메뉴 건너뛰기




Volumn 29, Issue 3, 2008, Pages 341-348

Thermal screening of facial skin arterial hot spots using non-contact infrared radiometry

Author keywords

Body temperature; Fever; Temporal artery temperature; Tympanic temperature

Indexed keywords

DIAGNOSIS; THERMOMETERS;

EID: 41049093854     PISSN: 09673334     EISSN: 13616579     Source Type: Journal    
DOI: 10.1088/0967-3334/29/3/005     Document Type: Article
Times cited : (15)

References (16)
  • 2
    • 33645463671 scopus 로고    scopus 로고
    • Facial cold-induced vasodilation and skin temperature during exposure to cold wind
    • Brajkovic D and Ducharme M B 2006 Facial cold-induced vasodilation and skin temperature during exposure to cold wind Eur. J. Appl. Physiol. 96 711-21
    • (2006) Eur. J. Appl. Physiol. , vol.96 , Issue.6 , pp. 711-721
    • Brajkovic, D.1    Ducharme, M.B.2
  • 3
    • 34548744623 scopus 로고    scopus 로고
    • Comparison of infrared versus contact thermometry for measuring skin temperature during exercise in the heat
    • Buono M J, Jechort A, Marques R, Smith C and Welch J 2007 Comparison of infrared versus contact thermometry for measuring skin temperature during exercise in the heat Physiol. Meas. 28 855-9
    • (2007) Physiol. Meas. , vol.28 , Issue.8 , pp. 855-859
    • Buono, M.J.1    Jechort, A.2    Marques, R.3    Smith, C.4    Welch, J.5
  • 4
    • 22244462412 scopus 로고    scopus 로고
    • The patient: A novel source of error in clinical temperature measurement using infrared aural temperature
    • Heusch A I and McCarthy P W 2005 The patient: a novel source of error in clinical temperature measurement using infrared aural temperature J. Altern. Complement. Med. 11 473-6
    • (2005) J. Altern. Complement. Med. , vol.11 , Issue.3 , pp. 473-476
    • Heusch, A.I.1    McCarthy, P.W.2
  • 6
    • 10844258031 scopus 로고    scopus 로고
    • Limitations of forehead infrared body temperature detection for fever screening for severe acute respiratory syndrome
    • Liu C C, Chang R E and Chang W C 2004 Limitations of forehead infrared body temperature detection for fever screening for severe acute respiratory syndrome Infect. Control Hosp. Epidemiol. 25 1109-11
    • (2004) Infect. Control Hosp. Epidemiol. , vol.25 , Issue.12 , pp. 1109-1111
    • Liu, C.C.1    Chang, R.E.2    Chang, W.C.3
  • 7
    • 33746825062 scopus 로고    scopus 로고
    • The vagaries of ear temperature assessment
    • McCarthy P W and Heusch A I 2006 The vagaries of ear temperature assessment J. Med. Eng. Technol. 30 242-51
    • (2006) J. Med. Eng. Technol. , vol.30 , Issue.4 , pp. 242-251
    • McCarthy, P.W.1    Heusch, A.I.2
  • 8
    • 28844435990 scopus 로고    scopus 로고
    • Non-contact infrared thermometry temperature measurement for screening fever in children
    • Ng D K, Chung-Hong C, Lee R S and Lueng L C 2005 Non-contact infrared thermometry temperature measurement for screening fever in children Ann. Trop. Paediatr.: Int. Child Health 25 267-75
    • (2005) Ann. Trop. Paediatr.: Int. Child Health , vol.25 , Issue.4 , pp. 267-275
    • Ng, D.K.1    Chung-Hong, C.2    Lee, R.S.3    Lueng, L.C.4
  • 9
    • 4143056905 scopus 로고    scopus 로고
    • Analysis of IR thermal imager for mass blind fever screening
    • Ng E Y K, Kaw G J L and Chang W M 2004 Analysis of IR thermal imager for mass blind fever screening Microvas. Res. 68 104-9
    • (2004) Microvas. Res. , vol.68 , Issue.2 , pp. 104-109
    • Ng, E.Y.K.1    Kaw, G.J.L.2    Chang, W.M.3
  • 10
    • 34447513770 scopus 로고    scopus 로고
    • Channelling cold reception
    • Nilius B and Voets T 2007 Channelling cold reception Nature 448 147-8
    • (2007) Nature , vol.448 , Issue.7150 , pp. 147-148
    • Nilius, B.1    Voets, T.2
  • 11
    • 0037502292 scopus 로고    scopus 로고
    • Temporal artery temperature measurements in healthy infants, children and adolescents
    • Powell R S and Gerson L W 2003 Temporal artery temperature measurements in healthy infants, children and adolescents Clin. Pediatr. 42 433-7
    • (2003) Clin. Pediatr. , vol.42 , Issue.5 , pp. 433-437
    • Powell, R.S.1    Gerson, L.W.2
  • 12
    • 28544432730 scopus 로고    scopus 로고
    • Infrared ear thermometers-parameters influencing their reading and accuracy
    • Pušnik I and Drnovšek J 2005 Infrared ear thermometers-parameters influencing their reading and accuracy Physiol. Meas. 26 1075-84
    • (2005) Physiol. Meas. , vol.26 , Issue.6 , pp. 1075-1084
    • Pušnik, I.1    Drnovšek, J.2
  • 13
    • 3142583260 scopus 로고    scopus 로고
    • IR ear thermometers: What do they measure and how do they comply with the EU technical regulation?
    • Pušnik I, van der Ham E and Drnovšek J 2004 IR ear thermometers: what do they measure and how do they comply with the EU technical regulation? Physiol. Meas. 25 699-708
    • (2004) Physiol. Meas. , vol.25 , Issue.3 , pp. 699-708
    • Pušnik, I.1    Van Der Ham, E.2    Drnovšek, J.3
  • 14
    • 0346220372 scopus 로고    scopus 로고
    • New product review: Temporal artery thermometry
    • Sandlin D 2003 New product review: temporal artery thermometry J. Perianesth. Nurs. 18 419-21
    • (2003) J. Perianesth. Nurs. , vol.18 , Issue.6 , pp. 419-421
    • Sandlin, D.1
  • 15
    • 0015664595 scopus 로고
    • Spectral emissivity of skin and pericardium
    • Steketee J 1973 Spectral emissivity of skin and pericardium Phys. Med. Biol. 18 686-94
    • (1973) Phys. Med. Biol. , vol.18 , Issue.5 , pp. 686-694
    • Steketee, J.1
  • 16
    • 0036292261 scopus 로고    scopus 로고
    • Insufficiency of a new temporal-artery thermometer for adult and paediatric patients
    • Suleman M I, Doufas A G, Akça O, Durcharme M and Sessler D I 2002 Insufficiency of a new temporal-artery thermometer for adult and paediatric patients Anesth. Analg. 95 67-71
    • (2002) Anesth. Analg. , vol.95 , Issue.1 , pp. 67-71
    • Suleman, M.I.1    Doufas, A.G.2    Akça, O.3    Durcharme, M.4    Sessler, D.I.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.