메뉴 건너뛰기




Volumn 35, Issue 5, 2008, Pages 613-617

Effects of non-Newtonian fluid on centrifugal blood pump performance

Author keywords

Aqueous Xanthan gum solution; Centrifugal blood pump; Pump performance; Rheological property; Similarity law

Indexed keywords

FLOW RATE; IMPELLERS; NON NEWTONIAN LIQUIDS; RHEOLOGY;

EID: 41649109588     PISSN: 07351933     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.icheatmasstransfer.2007.11.005     Document Type: Article
Times cited : (18)

References (16)
  • 1
    • 0033938026 scopus 로고    scopus 로고
    • Blood pumps for circulatory support
    • Hlemut M.R., and Mustafa A. Blood pumps for circulatory support. Perfusion 15 (2000) 295-311
    • (2000) Perfusion , vol.15 , pp. 295-311
    • Hlemut, M.R.1    Mustafa, A.2
  • 3
    • 0025075989 scopus 로고
    • Flow of non-Newtonian blood analog fluids in rigid curved and straight artery models
    • Mann D.E., and Tarbell J.M. Flow of non-Newtonian blood analog fluids in rigid curved and straight artery models. Biorheology 27 7 (1990) 711-733
    • (1990) Biorheology , vol.27 , Issue.7 , pp. 711-733
    • Mann, D.E.1    Tarbell, J.M.2
  • 4
    • 0027199146 scopus 로고
    • Evaluation of a transparent blood analog fluid: aqueous Xanthan gum/glycerin
    • Brookshier K.A., and Tarbell J.M. Evaluation of a transparent blood analog fluid: aqueous Xanthan gum/glycerin. Biorheology 30 22 (1993) 107-116
    • (1993) Biorheology , vol.30 , Issue.22 , pp. 107-116
    • Brookshier, K.A.1    Tarbell, J.M.2
  • 5
    • 41649119275 scopus 로고    scopus 로고
    • D.S. Miklosovic, An experimental evaluation of the non-Newtonian scaling effects in a rotodynamic left ventricular assist device, PHD thesis, The Ohio University, Columbus, Ohio, 1999.
    • D.S. Miklosovic, An experimental evaluation of the non-Newtonian scaling effects in a rotodynamic left ventricular assist device, PHD thesis, The Ohio University, Columbus, Ohio, 1999.
  • 6
    • 0034173954 scopus 로고    scopus 로고
    • Measurements of gap pressure and wall shear stress of a blood pump model
    • Chua L.P., and Akamatsu T. Measurements of gap pressure and wall shear stress of a blood pump model. Medical Engineering & Physics 22 (2000) 175-188
    • (2000) Medical Engineering & Physics , vol.22 , pp. 175-188
    • Chua, L.P.1    Akamatsu, T.2
  • 8
    • 0033117922 scopus 로고    scopus 로고
    • Comparison of flow characteristics of enlarged blood pump models with different impeller design
    • Chua L.P., Yu S.C.M., Leo H.L., and Chan W.K. Comparison of flow characteristics of enlarged blood pump models with different impeller design. Heat mass transfer 26 3 (1999) 369-378
    • (1999) Heat mass transfer , vol.26 , Issue.3 , pp. 369-378
    • Chua, L.P.1    Yu, S.C.M.2    Leo, H.L.3    Chan, W.K.4
  • 9
    • 0023152367 scopus 로고
    • An experimental study of Newtonian and non-Newtonian flow dynamics in a ventricular assist device
    • Mann K.A., and Deutsch S. An experimental study of Newtonian and non-Newtonian flow dynamics in a ventricular assist device. Journal of Biomechanical Engineering 109 (1987) 139-147
    • (1987) Journal of Biomechanical Engineering , vol.109 , pp. 139-147
    • Mann, K.A.1    Deutsch, S.2
  • 10
    • 0032230919 scopus 로고    scopus 로고
    • Development of a centrifugal blood pump with magnetically suspended impeller and the related fluid mechanical problems
    • Akamatsu T., and Tsukiya T. Development of a centrifugal blood pump with magnetically suspended impeller and the related fluid mechanical problems. Indian Academy of Sciences 23 5 (1998) 597-603
    • (1998) Indian Academy of Sciences , vol.23 , Issue.5 , pp. 597-603
    • Akamatsu, T.1    Tsukiya, T.2
  • 11
    • 0029142494 scopus 로고
    • Recent studies of the centrifugal blood pump with a magnetically suspended impeller
    • Akamatsu T., Tsukiya T., and Nishimura K. Recent studies of the centrifugal blood pump with a magnetically suspended impeller. Artificial Organs 19 7 (1995) 631-634
    • (1995) Artificial Organs , vol.19 , Issue.7 , pp. 631-634
    • Akamatsu, T.1    Tsukiya, T.2    Nishimura, K.3
  • 13
    • 34547332078 scopus 로고    scopus 로고
    • Experimental investigation of rheological properties of blood and Xanthan gum solutions as a blood analog fluid
    • Zhang G.G., Zhang M.Y., Yang W.Y., and Zhu X.R. Experimental investigation of rheological properties of blood and Xanthan gum solutions as a blood analog fluid. Journal of Experiments in Fluid Mechanics 21 2 (2007) 21-24
    • (2007) Journal of Experiments in Fluid Mechanics , vol.21 , Issue.2 , pp. 21-24
    • Zhang, G.G.1    Zhang, M.Y.2    Yang, W.Y.3    Zhu, X.R.4
  • 14
    • 0026283109 scopus 로고
    • Effect of the non-Newtonian viscosity of blood on steady and pulsatile flow in stenosed arteries
    • Banerjee R.K., Yong I.C., and Kenneth K. Effect of the non-Newtonian viscosity of blood on steady and pulsatile flow in stenosed arteries. Advances in bioengineering 20 (1991) 103-106
    • (1991) Advances in bioengineering , vol.20 , pp. 103-106
    • Banerjee, R.K.1    Yong, I.C.2    Kenneth, K.3
  • 16
    • 0039261823 scopus 로고
    • Rheological and drag reduction characteristics of Xanthan gum solutions
    • Bewersdorff H.W., and Singh R.P. Rheological and drag reduction characteristics of Xanthan gum solutions. Rheologica Acta 27 6 (1988) 617-627
    • (1988) Rheologica Acta , vol.27 , Issue.6 , pp. 617-627
    • Bewersdorff, H.W.1    Singh, R.P.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.