메뉴 건너뛰기




Volumn 64, Issue SUPPL. 4, 2008, Pages

Closed-loop strategies for patient care systems

Author keywords

Closed loop; Critical care medicine; Mass casualty

Indexed keywords

ARTIFICIAL VENTILATION; CLOSED LOOP CONTROL TECHNIQUE; FEEDBACK SYSTEM; HEALTH CARE DELIVERY; HEALTH CARE QUALITY; INTENSIVE CARE UNIT; PATIENT CARE; PRACTICE GUIDELINE; PRIORITY JOURNAL; RESUSCITATION; REVIEW; TRAUMATIC BRAIN INJURY;

EID: 41849091829     PISSN: 00225282     EISSN: 15298809     Source Type: Journal    
DOI: 10.1097/TA.0b013e31816bce43     Document Type: Review
Times cited : (23)

References (58)
  • 2
    • 0028240223 scopus 로고
    • Quantitation of the interaction of rocuronium bromide with etomidate, fentanyl, midazolam, propofol, thiopentone, and isoflurane using closed-loop feedback control of infusion of rocuronium
    • Olkkola KT, Tammisto T. Quantitation of the interaction of rocuronium bromide with etomidate, fentanyl, midazolam, propofol, thiopentone, and isoflurane using closed-loop feedback control of infusion of rocuronium. Eur J Anaesthesiol Suppl. 1994;9:99-100.
    • (1994) Eur J Anaesthesiol Suppl , vol.9 , pp. 99-100
    • Olkkola, K.T.1    Tammisto, T.2
  • 3
    • 0032807943 scopus 로고    scopus 로고
    • Closed-loop control of propofol anaesthesia
    • Kenny GN, Mantzaridis H. Closed-loop control of propofol anaesthesia. Br J Anaesth. 1999;83:223-228.
    • (1999) Br J Anaesth , vol.83 , pp. 223-228
    • Kenny, G.N.1    Mantzaridis, H.2
  • 4
    • 0035726987 scopus 로고    scopus 로고
    • Knowledge-based systems for automatic ventilatory management
    • viii
    • Dojat M, Brochard L. Knowledge-based systems for automatic ventilatory management. Respir Care Clin N Am. 2001;7:379-396, viii.
    • (2001) Respir Care Clin N Am , vol.7 , pp. 379-396
    • Dojat, M.1    Brochard, L.2
  • 5
    • 1842277916 scopus 로고
    • Physiologically oriented artificial respirator which produces N2O-O2 anesthesia in man
    • Frumin JM, Lee ASJ. Physiologically oriented artificial respirator which produces N2O-O2 anesthesia in man. J Lab Clin Med. 1958;49:617-629.
    • (1958) J Lab Clin Med , vol.49 , pp. 617-629
    • Frumin, J.M.1    Lee, A.S.J.2
  • 8
    • 2642515683 scopus 로고    scopus 로고
    • Servo-controlled pneumatic pressure oscillator for respiratory impedance measurements and high-frequency ventilation
    • Kaczka DW, Lutchen KR. Servo-controlled pneumatic pressure oscillator for respiratory impedance measurements and high-frequency ventilation. Ann Biomed Eng. 2004;32:596-608.
    • (2004) Ann Biomed Eng , vol.32 , pp. 596-608
    • Kaczka, D.W.1    Lutchen, K.R.2
  • 11
    • 0036134523 scopus 로고    scopus 로고
    • The effects of motion artifact and low perfusion on the performance of a new generation of pulse oximeters in volunteers undergoing hypoxemia
    • Gehring H, Hornberger C, Matz H, Konecny E, Schmucker P. The effects of motion artifact and low perfusion on the performance of a new generation of pulse oximeters in volunteers undergoing hypoxemia. Respir Care. 2002;47:48-60.
    • (2002) Respir Care , vol.47 , pp. 48-60
    • Gehring, H.1    Hornberger, C.2    Matz, H.3    Konecny, E.4    Schmucker, P.5
  • 12
    • 0016842725 scopus 로고
    • Decision tables. Their use for the presentation of clinical algorithms
    • Holland RR. Decision tables. Their use for the presentation of clinical algorithms. JAMA. 1975;233:455-457.
    • (1975) JAMA , vol.233 , pp. 455-457
    • Holland, R.R.1
  • 13
    • 0036040043 scopus 로고    scopus 로고
    • A closed-loop controller for mechanical ventilation of patients with ARDS
    • Anderson JR, East TD. A closed-loop controller for mechanical ventilation of patients with ARDS. Biomed Sci Instrum. 2002;38:289-294.
    • (2002) Biomed Sci Instrum , vol.38 , pp. 289-294
    • Anderson, J.R.1    East, T.D.2
  • 14
    • 0031226273 scopus 로고    scopus 로고
    • Representation of clinical practice guidelines in conventional and augmented decision tables
    • Shiffman RN. Representation of clinical practice guidelines in conventional and augmented decision tables. J Am Med Inform Assoc. 1997;4:382-393.
    • (1997) J Am Med Inform Assoc , vol.4 , pp. 382-393
    • Shiffman, R.N.1
  • 15
    • 41849138738 scopus 로고    scopus 로고
    • Dumont GA, Huzmezan M. Concepts, Methods and Techniques in Adaptive Control. Canada: Department of Electrical and Computer Engineering, University of British Columbia B.C.; 2002.
    • Dumont GA, Huzmezan M. Concepts, Methods and Techniques in Adaptive Control. Canada: Department of Electrical and Computer Engineering, University of British Columbia B.C.; 2002.
  • 17
    • 33745675207 scopus 로고    scopus 로고
    • Closed-loop resuscitation of burn shock
    • Hoskins SL, Elgjo GI, Lu J, et al. Closed-loop resuscitation of burn shock. J Burn Care Res. 2006;27:377-385.
    • (2006) J Burn Care Res , vol.27 , pp. 377-385
    • Hoskins, S.L.1    Elgjo, G.I.2    Lu, J.3
  • 20
    • 4644308594 scopus 로고    scopus 로고
    • Mechanical ventilation in orbit: Emphasis on closed-loop ventilation
    • vii
    • Kaczka DW, Beck G. Mechanical ventilation in orbit: emphasis on closed-loop ventilation. Respir Care Clin N Am. 2004;10:369-400, vii.
    • (2004) Respir Care Clin N Am , vol.10 , pp. 369-400
    • Kaczka, D.W.1    Beck, G.2
  • 21
    • 1642303038 scopus 로고    scopus 로고
    • Long-term effects of different humidification systems on endotracheal tube patency: Evaluation by the acoustic reflection method
    • Jaber S, Pigeot J, Fodil R, et al. Long-term effects of different humidification systems on endotracheal tube patency: evaluation by the acoustic reflection method. Anesthesiology. 2004;100:782-788.
    • (2004) Anesthesiology , vol.100 , pp. 782-788
    • Jaber, S.1    Pigeot, J.2    Fodil, R.3
  • 22
    • 0029817243 scopus 로고    scopus 로고
    • The effect of a heat and moisture exchanger (HME) on bronchial mucus transport in a closed inhalation anesthesia system
    • Konrad F, Mezody M, Goertz A, Marx T, Georgieff M. The effect of a heat and moisture exchanger (HME) on bronchial mucus transport in a closed inhalation anesthesia system. Anaesthesist. 1996;45:802-806.
    • (1996) Anaesthesist , vol.45 , pp. 802-806
    • Konrad, F.1    Mezody, M.2    Goertz, A.3    Marx, T.4    Georgieff, M.5
  • 23
    • 1942421711 scopus 로고    scopus 로고
    • Controlling bleeding in the field: Hemostatic powders and dressings debut in the prehospital setting
    • Robinson K. Controlling bleeding in the field: hemostatic powders and dressings debut in the prehospital setting. J Emerg Nurs. 2004;30:160-161.
    • (2004) J Emerg Nurs , vol.30 , pp. 160-161
    • Robinson, K.1
  • 24
    • 0036785830 scopus 로고    scopus 로고
    • Motion-resistant pulse oximetry: A comparison of new and old models
    • table of contents
    • Barker SJ. "Motion-resistant" pulse oximetry: a comparison of new and old models. Anesth Analg. 2002;95:967-972, table of contents.
    • (2002) Anesth Analg , vol.95 , pp. 967-972
    • Barker, S.J.1
  • 25
    • 0031978712 scopus 로고    scopus 로고
    • Laryngeal mask airway position and the risk of gastric insufflation
    • Latorre F, Eberle B, Weiler N, et al. Laryngeal mask airway position and the risk of gastric insufflation. Anesth Analg. 1998;86:867-871.
    • (1998) Anesth Analg , vol.86 , pp. 867-871
    • Latorre, F.1    Eberle, B.2    Weiler, N.3
  • 26
    • 7044272468 scopus 로고    scopus 로고
    • A concept of operations for contingency medical care on the international space station
    • Bacal K, Beck G, McSwain NE Jr. A concept of operations for contingency medical care on the international space station. Mil Med. 2004;169:631-641.
    • (2004) Mil Med , vol.169 , pp. 631-641
    • Bacal, K.1    Beck, G.2    McSwain Jr, N.E.3
  • 27
    • 0031459390 scopus 로고    scopus 로고
    • Computer-controlled minute ventilation in preterm infants undergoing mechanical ventilation
    • Claure N, Gerhardt T, Hummler H, Everett R, Bancalari E. Computer-controlled minute ventilation in preterm infants undergoing mechanical ventilation. J Pediatr. 1997;131:910-913.
    • (1997) J Pediatr , vol.131 , pp. 910-913
    • Claure, N.1    Gerhardt, T.2    Hummler, H.3    Everett, R.4    Bancalari, E.5
  • 28
    • 7444234860 scopus 로고    scopus 로고
    • Recent advances in intravenous anaesthesia
    • Sneyd JR. Recent advances in intravenous anaesthesia. Br J Anaesth. 2004;93:725-736.
    • (2004) Br J Anaesth , vol.93 , pp. 725-736
    • Sneyd, J.R.1
  • 30
    • 0242269054 scopus 로고    scopus 로고
    • Target-controlled infusions for intravenous anesthetics: Surfing USA not!
    • Egan TD, Shafer SL. Target-controlled infusions for intravenous anesthetics: Surfing USA not! Anesthesiology. 2003;99:1039-1041.
    • (2003) Anesthesiology , vol.99 , pp. 1039-1041
    • Egan, T.D.1    Shafer, S.L.2
  • 31
    • 0034895041 scopus 로고    scopus 로고
    • Propofol dosing regimens for ICU sedation based upon an integrated pharmacokinetic-pharmacodynamic model
    • Barr J, Egan TD, Sandoval NF, et al. Propofol dosing regimens for ICU sedation based upon an integrated pharmacokinetic-pharmacodynamic model. Anesthesiology. 2001;95:324-333.
    • (2001) Anesthesiology , vol.95 , pp. 324-333
    • Barr, J.1    Egan, T.D.2    Sandoval, N.F.3
  • 32
    • 0031862192 scopus 로고    scopus 로고
    • Future applications for TCI systems
    • Milne SE, Kenny GN. Future applications for TCI systems. Anaesthesia. 1998;53(Suppl 1):56-60.
    • (1998) Anaesthesia , vol.53 , Issue.SUPPL. 1 , pp. 56-60
    • Milne, S.E.1    Kenny, G.N.2
  • 33
    • 0037526501 scopus 로고    scopus 로고
    • Closed-loop control of propofol anaesthesia using bispectral index: Performance assessment in patients receiving computer-controlled propofol and manually controlled remifentanil infusions for minor surgery
    • Absalom AR, Kenny GN. Closed-loop control of propofol anaesthesia using bispectral index: performance assessment in patients receiving computer-controlled propofol and manually controlled remifentanil infusions for minor surgery. Br J Anaesth. 2003;90:737-741.
    • (2003) Br J Anaesth , vol.90 , pp. 737-741
    • Absalom, A.R.1    Kenny, G.N.2
  • 34
    • 33645637189 scopus 로고    scopus 로고
    • Feasibility of closed-loop titration of propofol guided by the bispectral index for general anaesthesia induction: A prospective randomized study
    • Liu N, Chazot T, Trillat B, et al. Feasibility of closed-loop titration of propofol guided by the bispectral index for general anaesthesia induction: a prospective randomized study. Eur J Anaesthesiol. 2006;23:465-469.
    • (2006) Eur J Anaesthesiol , vol.23 , pp. 465-469
    • Liu, N.1    Chazot, T.2    Trillat, B.3
  • 35
    • 1442308365 scopus 로고    scopus 로고
    • Performance evaluation of two published closed-loop control systems using bispectral index monitoring: A simulation study
    • Struys MM, De Smet T, Greenwald S, Absalom AR, Binge S, Mortier EP. Performance evaluation of two published closed-loop control systems using bispectral index monitoring: a simulation study. Anesthesiology. 2004;100:640-647.
    • (2004) Anesthesiology , vol.100 , pp. 640-647
    • Struys, M.M.1    De Smet, T.2    Greenwald, S.3    Absalom, A.R.4    Binge, S.5    Mortier, E.P.6
  • 36
    • 0034934646 scopus 로고    scopus 로고
    • Automated anesthesia: Fact or fantasy?
    • Glass PS, Rampil IJ. Automated anesthesia: fact or fantasy? Anesthesiology. 2001;95:1-2.
    • (2001) Anesthesiology , vol.95 , pp. 1-2
    • Glass, P.S.1    Rampil, I.J.2
  • 38
    • 0036309803 scopus 로고    scopus 로고
    • How reliable is the bispectral index in critically ill patients? A prospective, comparative, single-blinded observer study
    • Nasraway SA Jr, Wu EC, Kelleher RM, Yasuda CM, Donnelly AM. How reliable is the bispectral index in critically ill patients? A prospective, comparative, single-blinded observer study. Crit Care Med. 2002;30:1483-1487.
    • (2002) Crit Care Med , vol.30 , pp. 1483-1487
    • Nasraway Jr, S.A.1    Wu, E.C.2    Kelleher, R.M.3    Yasuda, C.M.4    Donnelly, A.M.5
  • 41
    • 0038450015 scopus 로고    scopus 로고
    • Overestimation of bispectral index in sedated intensive care unit patients revealed by administration of muscle relaxant
    • Vivien B, Di Maria S, Ouattara A, Langeron O, Coriat P, Riou B. Overestimation of bispectral index in sedated intensive care unit patients revealed by administration of muscle relaxant. Anesthesiology. 2003;99:9-17.
    • (2003) Anesthesiology , vol.99 , pp. 9-17
    • Vivien, B.1    Di Maria, S.2    Ouattara, A.3    Langeron, O.4    Coriat, P.5    Riou, B.6
  • 42
    • 0027131721 scopus 로고
    • A versatile, computer-controlled, closed-loop system for continuous infusion of muscle relaxants
    • Assef SJ, Lennon RL, Jones KA, Burke MJ, Behrens TL. A versatile, computer-controlled, closed-loop system for continuous infusion of muscle relaxants. Mayo Clin Proc. 1993;68:1074-1080.
    • (1993) Mayo Clin Proc , vol.68 , pp. 1074-1080
    • Assef, S.J.1    Lennon, R.L.2    Jones, K.A.3    Burke, M.J.4    Behrens, T.L.5
  • 43
    • 0036894793 scopus 로고    scopus 로고
    • Prolonged closed-loop control of muscle relaxation using rocuronium
    • De Haes A, Eleveld DJ, Wierda JM. Prolonged closed-loop control of muscle relaxation using rocuronium. Anaesthesia. 2002;57:1237-1238.
    • (2002) Anaesthesia , vol.57 , pp. 1237-1238
    • De Haes, A.1    Eleveld, D.J.2    Wierda, J.M.3
  • 44
    • 23944481905 scopus 로고    scopus 로고
    • Evaluation of a closed-loop muscle relaxation control system
    • table of contents
    • Eleveld DJ, Proost JH, Wierda JM. Evaluation of a closed-loop muscle relaxation control system. Anesth Analg. 2005;101:758-764, table of contents.
    • (2005) Anesth Analg , vol.101 , pp. 758-764
    • Eleveld, D.J.1    Proost, J.H.2    Wierda, J.M.3
  • 45
    • 0031239474 scopus 로고    scopus 로고
    • Fuzzy logic for model adaptation of a pharmacokinetic-based closed loop delivery system for pancuronium
    • Kern SE, Johnson JO, Westenskow DR. Fuzzy logic for model adaptation of a pharmacokinetic-based closed loop delivery system for pancuronium. Artif Intell Med. 1997;11:9-31.
    • (1997) Artif Intell Med , vol.11 , pp. 9-31
    • Kern, S.E.1    Johnson, J.O.2    Westenskow, D.R.3
  • 46
    • 0027516906 scopus 로고
    • Closed loop control of arterial hypertension following intracranial surgery using sodium nitroprusside. A comparison of intra-operative halothane or isoflurane
    • Mackenzie AF, Colvin JR, Kenny GN, Bisset WI. Closed loop control of arterial hypertension following intracranial surgery using sodium nitroprusside. A comparison of intra-operative halothane or isoflurane. Anaesthesia. 1993;48:202-204.
    • (1993) Anaesthesia , vol.48 , pp. 202-204
    • Mackenzie, A.F.1    Colvin, J.R.2    Kenny, G.N.3    Bisset, W.I.4
  • 48
    • 0022388189 scopus 로고
    • Management of postcardiotomy hypertension by microcomputer-controlled administration of sodium nitroprusside
    • de Asla RA, Benis AM, Jurado RA, Litwak RS. Management of postcardiotomy hypertension by microcomputer-controlled administration of sodium nitroprusside. J Thorac Cardiovasc Surg. 1985;89:115-120.
    • (1985) J Thorac Cardiovasc Surg , vol.89 , pp. 115-120
    • de Asla, R.A.1    Benis, A.M.2    Jurado, R.A.3    Litwak, R.S.4
  • 49
    • 17844409621 scopus 로고    scopus 로고
    • Targeted glycemic reduction in critical care using closed-loop control
    • Chase JG, Shaw GM, Lin J, et al. Targeted glycemic reduction in critical care using closed-loop control. Diabetes Technol Ther. 2005;7:274-282.
    • (2005) Diabetes Technol Ther , vol.7 , pp. 274-282
    • Chase, J.G.1    Shaw, G.M.2    Lin, J.3
  • 50
    • 0035986130 scopus 로고    scopus 로고
    • Closed-loop control of blood glucose levels in critically ill patients
    • Chee F, Fernando T, van Heerden PV. Closed-loop control of blood glucose levels in critically ill patients. Anaesth Intensive Care. 2002;30:295-307.
    • (2002) Anaesth Intensive Care , vol.30 , pp. 295-307
    • Chee, F.1    Fernando, T.2    van Heerden, P.V.3
  • 51
    • 0025141315 scopus 로고
    • Secondary insults during intrahospital transport of head-injured patients
    • Andrews PJ, Piper IR, Dearden NM, Miller JD. Secondary insults during intrahospital transport of head-injured patients. Lancet. 1990;335:327-330.
    • (1990) Lancet , vol.335 , pp. 327-330
    • Andrews, P.J.1    Piper, I.R.2    Dearden, N.M.3    Miller, J.D.4
  • 52
    • 0031743271 scopus 로고    scopus 로고
    • Secondary insults during intrahospital transport of neurosurgical intensive care patients
    • Bekar A, Ipekoglu Z, Tureyen K, Bilgin H, Korfali G, Korfali E. Secondary insults during intrahospital transport of neurosurgical intensive care patients. Neurosurg Rev. 1998;21:98-101.
    • (1998) Neurosurg Rev , vol.21 , pp. 98-101
    • Bekar, A.1    Ipekoglu, Z.2    Tureyen, K.3    Bilgin, H.4    Korfali, G.5    Korfali, E.6
  • 53
    • 0023636487 scopus 로고
    • Complications of intrahospital transport in critically ill patients
    • Braman SS, Dunn SM, Amico CA, Millman RP. Complications of intrahospital transport in critically ill patients. Ann Intern Med. 1987;107:469-473.
    • (1987) Ann Intern Med , vol.107 , pp. 469-473
    • Braman, S.S.1    Dunn, S.M.2    Amico, C.A.3    Millman, R.P.4
  • 54
    • 0034747218 scopus 로고    scopus 로고
    • Changes in pCO2 during air medical transport of children with closed head injuries
    • Davey AL, Macnab AJ, Green G. Changes in pCO2 during air medical transport of children with closed head injuries. Air Med J. 2001;20:27-30.
    • (2001) Air Med J , vol.20 , pp. 27-30
    • Davey, A.L.1    Macnab, A.J.2    Green, G.3
  • 55
    • 0029964607 scopus 로고    scopus 로고
    • Hypoxemia and arterial hypotension at the accident scene in head injury
    • Stocchetti N, Furlan A, Volta F. Hypoxemia and arterial hypotension at the accident scene in head injury. J Trauma. 1996;40:764-767.
    • (1996) J Trauma , vol.40 , pp. 764-767
    • Stocchetti, N.1    Furlan, A.2    Volta, F.3
  • 56
    • 0035987619 scopus 로고    scopus 로고
    • Alkins SA, Reynolds AJ. Long-distance air evacuation of blast-injured sailors from the U.S.S. Cole. Aviat Space Environ Med. 2002;73:677-680.
    • Alkins SA, Reynolds AJ. Long-distance air evacuation of blast-injured sailors from the U.S.S. Cole. Aviat Space Environ Med. 2002;73:677-680.
  • 58
    • 0029962109 scopus 로고    scopus 로고
    • Implications of automation surprises in aviation for the future of total intravenous anesthesia (TIVA)
    • Cook RI, Woods DD. Implications of automation surprises in aviation for the future of total intravenous anesthesia (TIVA). J Clin Anesth. 1996;8:29S-37S.
    • (1996) J Clin Anesth , vol.8
    • Cook, R.I.1    Woods, D.D.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.