메뉴 건너뛰기




Volumn 32, Issue 4, 2008, Pages 283-291

The influence of the loading mode on the stress distribution on the connector region of metal-ceramic and all-ceramic fixed partial denture

Author keywords

Finite element analysis; Fixed partial dentures; Metal ceramic restorations; Stress analysis; Stress fractures

Indexed keywords

DENTAL PROSTHESES; FILLING; FRACTURE; METALS; PORCELAIN; STRESS ANALYSIS; STRESS CONCENTRATION; TENSILE STRESS; VENEERS;

EID: 41149160657     PISSN: 0160564X     EISSN: 15251594     Source Type: Journal    
DOI: 10.1111/j.1525-1594.2008.00544.x     Document Type: Article
Times cited : (31)

References (25)
  • 1
    • 0037364451 scopus 로고    scopus 로고
    • Fracture reasons in ceramic-fused-to-metal restorations
    • Özcan M. Fracture reasons in ceramic-fused-to-metal restorations. J Oral Rehabil 2003 30 : 265 9.
    • (2003) J Oral Rehabil , vol.30 , pp. 265-269
    • Özcan, M.1
  • 3
    • 0037812257 scopus 로고    scopus 로고
    • A long-term retrospective and clinical follow-up study of In-Ceram Alumina FPDs
    • Olsson KG, Furst B, Andersson B, Carlsson GE. A long-term retrospective and clinical follow-up study of In-Ceram Alumina FPDs. Int J Prosthodont 2003 16 : 150 6.
    • (2003) Int J Prosthodont , vol.16 , pp. 150-156
    • Olsson, K.G.1    Furst, B.2    Andersson, B.3    Carlsson, G.E.4
  • 4
    • 0022774365 scopus 로고
    • A clinical evaluation of fixed bridges, 10 years following insertion
    • Karlsson S. A clinical evaluation of fixed bridges, 10 years following insertion. J Oral Rehabil 1986 13 : 423 32.
    • (1986) J Oral Rehabil , vol.13 , pp. 423-432
    • Karlsson, S.1
  • 5
    • 0027604533 scopus 로고
    • Artificial crowns and fixed partial dentures 18 to 23 years after placement
    • Palmqvist S, Swartz B. Artificial crowns and fixed partial dentures 18 to 23 years after placement. Int J Prosthodont 1993 6 : 279 85.
    • (1993) Int J Prosthodont , vol.6 , pp. 279-285
    • Palmqvist, S.1    Swartz, B.2
  • 6
    • 0032016055 scopus 로고    scopus 로고
    • Success rate and failures for fixed partial dentures after 20 years of service: Part I
    • Lindquist E, Karlsson S. Success rate and failures for fixed partial dentures after 20 years of service: part I. Int J Prosthodont 1998 11 : 133 8.
    • (1998) Int J Prosthodont , vol.11 , pp. 133-138
    • Lindquist, E.1    Karlsson, S.2
  • 7
    • 0004274342 scopus 로고    scopus 로고
    • Fatigue crack growth in brittle solids
    • In: Suresh, S., ed. Edition. Cambridge, UK: Cambridge University Press
    • Suresh S. Fatigue crack growth in brittle solids. In : Suresh S, ed. Fatigue of Materials, 2nd Edition. Cambridge, UK : Cambridge University Press, 1998 383 407.
    • (1998) Fatigue of Materials, 2nd , pp. 383-407
    • Suresh, S.1
  • 9
    • 0022764552 scopus 로고
    • Technical failures and some related clinical complications in extensive fixed prosthodontics. An epidemiological study of long-term clinical quality
    • Randow K, Glantz PO, Zoger B. Technical failures and some related clinical complications in extensive fixed prosthodontics. An epidemiological study of long-term clinical quality. Acta Odontol Scand 1986 44 : 241 55.
    • (1986) Acta Odontol Scand , vol.44 , pp. 241-255
    • Randow, K.1    Glantz, P.O.2    Zoger, B.3
  • 10
    • 0036560045 scopus 로고    scopus 로고
    • Effect of connector design on the fracture resistance of all-ceramic fixed partial dentures
    • Oh WS, Anusavice KJ. Effect of connector design on the fracture resistance of all-ceramic fixed partial dentures. J Prosthet Dent 2002 87 : 536 42.
    • (2002) J Prosthet Dent , vol.87 , pp. 536-542
    • Oh, W.S.1    Anusavice, K.J.2
  • 13
    • 0032013518 scopus 로고    scopus 로고
    • Relevance of the finite element method to optimize fixed partial denture design. Part I. Influence of the size of the connector on the magnitude of strain
    • Argereau D, Pierrisnard L, Barquins M. Relevance of the finite element method to optimize fixed partial denture design. Part I. Influence of the size of the connector on the magnitude of strain. Clin Oral Invest 1998 2 : 36 9.
    • (1998) Clin Oral Invest , vol.2 , pp. 36-39
    • Argereau, D.1    Pierrisnard, L.2    Barquins, M.3
  • 14
  • 15
    • 4944247307 scopus 로고    scopus 로고
    • Dimensions of metal framework components of metal-ceramic fixed partial dentures constructed in a dental school setting
    • Ridwaan O, Abduljabbar T, Al-Ali K, Smyth M, El-Agouri R. Dimensions of metal framework components of metal-ceramic fixed partial dentures constructed in a dental school setting. Quintessence Int 2004 35 : 820 5.
    • (2004) Quintessence Int , vol.35 , pp. 820-825
    • Ridwaan, O.1    Abduljabbar, T.2    Al-Ali, K.3    Smyth, M.4    El-Agouri, R.5
  • 17
    • 9744245356 scopus 로고    scopus 로고
    • Finite element analysis of fixed partial denture replacement
    • Romeed SA, Fok SL, Wilson NHF. Finite element analysis of fixed partial denture replacement. J Oral Rehabil 2004 31 : 1208 17.
    • (2004) J Oral Rehabil , vol.31 , pp. 1208-1217
    • Romeed, S.A.1    Fok, S.L.2    Wilson, N.H.F.3
  • 18
    • 0024836867 scopus 로고
    • Influence of number and distribution of occlusal cantilever contacts on closing and chewing forces in dentitions with implant-supported fixed prostheses occluding with complete dentures
    • Lundgren D, Falk H, Laurell L. Influence of number and distribution of occlusal cantilever contacts on closing and chewing forces in dentitions with implant-supported fixed prostheses occluding with complete dentures. Int J Oral Maxillofac Implants 1989 4 : 277 83.
    • (1989) Int J Oral Maxillofac Implants , vol.4 , pp. 277-283
    • Lundgren, D.1    Falk, H.2    Laurell, L.3
  • 19
    • 0034186662 scopus 로고    scopus 로고
    • Influence of design and mode of loading on the fracture strength of all-ceramic resin-bonded fixed partial dentures: An in vitro study in a dual-axis chewing simulator
    • Koutayas SO, Kern M, Ferraresso F, Strub JR. Influence of design and mode of loading on the fracture strength of all-ceramic resin-bonded fixed partial dentures: an in vitro study in a dual-axis chewing simulator. J Prosthet Dent 2000 83 : 540 7.
    • (2000) J Prosthet Dent , vol.83 , pp. 540-547
    • Koutayas, S.O.1    Kern, M.2    Ferraresso, F.3    Strub, J.R.4
  • 21
    • 4444273151 scopus 로고    scopus 로고
    • Undermining of enamel as a mechanism of abfraction lesion formation: A finite element study
    • Rees JS, Hammadeh M. Undermining of enamel as a mechanism of abfraction lesion formation: a finite element study. Eur J Oral Sci 2004 112 : 347 52.
    • (2004) Eur J Oral Sci , vol.112 , pp. 347-352
    • Rees, J.S.1    Hammadeh, M.2
  • 22
    • 0036834104 scopus 로고    scopus 로고
    • Stress distribution associated with loaded acrylic-metal-cement crowns by using finite element method
    • Toparli M, Aykul H, Aksoy T. Stress distribution associated with loaded acrylic-metal-cement crowns by using finite element method. J Oral Rehabil 2002 29 : 1108 14.
    • (2002) J Oral Rehabil , vol.29 , pp. 1108-1114
    • Toparli, M.1    Aykul, H.2    Aksoy, T.3
  • 23
    • 1942521365 scopus 로고    scopus 로고
    • Influence of occlusal forces on stress distribution in preloaded dental implant screws
    • Ibrahim A, Sertgöz A, Ekici B. Influence of occlusal forces on stress distribution in preloaded dental implant screws. J Prosthet Dent 2004 91 : 319 25.
    • (2004) J Prosthet Dent , vol.91 , pp. 319-325
    • Ibrahim, A.1    Sertgöz, A.2    Ekici, B.3
  • 25
    • 22444450165 scopus 로고    scopus 로고
    • 3D FEA of cemented steel, glass and carbon posts in a maxillary incisor
    • Lanza A, Aversa R, Rengo S, Apicella D, Apicella A. 3D FEA of cemented steel, glass and carbon posts in a maxillary incisor. Dent Mater 2005 21 : 709 15.
    • (2005) Dent Mater , vol.21 , pp. 709-715
    • Lanza, A.1    Aversa, R.2    Rengo, S.3    Apicella, D.4    Apicella, A.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.