메뉴 건너뛰기




Volumn 208, Issue 1, 1998, Pages 261-265

Vogele-Bale-Hohner mouthpiece: Registration device for frameless stereotactic surgery

Author keywords

Computed tomography (CT), three dimensional; Computers, examination control; Magnetic resonance, MR, three dimensional; Stereotaxis

Indexed keywords

ACCURACY; ADULT; ARTICLE; COMPUTER ASSISTED DIAGNOSIS; CONTROLLED STUDY; FEMALE; HUMAN; MAJOR CLINICAL STUDY; MALE; MEASUREMENT; PRIORITY JOURNAL; STEREOTAXIC SURGERY; SURGICAL TECHNIQUE; TREATMENT OUTCOME;

EID: 0031927785     PISSN: 00338419     EISSN: None     Source Type: Journal    
DOI: 10.1148/radiology.208.1.9646822     Document Type: Article
Times cited : (47)

References (17)
  • 1
    • 0028695348 scopus 로고
    • Graphic-interactive cranial surgery
    • Guthrie BL. Graphic-interactive cranial surgery. Clin Neurosurg 1994; 41:489-516.
    • (1994) Clin Neurosurg , vol.41 , pp. 489-516
    • Guthrie, B.L.1
  • 5
    • 0027283759 scopus 로고
    • Frameless stereotaxic integration of CT imaging data: Accuracy and initial applications
    • Zinreich SJ, Tebo SA, Long DM, et al. Frameless stereotaxic integration of CT imaging data: accuracy and initial applications. Radiology 1993; 188:735-742.
    • (1993) Radiology , vol.188 , pp. 735-742
    • Zinreich, S.J.1    Tebo, S.A.2    Long, D.M.3
  • 6
    • 0030119410 scopus 로고    scopus 로고
    • Computerunterstützte chirurgie der nasennebenhöhlen mit einem optoelektronischen Ortungssystem
    • Hauser R, Westermann B, Reinhardt H, Probst R. Computerunterstützte chirurgie der nasennebenhöhlen mit einem optoelektronischen Ortungssystem. Laryngorhinootologie 1996; 75:199-207.
    • (1996) Laryngorhinootologie , vol.75 , pp. 199-207
    • Hauser, R.1    Westermann, B.2    Reinhardt, H.3    Probst, R.4
  • 7
    • 0001949356 scopus 로고
    • Beyond stereotaxy: Extreme levels of application accuracy are provided by implantable fiducial markers for interactive image-guided neurosurgery
    • Maciunas RJ, ed. Park Ridge, Ill: American Association of Neurological Surgeons
    • Maciunas RJ, Fitzpatrick JM, Galloway RL, Allen GS. Beyond stereotaxy: extreme levels of application accuracy are provided by implantable fiducial markers for interactive image-guided neurosurgery. In: Maciunas RJ, ed. Interactive image-guided neurosurgery: neurosurgical topics. Park Ridge, Ill: American Association of Neurological Surgeons, 1993; 259-270.
    • (1993) Interactive Image-guided Neurosurgery: Neurosurgical Topics , pp. 259-270
    • Maciunas, R.J.1    Fitzpatrick, J.M.2    Galloway, R.L.3    Allen, G.S.4
  • 8
    • 0030938762 scopus 로고    scopus 로고
    • Minimally invasive head holder to improve the performance of frameless stereotactic surgery
    • Bale RJ, Vogele M, Freysinger W, et al. Minimally invasive head holder to improve the performance of frameless stereotactic surgery. Laryngoscope 1997; 107:373-377.
    • (1997) Laryngoscope , vol.107 , pp. 373-377
    • Bale, R.J.1    Vogele, M.2    Freysinger, W.3
  • 12
    • 0030035977 scopus 로고    scopus 로고
    • A simple noninvasive stereotactic device for routine MR head examinations
    • Oshio K, Panych LP, Guttmann CRG. A simple noninvasive stereotactic device for routine MR head examinations. J Comput Assist Tomogr 1996; 20:588-591.
    • (1996) J Comput Assist Tomogr , vol.20 , pp. 588-591
    • Oshio, K.1    Panych, L.P.2    Guttmann, C.R.G.3
  • 13
    • 0023255639 scopus 로고
    • Noninvasive multipurpose Stereoadapter
    • Laitinen LV. Noninvasive multipurpose Stereoadapter. Neurol Res 1987; 9:137-141.
    • (1987) Neurol Res , vol.9 , pp. 137-141
    • Laitinen, L.V.1
  • 14
    • 0026592020 scopus 로고
    • A new model for non-invasive, reproducible fixation of a stereotaxic frame using an orthodontic resin plate
    • Carini S, Calcagno E, Tortori-Donati P, Andreussi L. A new model for non-invasive, reproducible fixation of a stereotaxic frame using an orthodontic resin plate (technical note). Acta Neurochir Wien 1992; 118:159-161.
    • (1992) Acta Neurochir Wien , vol.118 , pp. 159-161
    • Carini, S.1    Calcagno, E.2    Tortori-Donati, P.3    Andreussi, L.4
  • 15
    • 0028138452 scopus 로고
    • Minimally invasive stereotaxy: Clinical use of the Gill-Thomas-Cosman (GTC) repeat stereotactic localiser
    • Kitchen ND, Thomas DG. Minimally invasive stereotaxy: clinical use of the Gill-Thomas-Cosman (GTC) repeat stereotactic localiser. Minim Invasive Neurosurg 1994; 37:61-63.
    • (1994) Minim Invasive Neurosurg , vol.37 , pp. 61-63
    • Kitchen, N.D.1    Thomas, D.G.2
  • 17
    • 6844241934 scopus 로고    scopus 로고
    • VBH head holder to improve frameless stereotactic brachytherapy of cranial tumors
    • Bale RJ, Vogele M, Martin A, et al. VBH head holder to improve frameless stereotactic brachytherapy of cranial tumors. Comput Aided Surg 1997; 2:286-291.
    • (1997) Comput Aided Surg , vol.2 , pp. 286-291
    • Bale, R.J.1    Vogele, M.2    Martin, A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.