메뉴 건너뛰기




Volumn 8, Issue 6, 2003, Pages 261-265

Validation of the ROSSMAX blood pressure measuring monitor according to the European Society of Hypertension International Protocol for Validation of Blood Pressure Measuring Devices in Adults

Author keywords

Accuracy; Adult; European Society of Hypertension validation; International Protocol; ROSSMAX; Self measurement

Indexed keywords

ADULT; AGED; ANTHROPOMETRY; ARM; ARTICLE; AUDIOVISUAL EQUIPMENT; BLOOD PRESSURE MEASUREMENT; BLOOD PRESSURE MONITORING; CONTROLLED STUDY; DEMOGRAPHY; DIASTOLIC BLOOD PRESSURE; FEMALE; HUMAN; HUMAN EXPERIMENT; MALE; MEDICAL SOCIETY; MONITOR; PRIORITY JOURNAL; RECUMBENCY; SELF EXAMINATION; SPHYGMOCORDER; SPHYGMOMANOMETER; SYSTOLIC BLOOD PRESSURE; TAPE RECORDER; VALIDATION PROCESS; VIDEORECORDING;

EID: 4143143048     PISSN: 13595237     EISSN: None     Source Type: Journal    
DOI: 10.1097/00126097-200312000-00007     Document Type: Article
Times cited : (5)

References (8)
  • 1
    • 0035799041 scopus 로고    scopus 로고
    • Blood pressure measuring devices: Validated instruments
    • O'Brien E, Waeber B, Parati G, Staessen G, Myers MG on behalf of the European Society of Hypertension Working Group on Blood Pressure Monitoring. Blood pressure measuring devices: validated instruments. BMJ 2001; 322:531-536.
    • (2001) BMJ , vol.322 , pp. 531-536
    • O'Brien, E.1    Waeber, B.2    Parati, G.3    Staessen, G.4    Myers, M.G.5
  • 3
    • 0025071770 scopus 로고
    • The British Hypertension Society Protocol for the evaluation of automated and semi-automated blood pressure measuring devices with special reference to ambulatory systems
    • O'Brien E, Petrie J, Littler W, de Swiet M, Padfield PL, O'Malley K, et al. The British Hypertension Society Protocol for the evaluation of automated and semi-automated blood pressure measuring devices with special reference to ambulatory systems. J Hypertens 1990; 8:607-619.
    • (1990) J Hypertens , vol.8 , pp. 607-619
    • O'Brien, E.1    Petrie, J.2    Littler, W.3    De Swiet, M.4    Padfield, P.L.5    O'Malley, K.6
  • 4
    • 0027218269 scopus 로고
    • The British Hypertension Society Protocol for the evaluation of blood pressure measuring devices
    • O'Brien E, Petrie J, Littler WA, de Swiet M, Padfield PL, Altman D, et al. The British Hypertension Society Protocol for the evaluation of blood pressure measuring devices. J Hypertens 1993; 11(suppl 2):S43-S63.
    • (1993) J Hypertens , vol.11 , Issue.2 SUPPL.
    • O'Brien, E.1    Petrie, J.2    Littler, W.A.3    De Swiet, M.4    Padfield, P.L.5    Altman, D.6
  • 6
    • 0028129011 scopus 로고
    • A comparison of the BHS and AAMI protocols for validating blood pressure measuring devices: Can the two be reconciled?
    • O'Brien E, Atkins N. A comparison of the BHS and AAMI protocols for validating blood pressure measuring devices: can the two be reconciled? J Hypertens 1994; 12:1089-1094.
    • (1994) J Hypertens , vol.12 , pp. 1089-1094
    • O'Brien, E.1    Atkins, N.2
  • 7
    • 0035992025 scopus 로고    scopus 로고
    • International protocol for validation of blood pressure measuring devices in adults
    • O'Brien E, Pickering T, Asmar R, Myers M, Parati G, Staessen J, et al. with the statistical assistance of Atkins N and Gerin W on behalf of the Working Group on Blood Pressure Monitoring of the European Society of Hypertension. International protocol for validation of blood pressure measuring devices in adults. Blood Press Monit 2002; 7:3-17.
    • (2002) Blood Press Monit , vol.7 , pp. 3-17
    • O'Brien, E.1    Pickering, T.2    Asmar, R.3    Myers, M.4    Parati, G.5    Staessen, J.6    Atkins, N.7    Gerin, W.8
  • 8
    • 0029560740 scopus 로고
    • A new audio-visual technique for recording blood pressure in research: The Sphygmocorder
    • O'Brien E, Atkins N, Mee F, Coyle D, Syed S. A new audio-visual technique for recording blood pressure in research: the Sphygmocorder. J Hypertens 1995; 13:1734-1737.
    • (1995) J Hypertens , vol.13 , pp. 1734-1737
    • O'Brien, E.1    Atkins, N.2    Mee, F.3    Coyle, D.4    Syed, S.5