in presence of stress-induced martensite
    • Rondelli G, Vicentini B. Evaluation by electrochemical tests of the passive film stability of equiatomic NiTi alloy also in presence of stress-induced martensite. J Biomed Mater Res. 2000;51:47-54.
    • (2000) J Biomed Mater Res , vol.51 , pp. 47-54
    • Rondelli, G.1    Vicentini, B.2
  • 7
    • 0346124163 scopus 로고    scopus 로고
    • Corrosion resistance of stressed NiTi and stainless steel orthodontic wires in acid artificial saliva
    • Huang HH. Corrosion resistance of stressed NiTi and stainless steel orthodontic wires in acid artificial saliva. J Biomed Mater Res. 2003;66A:829-839.
    • (2003) J Biomed Mater Res , vol.66 A , pp. 829-839
    • Huang, H.H.1
  • 8
    • 0041804110 scopus 로고    scopus 로고
    • In vitro surface corrosion of stainless steel and NiTi orthodontic appliances
    • Shin JS, Oh KT, Hwang CJ. In vitro surface corrosion of stainless steel and NiTi orthodontic appliances. Aust Orthod J. 2003;19:13-18.
    • (2003) Aust Orthod J , vol.19 , pp. 13-18
    • Shin, J.S.1    Oh, K.T.2    Hwang, C.J.3
  • 9
    • 0033072152 scopus 로고    scopus 로고
    • Corrosion of stainless steel, nickel-titanium, coated nickel-titanium, and titanium orthodontic wires
    • Kim H, Johnson JW. Corrosion of stainless steel, nickel-titanium, coated nickel-titanium, and titanium orthodontic wires. Angle Orthod. 1999;69:39-44.
    • (1999) Angle Orthod , vol.69 , pp. 39-44
    • Kim, H.1    Johnson, J.W.2
  • 10
    • 0033208653 scopus 로고    scopus 로고
    • An investigation into the effects of polishing on surface hardness and corrosion of orthodontic archwires
    • Hunt NP, Cunningham SJ, Golden CG, Sheriff M. An investigation into the effects of polishing on surface hardness and corrosion of orthodontic archwires. Angle Orthod. 1999;69:433-440.
    • (1999) Angle Orthod , vol.69 , pp. 433-440
    • Hunt, N.P.1    Cunningham, S.J.2    Golden, C.G.3    Sheriff, M.4
  • 11
    • 0022017053 scopus 로고
    • Effect of potassium thiocyanate on corrosion behavior of non-precious metal dental alloys
    • Geis-Gerstorfer J, Weber H. Effect of potassium thiocyanate on corrosion behavior of non-precious metal dental alloys. Dtsch Zahnärztl Z. 1985;40:87-91.
    • (1985) Dtsch Zahnärztl Z , vol.40 , pp. 87-91
    • Geis-Gerstorfer, J.1    Weber, H.2
  • 12
    • 0001054275 scopus 로고
    • Influence of artificial salivas on the corrosion of dental alloys
    • Mayer JM, Nally JN. Influence of artificial salivas on the corrosion of dental alloys. J Dent Res. 1975;54:678.
    • (1975) J Dent Res , vol.54 , pp. 678
    • Mayer, J.M.1    Nally, J.N.2
  • 15
    • 0033119606 scopus 로고    scopus 로고
    • Localized corrosion behavior in simulated human body fluids of commercial Ni-Ti orthodontic wires
    • Rondelli G, Vicentini B. Localized corrosion behavior in simulated human body fluids of commercial Ni-Ti orthodontic wires. Biomaterials. 1999;20:785-792.
    • (1999) Biomaterials , vol.20 , pp. 785-792
    • Rondelli, G.1    Vicentini, B.2
  • 16
    • 0034666762 scopus 로고    scopus 로고
    • Effect of surface treatment and sterilization processes on the corrosion behavior of NiTi shape memory alloy
    • Thierry B, Tabrizian M, Trepanier C, Savadogo O, Yahia L'H. Effect of surface treatment and sterilization processes on the corrosion behavior of NiTi shape memory alloy. J Biomed Mater Res. 2000;51:685-693.
    • (2000) J Biomed Mater Res , vol.51 , pp. 685-693
    • Thierry, B.1    Tabrizian, M.2    Trepanier, C.3    Savadogo, O.4    Yahia, L'H.5
  • 18
    • 0026879344 scopus 로고
    • Microanalytical characterization and surface modification of TiNi orthodontic archwires
    • Oshida Y, Sachdeva RCL, Miyazaki S. Microanalytical characterization and surface modification of TiNi orthodontic archwires. Biomed Mater Eng. 1992;2:51-69.
    • (1992) Biomed Mater Eng , vol.2 , pp. 51-69
    • Oshida, Y.1    Sachdeva, R.C.L.2    Miyazaki, S.3
  • 19
    • 84956040351 scopus 로고
    • Surface spectroscopy characterization of NiTi nearly equiatomic shape memory alloy for implants
    • Shabalovskaya SA, Anderegg JM. Surface spectroscopy characterization of NiTi nearly equiatomic shape memory alloy for implants. J Vac Sci Technol A. 1995;13:2624-2632.
    • (1995) J Vac Sci Technol A , vol.13 , pp. 2624-2632
    • Shabalovskaya, S.A.1    Anderegg, J.M.2
  • 20
    • 0000359641 scopus 로고
    • Corrosion and biocompatibility of shape memory alloys
    • Oshida Y, Miyazaki S. Corrosion and biocompatibility of shape memory alloys. Corros Eng. 1991;40:1009-1025.
    • (1991) Corros Eng , vol.40 , pp. 1009-1025
    • Oshida, Y.1    Miyazaki, S.2
  • 21
    • 0024709613 scopus 로고
    • In vivo measurement of anodic polarization of orthopaedic implant alloys: Comparative study of in vivo and in vitro experiments
    • Nakayama Y, Yamamuro T, Kotoura Y, Oka M. In vivo measurement of anodic polarization of orthopaedic implant alloys: comparative study of in vivo and in vitro experiments. Biomaterials. 1989;10:420-424.
    • (1989) Biomaterials , vol.10 , pp. 420-424
    • Nakayama, Y.1    Yamamuro, T.2    Kotoura, Y.3    Oka, M.4
  • 23
    • 0037209975 scopus 로고    scopus 로고
    • Effect of fluoride and albumin concentration on the corrosion behavior of Ti-6Al-4V alloy
    • Huang HH. Effect of fluoride and albumin concentration on the corrosion behavior of Ti-6Al-4V alloy. Biomaterials. 2003;24:275-282.
    • (2003) Biomaterials , vol.24 , pp. 275-282
    • Huang, H.H.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.