Volumn 95, Issue 4, 2002, Pages 967-972

"Motion-resistant" pulse oximetry: A comparison of new and old models

Author keywords

[No Author keywords available]

Indexed keywords

ARTICLE; BREATHING; HYPOXEMIA; INTERMETHOD COMPARISON; MOTION; PRIORITY JOURNAL; PULSE OXIMETER; PULSE OXIMETRY;

EID: 0036785830     PISSN: 00032999     EISSN: None     Source Type: Journal    
DOI: 10.1097/00000539-200210000-00033     Document Type: Article
Times cited : (164)

References (14)
  • 1
    • 0025781771 scopus 로고
    • A prospective study of intraoperative pulse oximetry failure
    • Freund PR, Overand PT, Cooper J, et al. A prospective study of intraoperative pulse oximetry failure. J Clin Monit 1991;7:253-8.
    • (1991) J Clin Monit , vol.7 , pp. 253-258
    • Freund, P.R.1    Overand, P.T.2    Cooper, J.3
  • 2
    • 0027456512 scopus 로고
    • Randomized evaluation of pulse oximetry in 20,802 patients: I
    • Moller JT, Pederson T, Rasmussen LS, et al. Randomized evaluation of pulse oximetry in 20,802 patients: I. Anesthesiology 1993;78:436-44.
    • (1993) Anesthesiology , vol.78 , pp. 436-444
    • Moller, J.T.1    Pederson, T.2    Rasmussen, L.S.3
  • 3
    • 0028300877 scopus 로고
    • Crying wolf: False alarms in a pediatric intensive care unit
    • Lawless ST. Crying wolf: false alarms in a pediatric intensive care unit. Crit Care Med 1994;22:981-5.
    • (1994) Crit Care Med , vol.22 , pp. 981-985
    • Lawless, S.T.1
  • 4
    • 0025151351 scopus 로고
    • Effect of motion artefact on pulse oximeters: Evaluation of four instruments and finger probes
    • Langton JA, Hanning CD. Effect of motion artefact on pulse oximeters: evaluation of four instruments and finger probes. Br J Anaesth 1990;65:564-70.
    • (1990) Br J Anaesth , vol.65 , pp. 564-570
    • Langton, J.A.1    Hanning, C.D.2
  • 5
    • 0028946818 scopus 로고
    • Evaluation of the influence of movement on saturation readings from pulse oximeters
    • Plummer JL, Zakaria AZ, Ilsley AH, et al. Evaluation of the influence of movement on saturation readings from pulse oximeters. Anaesthesia 1995;50:423-6.
    • (1995) Anaesthesia , vol.50 , pp. 423-426
    • Plummer, J.L.1    Zakaria, A.Z.2    Ilsley, A.H.3
  • 6
    • 0030959233 scopus 로고    scopus 로고
    • Comparison of the Nellcor N-200 and N-3000 pulse oximeters during simulated postoperative activities
    • Lie C, Kehlet H, Rosenberg J. Comparison of the Nellcor N-200 and N-3000 pulse oximeters during simulated postoperative activities. Anaesthesia 1997;52:450-2.
    • (1997) Anaesthesia , vol.52 , pp. 450-452
    • Lie, C.1    Kehlet, H.2    Rosenberg, J.3
  • 7
    • 0031105654 scopus 로고    scopus 로고
    • Identification of movement artefact by the Nellcor N-200 and N-3000 pulse oximeters
    • Plummer JL, Ilsley AH, Fronsko RR, Owen H. Identification of movement artefact by the Nellcor N-200 and N-3000 pulse oximeters. J Clin Monit 1997;13:109-13.
    • (1997) J Clin Monit , vol.13 , pp. 109-113
    • Plummer, J.L.1    Ilsley, A.H.2    Fronsko, R.R.3    Owen, H.4
  • 8
    • 0031027017 scopus 로고    scopus 로고
    • The effects of motion on the performance of pulse oximeters in volunteers
    • Barker SJ, Shah NK. The effects of motion on the performance of pulse oximeters in volunteers. Anesthesiology 1997;86:101-8.
    • (1997) Anesthesiology , vol.86 , pp. 101-108
    • Barker, S.J.1    Shah, N.K.2
  • 9
    • 0000004140 scopus 로고
    • Measurement in medicine: The analysis of method comparison studies
    • Altman DG, Bland JM. Measurement in medicine: the analysis of method comparison studies. Statistician 1983;32:307-17.
    • (1983) Statistician , vol.32 , pp. 307-317
    • Altman, D.G.1    Bland, J.M.2
  • 10
    • 0000007580 scopus 로고    scopus 로고
    • Sensitivity and specificity performance during motion artifact in three pulse oximeters designed for use in motion
    • Jopling MW, Mannheimer PD, Bebout DE. Sensitivity and specificity performance during motion artifact in three pulse oximeters designed for use in motion [abstract]. Anesthesiology 2000; 93(3A):A585.
    • (2000) Anesthesiology , vol.93 , Issue.3 A
    • Jopling, M.W.1    Mannheimer, P.D.2    Bebout, D.E.3
  • 11
    • 0034072367 scopus 로고    scopus 로고
    • Pulse oximeters' reliability in detecting hypoxemia and bradycardia: Comparison between a conventional and two new generation oximeters
    • Bohnhorst B, Peter CS, Poets CF. Pulse oximeters' reliability in detecting hypoxemia and bradycardia: comparison between a conventional and two new generation oximeters. Crit Care Med 2000;28:1565-1568.
    • (2000) Crit Care Med , vol.28 , pp. 1565-1568
    • Bohnhorst, B.1    Peter, C.S.2    Poets, C.F.3
  • 12
    • 0036342147 scopus 로고    scopus 로고
    • Reliability of conventional and new pulse oximetry in neonatal patients
    • Hay WW, Rodden DJ, Collins SM, et al. Reliability of conventional and new pulse oximetry in neonatal patients. J Perinatol 2002;22:360-6.
    • (2002) J Perinatol , vol.22 , pp. 360-366
    • Hay, W.W.1    Rodden, D.J.2    Collins, S.M.3
  • 13
    • 0010511303 scopus 로고    scopus 로고
    • Assessment of two new generation pulse oximeters during low perfusion in children
    • Torres A, Skender K, Wohrley J, et al. Assessment of two new generation pulse oximeters during low perfusion in children [abstract]. Crit Care Med 2001;29:A117.
    • (2001) Crit Care Med , vol.29
    • Torres, A.1    Skender, K.2    Wohrley, J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.