Volumn 30, Issue 4, 2006, Pages 242-251

The vagaries of ear temperature assessment

Author keywords

Clinical; Humans; Infrared; Thermometry; Tympanic temperature measurement

Indexed keywords

CLINICAL; HUMANS; TYMPANIC MEMBRANE; TYMPANIC TEMPERATURE MEASUREMENT;

EID: 33746825062     PISSN: 03091902     EISSN: 1464522X     Source Type: Journal    
DOI: 10.1080/03091900600711415     Document Type: Review
Times cited : (34)

References (52)
  • 2
    • 0036228591 scopus 로고    scopus 로고
    • A brief history of the clinical thermometer
    • Pearce, J.M.S., 2002, A brief history of the clinical thermometer. Quarterly Journal of Medicine, 95, 251-252.
    • (2002) Quarterly Journal of Medicine , vol.95 , pp. 251-252
    • Pearce, J.M.S.1
  • 4
    • 33746844049 scopus 로고    scopus 로고
    • Traceability and calibration in temperature measurement: A clinical necessity
    • Simpson, R., Machin, G., et al., 2006, Traceability and calibration in temperature measurement: a clinical necessity. Journal of Medical Engineering & Technology, 30, 212-217.
    • (2006) Journal of Medical Engineering & Technology , vol.30 , pp. 212-217
    • Simpson, R.1    Machin, G.2
  • 5
    • 0015349508 scopus 로고
    • Taking adult temperature: Oral measurements
    • Nichols, G.A. and Kucha, D.H., 1972, Taking adult temperature: oral measurements. American Journal of Nursing, 72, 1091-1092.
    • (1972) American Journal of Nursing , vol.72 , pp. 1091-1092
    • Nichols, G.A.1    Kucha, D.H.2
  • 8
    • 0029871575 scopus 로고    scopus 로고
    • Effects of anatomic site, oral stimulation, and body position on estimates of body temperature
    • Rabinowitz, R.P., Cookson, S.T., Wasserman, S.S. and Mackowiak, P.A., 1996, Effects of anatomic site, oral stimulation, and body position on estimates of body temperature. Archives of Internal Medicine, 156, 777-780.
    • (1996) Archives of Internal Medicine , vol.156 , pp. 777-780
    • Rabinowitz, R.P.1    Cookson, S.T.2    Wasserman, S.S.3    Mackowiak, P.A.4
  • 9
    • 0033763404 scopus 로고    scopus 로고
    • Accuracy of digital tympanic, oral, axillary, and rectal thermometers compared with standard rectal mercury thermometers
    • Jensen, B.N., Jensen, F.S., Madsen, S.N. and Løssl, K., 2000, Accuracy of digital tympanic, oral, axillary, and rectal thermometers compared with standard rectal mercury thermometers. European Journal of Surgery, 166, 848-851.
    • (2000) European Journal of Surgery , vol.166 , pp. 848-851
    • Jensen, B.N.1    Jensen, F.S.2    Madsen, S.N.3    Løssl, K.4
  • 10
    • 0000639777 scopus 로고
    • Temperature in the external auditory meatus as an index of central temperature changes
    • Cooper, K.E., Cranston, W.I. and Snell, E.S., 1964, Temperature in the external auditory meatus as an index of central temperature changes. Journal of Applied Physiology, 19, 1032-1035.
    • (1964) Journal of Applied Physiology , vol.19 , pp. 1032-1035
    • Cooper, K.E.1    Cranston, W.I.2    Snell, E.S.3
  • 11
    • 0014125525 scopus 로고
    • Rectal temperatures, weight losses, and sweat rates in marathon running
    • Pugh, L.G.C.E., Corbett, J.L. and Johnson, R.H., 1967, Rectal temperatures, weight losses, and sweat rates in marathon running. Journal of Applied Physiology, 23, 347-352.
    • (1967) Journal of Applied Physiology , vol.23 , pp. 347-352
    • Pugh, L.G.C.E.1    Corbett, J.L.2    Johnson, R.H.3
  • 12
    • 0023787745 scopus 로고
    • Boston Marathoners get red carpet treatment in the medical tent
    • Bodishbaugh, R.G., 1988, Boston Marathoners get red carpet treatment in the medical tent. Physician & Sports Medicine, 16, 139-144.
    • (1988) Physician & Sports Medicine , vol.16 , pp. 139-144
    • Bodishbaugh, R.G.1
  • 13
    • 0029796389 scopus 로고    scopus 로고
    • Agreement between rectal and tympanic membrane temperatures in marathon runners
    • Roth, R.N., Verdile, V.P., Grollman, L.J. and Stone, D.A., 1996, Agreement between rectal and tympanic membrane temperatures in marathon runners. Annals of Emergency Medicine, 28, 414-417.
    • (1996) Annals of Emergency Medicine , vol.28 , pp. 414-417
    • Roth, R.N.1    Verdile, V.P.2    Grollman, L.J.3    Stone, D.A.4
  • 16
    • 0019834480 scopus 로고
    • Prediction of oesophageal temperatures from core temperatures measuring at other sites inman
    • Gibson, T.M., Redman, P.J. and Belyavin, A.J., 1981, Prediction of oesophageal temperatures from core temperatures measuring at other sites inman. Clinical Physics and Physiological Measurement, 2, 247-256.
    • (1981) Clinical Physics and Physiological Measurement , vol.2 , pp. 247-256
    • Gibson, T.M.1    Redman, P.J.2    Belyavin, A.J.3
  • 17
    • 0022541360 scopus 로고
    • Esophageal and tympanic temperature responses to changes in core blood temperature during hyperthermia
    • Shiraki, K., Konda, N. and Sagawa, S., 1986, Esophageal and tympanic temperature responses to changes in core blood temperature during hyperthermia. Journal of Applied Physiology, 61, 98-102.
    • (1986) Journal of Applied Physiology , vol.61 , pp. 98-102
    • Shiraki, K.1    Konda, N.2    Sagawa, S.3
  • 18
    • 0001651674 scopus 로고
    • Oral, rectal and oesophageal temperatures and some factors affecting them in man
    • Cranston, W.I., Gerbrandy, J. and Snell, E.S., 1954, Oral, rectal and oesophageal temperatures and some factors affecting them in man. Journal of Physiology, 126, 347-358.
    • (1954) Journal of Physiology , vol.126 , pp. 347-358
    • Cranston, W.I.1    Gerbrandy, J.2    Snell, E.S.3
  • 20
    • 33746840031 scopus 로고    scopus 로고
    • External and middle ear
    • S. Standring (Ed.) Edinburgh: Elsevier Churchill Livingstone
    • Berkovitz, B.K.B., 2005, External and middle ear. In: S. Standring (Ed.) Gray's Anatomy. The Anatomical Basis of Clinical Practice (Edinburgh: Elsevier Churchill Livingstone), pp. 649-661.
    • (2005) Gray's Anatomy. The Anatomical Basis of Clinical Practice , pp. 649-661
    • Berkovitz, B.K.B.1
  • 25
    • 0026476019 scopus 로고
    • Impact of operator technique and device on infrared emission detection tympanic thermometry
    • Terndrup, T.E. and Rajk, J., 1992, Impact of operator technique and device on infrared emission detection tympanic thermometry. Journal of Emergency Medicine, 10, 683-687.
    • (1992) Journal of Emergency Medicine , vol.10 , pp. 683-687
    • Terndrup, T.E.1    Rajk, J.2
  • 26
    • 0036579618 scopus 로고    scopus 로고
    • Temperament, tympanum, and temperature: Four provisional studies of the biobehavioural correlates of tympanic membrane temperature asymmetries
    • Boyce, W.T., Essex, M.J., Alkon, A., Smider, N.A., Pickrell, T. and Kagan, J., 2002, Temperament, tympanum, and temperature: four provisional studies of the biobehavioural correlates of tympanic membrane temperature asymmetries. Child Development, 73, 718-733.
    • (2002) Child Development , vol.73 , pp. 718-733
    • Boyce, W.T.1    Essex, M.J.2    Alkon, A.3    Smider, N.A.4    Pickrell, T.5    Kagan, J.6
  • 27
    • 1642502429 scopus 로고    scopus 로고
    • Cognition is cool: Can hemispheric activation be assessed by tympanic membrane thermometry?
    • Cherbuin, N. and Brinkman, C., 2004, Cognition is cool: Can hemispheric activation be assessed by tympanic membrane thermometry? Brain & Cognition, 54, 228-231.
    • (2004) Brain & Cognition , vol.54 , pp. 228-231
    • Cherbuin, N.1    Brinkman, C.2
  • 29
    • 0025758434 scopus 로고
    • Effect of otitis media on infrared tympanic thermometry
    • Kelly, B. and Alexander, D., 1991, Effect of otitis media on infrared tympanic thermometry. Clinical Pediatrics (Philadelphia), 30(Suppl. 4), 46-48; discussion 49.
    • (1991) Clinical Pediatrics (Philadelphia) , vol.30 , Issue.4 SUPPL. , pp. 46-48
    • Kelly, B.1    Alexander, D.2
  • 30
    • 0025756687 scopus 로고
    • The impact of technique and conditions of the tympanic membrane upon infrared tympanic thermometry
    • Pransky, S.M., 1991, The impact of technique and conditions of the tympanic membrane upon infrared tympanic thermometry. Clinical Pediatrics (Philadelphia), 30(Suppl. 4), 50-52; discussion 60.
    • (1991) Clinical Pediatrics (Philadelphia) , vol.30 , Issue.4 SUPPL. , pp. 50-52
    • Pransky, S.M.1
  • 31
    • 0032911407 scopus 로고    scopus 로고
    • Ear thermometry from the otologic viewpoint
    • Holtmann, S., 1999, Ear thermometry from the otologic viewpoint (in German). Laryngorhinootologie, 78, 9-11.
    • (1999) Laryngorhinootologie , vol.78 , pp. 9-11
    • Holtmann, S.1
  • 32
    • 0037762666 scopus 로고    scopus 로고
    • Clinical thermometry: Possible causes and potential solutions to electronic, digital thermometer inaccuracies
    • Latman, N.S., 2003, Clinical thermometry: possible causes and potential solutions to electronic, digital thermometer inaccuracies. Biomedical Instrumentation Technology, 37, 190-196.
    • (2003) Biomedical Instrumentation Technology , vol.37 , pp. 190-196
    • Latman, N.S.1
  • 34
    • 0028910914 scopus 로고
    • Fogging in infrared tympanic and ear thermometry
    • Kiesow, L.A. and Hurley, C.M., 1995, Fogging in infrared tympanic and ear thermometry. Annals of Internal Medicine, 122, 634-635.
    • (1995) Annals of Internal Medicine , vol.122 , pp. 634-635
    • Kiesow, L.A.1    Hurley, C.M.2
  • 35
    • 0026210396 scopus 로고
    • Tympanic thermometry: An index of hemispheric activity
    • Swift, A.B., 1991, Tympanic thermometry: an index of hemispheric activity. Perceptual and Motor Skills, 73, 275-293.
    • (1991) Perceptual and Motor Skills , vol.73 , pp. 275-293
    • Swift, A.B.1
  • 37
    • 33746854669 scopus 로고    scopus 로고
    • The effect of factors such as handedness, sex and age on body temperature measured by an infrared 'tympanic' thermometer
    • Heusch, A.I., Suresh, V. and McCarthy, P.W., 2006, The effect of factors such as handedness, sex and age on body temperature measured by an infrared 'tympanic' thermometer. Journal of Medical Engineering & Technology, 30, 235-241.
    • (2006) Journal of Medical Engineering & Technology , vol.30 , pp. 235-241
    • Heusch, A.I.1    Suresh, V.2    McCarthy, P.W.3
  • 38
    • 0041707202 scopus 로고    scopus 로고
    • Using an ear thermometer
    • Pullen Jr, R.L., 2003, Using an ear thermometer. Nursing, 33, 24.
    • (2003) Nursing , vol.33 , pp. 24
    • Pullen Jr., R.L.1
  • 39
    • 22244462412 scopus 로고    scopus 로고
    • The patient: A novel source of error in clinical temperature assessment using infrared aural thermometry
    • Heusch, A.I. and McCarthy, P.W., 2005, The patient: a novel source of error in clinical temperature assessment using infrared aural thermometry. Journal of Alternative and Complementary Medicine, 11, 473-476.
    • (2005) Journal of Alternative and Complementary Medicine , vol.11 , pp. 473-476
    • Heusch, A.I.1    McCarthy, P.W.2
  • 42
    • 0025872699 scopus 로고
    • The impact of moderate ambient temperature variance on the relationship between oral, rectal, and tympanic membrane temperatures
    • Zehner, W.J., Terndrup, T.E., 1991, The impact of moderate ambient temperature variance on the relationship between oral, rectal, and tympanic membrane temperatures. Clinical Pediatrics (Philadelphia), 30(Suppl. 4), 61-64; discussion 71-72.
    • (1991) Clinical Pediatrics (Philadelphia) , vol.30 , Issue.4 SUPPL. , pp. 61-64
    • Zehner, W.J.1    Terndrup, T.E.2
  • 43
    • 16544376991 scopus 로고    scopus 로고
    • Errors in body temperature assessment related to individual variation, measuring technique and equipment
    • Sund-Levander, M., Grodzinsky, E., Loyd, D. and Wahren, L.K., 2004, Errors in body temperature assessment related to individual variation, measuring technique and equipment. International Journal of Nursing Practice, 10, 216-223.
    • (2004) International Journal of Nursing Practice , vol.10 , pp. 216-223
    • Sund-Levander, M.1    Grodzinsky, E.2    Loyd, D.3    Wahren, L.K.4
  • 44
    • 33746859420 scopus 로고    scopus 로고
    • Current practice and knowledge of nurses regarding patient temperature measurement
    • Evans, J., 2006, Current practice and knowledge of nurses regarding patient temperature measurement. Journal of Medical Engineering & Technology, 30, 218-223.
    • (2006) Journal of Medical Engineering & Technology , vol.30 , pp. 218-223
    • Evans, J.1
  • 45
    • 14544273730 scopus 로고    scopus 로고
    • Accuracy of parents in measuring body temperature with a tympanic thermometer
    • Robinson, J.L., Jou, H. and Spady, D.W., 2005, Accuracy of parents in measuring body temperature with a tympanic thermometer. BMC Family Practice, 6(1), 3 Available online at: http://www. pubmedcentral.nih.gov/articlerender. fcgi?artid=545063 (accessed 1 April 2005).
    • (2005) BMC Family Practice , vol.6 , Issue.1 , pp. 3
    • Robinson, J.L.1    Jou, H.2    Spady, D.W.3
  • 46
    • 0037167250 scopus 로고    scopus 로고
    • Infrared ear thermometry compared with rectal thermometry in children: A systematic review
    • Craig, J.V., Lancaster, G.A., Taylor, S., Williamson, P.R. and Smyth, R.L., 2002, Infrared ear thermometry compared with rectal thermometry in children: a systematic review. The Lancet, 360, 603-609.
    • (2002) The Lancet , vol.360 , pp. 603-609
    • Craig, J.V.1    Lancaster, G.A.2    Taylor, S.3    Williamson, P.R.4    Smyth, R.L.5
  • 47
    • 33746819027 scopus 로고    scopus 로고
    • Apparent bilateral asymmetry in temperature of children of five and under using infrared ear thermometry
    • Suresh, V., McCarthy, P.W., McCabe, M., McCarthy, A. and Heusch, A.I., 2004, Apparent bilateral asymmetry in temperature of children of five and under using infrared ear thermometry. Journal of Physiology, 555P, PC109.
    • (2004) Journal of Physiology , vol.555 P
    • Suresh, V.1    McCarthy, P.W.2    McCabe, M.3    McCarthy, A.4    Heusch, A.I.5
  • 48
    • 3142583260 scopus 로고    scopus 로고
    • IR ear thermometers: What do they measure and how do they comply with the EU technical regulation?
    • Pusnik, I., van der Ham, E. and Drnovsek, J., 2004, IR ear thermometers: what do they measure and how do they comply with the EU technical regulation? Physiological Measurement, 25, 699-708.
    • (2004) Physiological Measurement , vol.25 , pp. 699-708
    • Pusnik, I.1    Van Der Ham, E.2    Drnovsek, J.3
  • 49
    • 0031819868 scopus 로고    scopus 로고
    • Unreliability of the infrared tympanic thermometer in clinical practice: A comparative study with oral mercury and oral electronic thermometers
    • Modell, J.G., Katholi, C.R., Kumaramangalam, S.M., Hudson, E.C. and Graham, D., 1998, Unreliability of the infrared tympanic thermometer in clinical practice: a comparative study with oral mercury and oral electronic thermometers. Southern Medical Journal, 91, 649-654.
    • (1998) Southern Medical Journal , vol.91 , pp. 649-654
    • Modell, J.G.1    Katholi, C.R.2    Kumaramangalam, S.M.3    Hudson, E.C.4    Graham, D.5
  • 51
    • 0036138027 scopus 로고    scopus 로고
    • The nerve supply of the human auricle
    • Peuker, E.T. and Filler, T.J., 2002, The nerve supply of the human auricle. Clinical Anatomy, 15, 35-37.
    • (2002) Clinical Anatomy , vol.15 , pp. 35-37
    • Peuker, E.T.1    Filler, T.J.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.