Quality Assurance for the Geometric Accuracy of Cone-Beam CT Guidance in Radiation Therapy

Author keywords

Cone beam CT; Geometric accuracy; Image guidance

Indexed keywords

AMORPHOUS SILICON; LINEAR ACCELERATORS; MEDICAL IMAGING; QUALITY ASSURANCE; RADIOTHERAPY; X RAY TUBES;

EID: 41749120786     PISSN: 03603016     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.ijrobp.2007.06.086     Document Type: Article
Times cited : (68)

References (14)
  • 1
    • 0032866087 scopus 로고    scopus 로고
    • A radiographic and tomographic imaging system integrated into a medical linear accelerator for localization of bone and soft-tissue targets
    • Jaffray D.A., Drake D.G., Moreau M., et al. A radiographic and tomographic imaging system integrated into a medical linear accelerator for localization of bone and soft-tissue targets. Int J Radiat Oncol Biol Phys 45 (1999) 773-789
    • (1999) Int J Radiat Oncol Biol Phys , vol.45 , pp. 773-789
    • Jaffray, D.A.1    Drake, D.G.2    Moreau, M.3
  • 2
    • 30544448340 scopus 로고    scopus 로고
    • X-ray volumetric imaging in image-guided radiotherapy: The new standard in on-treatment imaging
    • McBain C.A., Henry A.M., Sykes J., et al. X-ray volumetric imaging in image-guided radiotherapy: The new standard in on-treatment imaging. Int J Radiat Oncol Biol Phys 64 (2006) 625-634
    • (2006) Int J Radiat Oncol Biol Phys , vol.64 , pp. 625-634
    • McBain, C.A.1    Henry, A.M.2    Sykes, J.3
  • 3
    • 0028230872 scopus 로고
    • Comprehensive QA for radiation oncology: Report of the AAPM Radiation Therapy Committee Task Group 40
    • Kutcher G.J., Coia L., Gillin M., et al. Comprehensive QA for radiation oncology: Report of the AAPM Radiation Therapy Committee Task Group 40. Med Phys 21 (1994) 581-618
    • (1994) Med Phys , vol.21 , pp. 581-618
    • Kutcher, G.J.1    Coia, L.2    Gillin, M.3
  • 5
    • 0003931348 scopus 로고    scopus 로고
    • Mayles W.P.M., Lake R., McKenzie A., et al. (Eds), Institute of Physics and Engineering in Medicine, York, UK
    • In: Mayles W.P.M., Lake R., McKenzie A., et al. (Eds). Physical aspects of quality control in radiotherapy (1999), Institute of Physics and Engineering in Medicine, York, UK
    • (1999) Physical aspects of quality control in radiotherapy
  • 6
    • 41749117667 scopus 로고    scopus 로고
    • X-ray imaging for verification and localization in radiation therapy
    • Van Dyk J. (Ed), Medical Physics, Madison, WI
    • Jaffray D.A., Bissonnette J.-P., and Craig T. X-ray imaging for verification and localization in radiation therapy. In: Van Dyk J. (Ed). The modern technology of radiation oncology Vol. 2 (2005), Medical Physics, Madison, WI 259-284
    • (2005) The modern technology of radiation oncology , vol.2 , pp. 259-284
    • Jaffray, D.A.1    Bissonnette, J.-P.2    Craig, T.3
  • 8
    • 33744794934 scopus 로고    scopus 로고
    • A geometric calibration method for cone beam CT systems
    • Yang K., Kwan A.L., Miller D.F., et al. A geometric calibration method for cone beam CT systems. Med Phys 33 (2006) 1695-1706
    • (2006) Med Phys , vol.33 , pp. 1695-1706
    • Yang, K.1    Kwan, A.L.2    Miller, D.F.3
  • 9
    • 17844380035 scopus 로고    scopus 로고
    • Accurate technique for complete geometric calibration of cone-beam computed tomography systems
    • Cho Y., Moseley D.J., Siewerdsen J.H., et al. Accurate technique for complete geometric calibration of cone-beam computed tomography systems. Med Phys 32 (2005) 968-983
    • (2005) Med Phys , vol.32 , pp. 968-983
    • Cho, Y.1    Moseley, D.J.2    Siewerdsen, J.H.3
  • 10
    • 0023875610 scopus 로고
    • A system for stereotactic radiosurgery with a linear accelerator
    • Lutz W., Winston K.R., and Maleki N. A system for stereotactic radiosurgery with a linear accelerator. Int J Radiat Oncol Biol Phys 14 (1988) 373-381
    • (1988) Int J Radiat Oncol Biol Phys , vol.14 , pp. 373-381
    • Lutz, W.1    Winston, K.R.2    Maleki, N.3
  • 11
    • 31044444873 scopus 로고    scopus 로고
    • The stability of mechanical calibration for a kV cone beam computed tomography system integrated with linear accelerator
    • Sharpe M.B., Moseley D.J., Purdie T.G., et al. The stability of mechanical calibration for a kV cone beam computed tomography system integrated with linear accelerator. Med Phys 33 (2006) 136-144
    • (2006) Med Phys , vol.33 , pp. 136-144
    • Sharpe, M.B.1    Moseley, D.J.2    Purdie, T.G.3
  • 12
    • 41749110844 scopus 로고    scopus 로고
    • Performance and stability of the Varian Cone-Beam CT system
    • Kim G., Pawlicki T., and Luxton G. Performance and stability of the Varian Cone-Beam CT system. Med Phys 33 (2006) 2004
    • (2006) Med Phys , vol.33 , pp. 2004
    • Kim, G.1    Pawlicki, T.2    Luxton, G.3
  • 13
    • 41749100996 scopus 로고    scopus 로고
    • Quantifying the Geometric accuracy of the On Board Imager over a one-year period
    • Lovelock D., LoSasso T., Ali I., et al. Quantifying the Geometric accuracy of the On Board Imager over a one-year period. Med Phys 33 (2006) 2000-2001
    • (2006) Med Phys , vol.33 , pp. 2000-2001
    • Lovelock, D.1    LoSasso, T.2    Ali, I.3
  • 14
    • 0036680147 scopus 로고    scopus 로고
    • Flat-panel cone-beam computed tomography for image-guided radiation therapy
    • Jaffray D.A., Siewerdsen J.H., Wong J.W., et al. Flat-panel cone-beam computed tomography for image-guided radiation therapy. Int J Radiat Oncol Biol Phys 53 (2002) 1337-1349
    • (2002) Int J Radiat Oncol Biol Phys , vol.53 , pp. 1337-1349
    • Jaffray, D.A.1    Siewerdsen, J.H.2    Wong, J.W.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.