메뉴 건너뛰기




Volumn 4, Issue 1, 2008, Pages 32-45

Erratum: Image enhanced surgical navigation for endoscopic sinus surgery: Evaluating calibration, registration and tracking (The International Journal of Robotics and Computer Assisted Surgery (2007) vol. 4 (32-45) 10.1002/rcs.175);Image-enhanced surgical navigation for endoscopic sinus surgery: Evaluating calibration, registration and tracking

Author keywords

Augmented reality; Endoscopic sinus surgery; Image enhancement; Image guided surgery; Surgical navigation

Indexed keywords

AUGMENTED REALITY; CALIBRATION; COMPUTERIZED TOMOGRAPHY; DEPTH PERCEPTION; ERRORS; IMAGE ENHANCEMENT; IMAGE SEGMENTATION; NAVIGATION; STEREO IMAGE PROCESSING; SURGERY;

EID: 41149126765     PISSN: 14785951     EISSN: 1478596X     Source Type: Journal    
DOI: 10.1002/rcs.199     Document Type: Erratum
Times cited : (40)

References (21)
  • 1
    • 0029422544 scopus 로고
    • Augmentation of reality in the stereo operating microscope for otolaryngology and neurosurgical guidance
    • Edwards P, Hawkes D, Hill D, et al. Augmentation of reality in the stereo operating microscope for otolaryngology and neurosurgical guidance. J Comput Assist Surg 1995; 1(3): 172-178.
    • (1995) J Comput Assist Surg , vol.1 , Issue.3 , pp. 172-178
    • Edwards, P.1    Hawkes, D.2    Hill, D.3
  • 2
    • 0034310514 scopus 로고    scopus 로고
    • Design and evaluation of a system for microscope-assisted guided interventions (MAGI)
    • Edwards PJ, King AP, Maurer CR, et al. Design and evaluation of a system for microscope-assisted guided interventions (MAGI). IEEE Trans Med Imag 2000; 19(11): 1082-1093.
    • (2000) IEEE Trans Med Imag , vol.19 , Issue.11 , pp. 1082-1093
    • Edwards, P.J.1    King, A.P.2    Maurer, C.R.3
  • 3
    • 0030386420 scopus 로고    scopus 로고
    • Technologies for augmented reality systems: Realizing ultrasound-guided needle biopsies
    • State A, Livingston MA, Hirota G, et al. Technologies for augmented reality systems: realizing ultrasound-guided needle biopsies. Proc SIGGRAPH 1996; 439-446.
    • (1996) Proc SIGGRAPH , pp. 439-446
    • State, A.1    Livingston, M.A.2    Hirota, G.3
  • 4
    • 0026888256 scopus 로고
    • Merging virtual objects with the real world: Seeing ultrasound imagery within the patient
    • Bajura M, Fuchs H, Ohbuchi R. Merging virtual objects with the real world: Seeing ultrasound imagery within the patient. Comput Graphics 1992; 26(2): 203-209.
    • (1992) Comput Graphics , vol.26 , Issue.2 , pp. 203-209
    • Bajura, M.1    Fuchs, H.2    Ohbuchi, R.3
  • 5
    • 84947815217 scopus 로고    scopus 로고
    • Assessment of several virtual endoscopy techniques using computed tomography and perspective volume rendering. Visualization in Biomedical Computing (VBC'96)
    • Shahidi R, Argiro V, Napel S, et al. Assessment of several virtual endoscopy techniques using computed tomography and perspective volume rendering. Visualization in Biomedical Computing (VBC'96) LNCS 1131, 1996; 521-528.
    • (1996) LNCS , vol.1131 , pp. 521-528
    • Shahidi, R.1    Argiro, V.2    Napel, S.3
  • 6
    • 84929924561 scopus 로고    scopus 로고
    • Volumetric image navigation through stereotactic endoscopes. Proceedings of Medical Image Computing and Computer-Assisted Intervention (MICCAI'98, LNCS, 1496)
    • Shahidi R, Wang B, Epitaux M, et al. Volumetric image navigation through stereotactic endoscopes. Proceedings of Medical Image Computing and Computer-Assisted Intervention (MICCAI'98, LNCS, 1496), Conference, 1998; 241-252.
    • (1998) Conference , pp. 241-252
    • Shahidi, R.1    Wang, B.2    Epitaux, M.3
  • 7
    • 0037001791 scopus 로고    scopus 로고
    • Implementation, calibration and accuracy testing of an image-enhanced endoscopy system
    • Shahidi R, Bax MR, Maurer CR. Implementation, calibration and accuracy testing of an image-enhanced endoscopy system. IEEE Trans Med Imag 2002; 21(12): 1524-1535.
    • (2002) IEEE Trans Med Imag , vol.21 , Issue.12 , pp. 1524-1535
    • Shahidi, R.1    Bax, M.R.2    Maurer, C.R.3
  • 8
    • 0036055260 scopus 로고    scopus 로고
    • Image-enhanced endoscopy calibration and image registration accuracy testing
    • Bax MR, Khadem R, Johnson JA, et al. Image-enhanced endoscopy calibration and image registration accuracy testing. Proc Med Imag Visualiz Imag Guided Proc Display 2002; 4681(1): 119-126.
    • (2002) Proc Med Imag Visualiz Imag Guided Proc Display , vol.4681 , Issue.1 , pp. 119-126
    • Bax, M.R.1    Khadem, R.2    Johnson, J.A.3
  • 9
    • 0023397578 scopus 로고
    • A versatile camera calibration technique for high-accuracy 3D machine vision metrology using off-the-shelf TV cameras and lenses
    • Tsai RY. A versatile camera calibration technique for high-accuracy 3D machine vision metrology using off-the-shelf TV cameras and lenses. IEEE Trans Robotics Automat 1987; RA-3(4): 323-344.
    • (1987) IEEE Trans Robotics Automat , vol.RA-3 , Issue.4 , pp. 323-344
    • Tsai, R.Y.1
  • 10
    • 23844512547 scopus 로고    scopus 로고
    • Real-time rendering of radially distorted virtual scenes for endoscopic image augmentation
    • Chen MS, Lapeer RJ, Rowland RS. Real-time rendering of radially distorted virtual scenes for endoscopic image augmentation. Stud Health Technol Informat 2005; 111: 87-89.
    • (2005) Stud Health Technol Informat , vol.111 , pp. 87-89
    • Chen, M.S.1    Lapeer, R.J.2    Rowland, R.S.3
  • 12
    • 84974686194 scopus 로고    scopus 로고
    • PC-based volume rendering for medical visualization and augmented reality based surgical navigation
    • Proceedings of MICCAI'02
    • Lapeer RJ, Rowland R, Chen MS. PC-based volume rendering for medical visualization and augmented reality based surgical navigation. Proceedings of (MICCAI'02), LNCS 2488, 2002; 596-603.
    • (2002) LNCS , vol.2488 , pp. 596-603
    • Lapeer, R.J.1    Rowland, R.2    Chen, M.S.3
  • 13
    • 0023381475 scopus 로고
    • Marching cubes: A high resolution 3D surface construction algorithm
    • Lorensen WE. Marching cubes: a high resolution 3D surface construction algorithm. ACM Comput Graphics 1987; 21(4): 163-169.
    • (1987) ACM Comput Graphics , vol.21 , Issue.4 , pp. 163-169
    • Lorensen, W.E.1
  • 14
    • 0030720201 scopus 로고    scopus 로고
    • Surface simplification using quadric error metrics
    • Garland M, Heckbert P. Surface simplification using quadric error metrics. In Proc SIGGRAPH 1997; 209-216.
    • (1997) Proc SIGGRAPH , pp. 209-216
    • Garland, M.1    Heckbert, P.2
  • 15
    • 0031927785 scopus 로고    scopus 로고
    • Vogele-Bale-Hohner mouthpiece: Registration device for frameless stereotactic surgery
    • Martin A, Bale RJ, Vogele M, et al. Vogele-Bale-Hohner mouthpiece: registration device for frameless stereotactic surgery. Radiology 1998; 208: 261-265.
    • (1998) Radiology , vol.208 , pp. 261-265
    • Martin, A.1    Bale, R.J.2    Vogele, M.3
  • 19
    • 0035509509 scopus 로고    scopus 로고
    • Using photoconsistency to register 2D optical images of the human face to a 3D surface model
    • Clarkson MJ, Rueckert D, Hill DL, Hawkes DJ. Using photoconsistency to register 2D optical images of the human face to a 3D surface model. IEEE Trans Pattern Anal Machine Intell 2001; 23(11): 1266-1280.
    • (2001) IEEE Trans Pattern Anal Machine Intell , vol.23 , Issue.11 , pp. 1266-1280
    • Clarkson, M.J.1    Rueckert, D.2    Hill, D.L.3    Hawkes, D.J.4
  • 20
    • 0032173355 scopus 로고    scopus 로고
    • Predicting error in rigid-body point-based registration
    • Fitzpatrick J, West J, Maurer C. Predicting error in rigid-body point-based registration. IEEE Trans Med Imag 1998; 17(5): 694-702.
    • (1998) IEEE Trans Med Imag , vol.17 , Issue.5 , pp. 694-702
    • Fitzpatrick, J.1    West, J.2    Maurer, C.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.