Volumn 17, Issue 3, 2008, Pages 201-210

Mechanical behavior and failure analysis of prosthetic retaining screws after long-term use in vivo. Part 4: Failure analysis of 10 fractured retaining screws retrieved from three patients

Author keywords

Crack propagation; Ductile fracture; Failure analysis; Fatigue failure; Fatigue striations; Prosthetic screw failure; Ratchet marks

Indexed keywords

DENTAL ALLOY;

EID: 41649100086     PISSN: 1059941X     EISSN: 1532849X     Source Type: Journal    
DOI: 10.1111/j.1532-849X.2007.00291.x     Document Type: Article
Times cited : (21)

References (26)
  • 1
    • 0025583364 scopus 로고
    • Long-term follow-up of osseointegrated implants in the treatment of totally edentulous jaws
    • Adell R, Erickson B, Lekholm U, et al : Long-term follow-up of osseointegrated implants in the treatment of totally edentulous jaws. Int J Oral Maxillofac Implants 1990 5 : 347 359
    • (1990) Int J Oral Maxillofac Implants , vol.5 , pp. 347-359
    • Adell, R.1    Erickson, B.2    Lekholm, U.3
  • 2
    • 0029303274 scopus 로고
    • Bending overload and implant fracture: A retrospective clinical analysis
    • Rangert B, Krogh PH, Langer BM, et al : Bending overload and implant fracture: a retrospective clinical analysis. Int J Oral Maxillofac Implants 1995 10 : 326 334
    • (1995) Int J Oral Maxillofac Implants , vol.10 , pp. 326-334
    • Rangert, B.1    Krogh, P.H.2    Langer, B.M.3
  • 3
    • 0028390316 scopus 로고
    • Loose gold screws frequently occur in full-arch fixed prostheses supported by osseointegrated implants
    • Kallus T, Bessing C : Loose gold screws frequently occur in full-arch fixed prostheses supported by osseointegrated implants. Int J Oral Maxillofac Implants 1994 9 : 169 178
    • (1994) Int J Oral Maxillofac Implants , vol.9 , pp. 169-178
    • Kallus, T.1    Bessing, C.2
  • 4
    • 0025471133 scopus 로고
    • The longitudinal clinical effectiveness of osseointegrated dental implants: The Toronto study. Part III: Problems and complications encountered
    • Zarb GA, Schmitt A : The longitudinal clinical effectiveness of osseointegrated dental implants: the Toronto study. Part III: problems and complications encountered. J Prosthet Dent 1990 64 : 185 194
    • (1990) J Prosthet Dent , vol.64 , pp. 185-194
    • Zarb, G.A.1    Schmitt, A.2
  • 6
    • 0026218667 scopus 로고
    • Failure and complications in 391 consecutively inserted fixed prostheses supported by Branemark implants in edentulous jaws. A study of treatment from the time of prosthesis placement to the first annual checkup
    • Jemt T : Failure and complications in 391 consecutively inserted fixed prostheses supported by Branemark implants in edentulous jaws. A study of treatment from the time of prosthesis placement to the first annual checkup. Int J Oral Maxillofac Implants 1991 6 : 270 276
    • (1991) Int J Oral Maxillofac Implants , vol.6 , pp. 270-276
    • Jemt, T.1
  • 7
    • 0027015903 scopus 로고
    • A study of 589 consecutive implants supporting complete fixed prostheses. Part II: Prosthetic aspects
    • Naert I : A study of 589 consecutive implants supporting complete fixed prostheses. Part II: prosthetic aspects. J Prosthet Dent 1992 68 : 949 956
    • (1992) J Prosthet Dent , vol.68 , pp. 949-956
    • Naert, I.1
  • 8
    • 0029261651 scopus 로고
    • Registration of localization, occlusion and occluding materials for failing screw joints in the Branemark implant system
    • Wie H : Registration of localization, occlusion and occluding materials for failing screw joints in the Branemark implant system. Clin Oral Implants Res 1995 6 : 47 53
    • (1995) Clin Oral Implants Res , vol.6 , pp. 47-53
    • Wie, H.1
  • 11
    • 0031609120 scopus 로고    scopus 로고
    • Prosthodontic problems and limitations associated with osseointegration
    • Taylor TD : Prosthodontic problems and limitations associated with osseointegration. J Prosthet Dent 1998 79 : 74 78
    • (1998) J Prosthet Dent , vol.79 , pp. 74-78
    • Taylor, T.D.1
  • 12
    • 0039977028 scopus 로고
    • External strain distribution on implant prosthetic components
    • Abstract 1045
    • Sakaguchi RL, Sun T, Haack JE : External strain distribution on implant prosthetic components. J Dent Res 1994 73 : 232. Abstract 1045
    • (1994) J Dent Res , vol.73 , pp. 232
    • Sakaguchi, R.L.1    Sun, T.2    Haack, J.E.3
  • 13
    • 0036885837 scopus 로고    scopus 로고
    • Fatigue resistance of two implant/abutment joint designs
    • Khraisat A, Stegaroiu R, Nomura S, et al : Fatigue resistance of two implant/abutment joint designs. J Prosthet Dent 2002 88 : 604 610
    • (2002) J Prosthet Dent , vol.88 , pp. 604-610
    • Khraisat, A.1    Stegaroiu, R.2    Nomura, S.3
  • 14
    • 85047681494 scopus 로고    scopus 로고
    • Micromotion and dynamic fatigue properties of the dental implant-abutment interface
    • Gratton DG, Aquilino SA, Stanford CM : Micromotion and dynamic fatigue properties of the dental implant-abutment interface. J Prosthet Dent 2001 85 : 47 52
    • (2001) J Prosthet Dent , vol.85 , pp. 47-52
    • Gratton, D.G.1    Aquilino, S.A.2    Stanford, C.M.3
  • 15
    • 0036781641 scopus 로고    scopus 로고
    • Wave analysis of implant screw loosening using an air cylindrical cyclic loading device
    • Lee J, Kim Y, Kim C, et al : Wave analysis of implant screw loosening using an air cylindrical cyclic loading device. J Prosthet Dent 2002 88 : 402 408
    • (2002) J Prosthet Dent , vol.88 , pp. 402-408
    • Lee, J.1    Kim, Y.2    Kim, C.3
  • 16
    • 0035375020 scopus 로고    scopus 로고
    • Dynamic fatigue properties of the dental implant-abutment interface joint opening in wide-diameter versus standard-diameter hex-type implants
    • Hoyer SA, Stanford CM, Buranadham S, et al : Dynamic fatigue properties of the dental implant-abutment interface joint opening in wide-diameter versus standard-diameter hex-type implants. J Prosthet Dent 2001 85 : 599 607
    • (2001) J Prosthet Dent , vol.85 , pp. 599-607
    • Hoyer, S.A.1    Stanford, C.M.2    Buranadham, S.3
  • 17
    • 0035290987 scopus 로고    scopus 로고
    • Examination of the implant-abutment interface after fatigue testing
    • Cibirka RM, Nelson SK, Lang B, et al : Examination of the implant-abutment interface after fatigue testing. J Prosthet Dent 2001 85 : 268 275
    • (2001) J Prosthet Dent , vol.85 , pp. 268-275
    • Cibirka, R.M.1    Nelson, S.K.2    Lang, B.3
  • 18
    • 33644480134 scopus 로고
    • Failure analysis and prevention
    • 4th printing
    • Failure analysis and prevention. ASM Handbook, volume 11, 4th printing, 1992
    • (1992) ASM Handbook , vol.11
  • 21
    • 0029261525 scopus 로고
    • Vertical load distribution on a three-unit prosthesis supported by a natural tooth and single Branemark implant
    • Rangert B, Gunne J, Glantz PO, et al : Vertical load distribution on a three-unit prosthesis supported by a natural tooth and single Branemark implant. Clin Oral Implants Res 1995 6 : 40 46
    • (1995) Clin Oral Implants Res , vol.6 , pp. 40-46
    • Rangert, B.1    Gunne, J.2    Glantz, P.O.3
  • 22
    • 0033630481 scopus 로고    scopus 로고
    • Biomaterials and biomechanics of oral and maxillofacial implants: Current status and future developments
    • Brunski J, Puleo D, Nanci A : Biomaterials and biomechanics of oral and maxillofacial implants: current status and future developments. Int J Oral Maxillofac Implants 2000 15 : 15 38
    • (2000) Int J Oral Maxillofac Implants , vol.15 , pp. 15-38
    • Brunski, J.1    Puleo, D.2    Nanci, A.3
  • 23
    • 0024623750 scopus 로고
    • Occlusal force pattern in dentition with mandibular implant supported fixed cantilever prostheses occluded with complete dentures
    • Falk H, Laurell L, Lundgren D : Occlusal force pattern in dentition with mandibular implant supported fixed cantilever prostheses occluded with complete dentures. Int J Oral Maxillofac Implants 1989 4 : 55 61
    • (1989) Int J Oral Maxillofac Implants , vol.4 , pp. 55-61
    • Falk, H.1    Laurell, L.2    Lundgren, D.3
  • 24
    • 0024836867 scopus 로고
    • The influence of number and distribution of occlusal cantilever contacts on closing and chewing forces in dentitions with implant-supported fixed prostheses occluding with complete dentures
    • Lundgren D, Falk H, Laurell L : The influence of number and distribution of occlusal cantilever contacts on closing and chewing forces in dentitions with implant-supported fixed prostheses occluding with complete dentures. Int J Oral Maxillofac Implants 1989 4 : 277 283
    • (1989) Int J Oral Maxillofac Implants , vol.4 , pp. 277-283
    • Lundgren, D.1    Falk, H.2    Laurell, L.3
  • 26
    • 0030089626 scopus 로고    scopus 로고
    • Ultimate tensile strength of five interchangeable prosthetic retaining screws
    • Jaarda M, Razzoog M, Gratton D : Ultimate tensile strength of five interchangeable prosthetic retaining screws. Implant Dent 1996 5 : 16 19
    • (1996) Implant Dent , vol.5 , pp. 16-19
    • Jaarda, M.1    Razzoog, M.2    Gratton, D.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.