메뉴 건너뛰기




Volumn 36, Issue 3, 2008, Pages 152-156

Mechanical aspects of a multidirectional, angular stable osteosynthesis system and comparison with four conventional systems

Author keywords

angular stability; internal fixation; mandible fracture

Indexed keywords

ARTICLE; BONE DEFORMATION; BONE SCREW; CONTROLLED STUDY; FRACTURE FIXATION; HUMAN; INTERMETHOD COMPARISON; MANDIBLE FRACTURE; NONHUMAN; OSTEOSYNTHESIS; SURGICAL TECHNIQUE;

EID: 41149123798     PISSN: 10105182     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.jcms.2007.04.012     Document Type: Article
Times cited : (7)

References (20)
  • 1
    • 0017932324 scopus 로고
    • Mandibular osteosynthesis by miniature screwed plates via a buccal approach
    • Champy M., Lodde J.P., Schmitt R., Jaeger J.H., and Muster D. Mandibular osteosynthesis by miniature screwed plates via a buccal approach. J Maxillofac Surg 6 (1978) 14-21
    • (1978) J Maxillofac Surg , vol.6 , pp. 14-21
    • Champy, M.1    Lodde, J.P.2    Schmitt, R.3    Jaeger, J.H.4    Muster, D.5
  • 2
    • 0036266730 scopus 로고    scopus 로고
    • Use of a 2.0 mm locking plate/screw system for mandibular fracture surgery
    • Ellis E., and Graham J. Use of a 2.0 mm locking plate/screw system for mandibular fracture surgery. J Oral Maxillofac Surg 60 (2002) 642-645
    • (2002) J Oral Maxillofac Surg , vol.60 , pp. 642-645
    • Ellis, E.1    Graham, J.2
  • 3
    • 41149170852 scopus 로고    scopus 로고
    • Presentation and preliminary results of a newly developed, multidirectional and angular stable interlocking plate system in the treatment of facial fractures
    • Flinzberg S., Gbara A., and Schmelzle R. Presentation and preliminary results of a newly developed, multidirectional and angular stable interlocking plate system in the treatment of facial fractures. Eur J Trauma 2002 (2002) 52-57
    • (2002) Eur J Trauma , vol.2002 , pp. 52-57
    • Flinzberg, S.1    Gbara, A.2    Schmelzle, R.3
  • 4
    • 41149141531 scopus 로고    scopus 로고
    • Stabilisation of the bone fracture in the oral-maxillo-facial region with a new plate system
    • Gbara A., and Schmelzle R. Stabilisation of the bone fracture in the oral-maxillo-facial region with a new plate system. Mod Dent 1 (2000) 41-43
    • (2000) Mod Dent , vol.1 , pp. 41-43
    • Gbara, A.1    Schmelzle, R.2
  • 6
    • 0036843737 scopus 로고    scopus 로고
    • Does plate adaptation affect stability? A biomechanical comparison of locking and nonlocking plates
    • Haug R.H., Street C.C., and Goltz M. Does plate adaptation affect stability? A biomechanical comparison of locking and nonlocking plates. J Oral Maxillofac Surg 60 (2002) 1319-1326
    • (2002) J Oral Maxillofac Surg , vol.60 , pp. 1319-1326
    • Haug, R.H.1    Street, C.C.2    Goltz, M.3
  • 8
    • 0031252449 scopus 로고    scopus 로고
    • Distal femoral fixation: a biomechanical comparison of the standard condylar buttress plate, a locked buttress plate, and the 95-degree blade plate
    • Koval K.J., Hoehl J.J., Kummer F.J., and Simon J.A. Distal femoral fixation: a biomechanical comparison of the standard condylar buttress plate, a locked buttress plate, and the 95-degree blade plate. J Orthop Trauma 11 (1997) 521-524
    • (1997) J Orthop Trauma , vol.11 , pp. 521-524
    • Koval, K.J.1    Hoehl, J.J.2    Kummer, F.J.3    Simon, J.A.4
  • 10
    • 0004972987 scopus 로고    scopus 로고
    • The development of modern osteosynthesis
    • Luhr H.G. The development of modern osteosynthesis. Mund Kiefer Gesichtschir 1 Suppl. 4 (2000) S84-S90
    • (2000) Mund Kiefer Gesichtschir , vol.1 , Issue.SUPPL. 4
    • Luhr, H.G.1
  • 11
    • 0029863826 scopus 로고    scopus 로고
    • Results of treatment of fractures of the atrophic edentulous mandible by compression plating: a retrospective evaluation of 84 consecutive cases
    • Luhr H.G., Reidick T., and Merten H.A. Results of treatment of fractures of the atrophic edentulous mandible by compression plating: a retrospective evaluation of 84 consecutive cases. J Oral Maxillofac Surg 54 (1996) 250-254
    • (1996) J Oral Maxillofac Surg , vol.54 , pp. 250-254
    • Luhr, H.G.1    Reidick, T.2    Merten, H.A.3
  • 12
    • 0031469963 scopus 로고    scopus 로고
    • The evolution of modern plate osteosynthesis
    • Miclau T., and Martin R.E. The evolution of modern plate osteosynthesis. Injury 28 (1997) 3-6
    • (1997) Injury , vol.28 , pp. 3-6
    • Miclau, T.1    Martin, R.E.2
  • 13
    • 0029248968 scopus 로고
    • A mechanical comparison of the dynamic compression plate, limited contact-dynamic compression plate, and point contact fixateur
    • Miclau T., Remiger A., Tepic S., Lindsey R., and McIff T. A mechanical comparison of the dynamic compression plate, limited contact-dynamic compression plate, and point contact fixateur. J Orthop Trauma 9 (1995) 17-22
    • (1995) J Orthop Trauma , vol.9 , pp. 17-22
    • Miclau, T.1    Remiger, A.2    Tepic, S.3    Lindsey, R.4    McIff, T.5
  • 14
    • 0034185867 scopus 로고    scopus 로고
    • Mandibular fractures excluding condylar fractures
    • Niederdellmann H., and Marmulla R. Mandibular fractures excluding condylar fractures. Mund Kiefer Gesichtschir 1 Suppl. 4 (2000) S103-S109
    • (2000) Mund Kiefer Gesichtschir , vol.1 , Issue.SUPPL. 4
    • Niederdellmann, H.1    Marmulla, R.2
  • 15
    • 0021325939 scopus 로고
    • Use of the titanium-coated hollow screw and reconstruction plate system in bridging of lower jaw defects
    • Raveh J., Stich H., Sutter F., and Greiner R. Use of the titanium-coated hollow screw and reconstruction plate system in bridging of lower jaw defects. J Oral Maxillofac Surg 42 (1984) 281-294
    • (1984) J Oral Maxillofac Surg , vol.42 , pp. 281-294
    • Raveh, J.1    Stich, H.2    Sutter, F.3    Greiner, R.4
  • 17
    • 12244250402 scopus 로고    scopus 로고
    • Wirkprinzipien der winkelstabilen Platten-Schrauben-Verbindung bei Fixateur-interne-Osteosynthesen
    • Seide K., Morlock M., Schümann U., and Wolter D. Wirkprinzipien der winkelstabilen Platten-Schrauben-Verbindung bei Fixateur-interne-Osteosynthesen. Trauma Berufskrankh 1 (1999) 320-325
    • (1999) Trauma Berufskrankh , vol.1 , pp. 320-325
    • Seide, K.1    Morlock, M.2    Schümann, U.3    Wolter, D.4
  • 18
    • 0016998163 scopus 로고
    • Dynamic compression implant - principles, technique and results
    • Spiessl B. Dynamic compression implant - principles, technique and results. SSO Schweiz Monatsschr Zahnheilkd 86 (1976) 964-974
    • (1976) SSO Schweiz Monatsschr Zahnheilkd , vol.86 , pp. 964-974
    • Spiessl, B.1
  • 19
    • 0021307837 scopus 로고
    • Reposition and fixation of acromioclavicular luxation using a hooked plate
    • Wolter D., and Eggers C. Reposition and fixation of acromioclavicular luxation using a hooked plate. Hefte Unfallheilkd 170 (1984) 80-86
    • (1984) Hefte Unfallheilkd , vol.170 , pp. 80-86
    • Wolter, D.1    Eggers, C.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.