메뉴 건너뛰기




Volumn 5, Issue 4, 2008, Pages 526-535

Image integration using NavX fusion: Initial experience and validation

Author keywords

Atrial fibrillation; Computed tomography; Three dimensional image integration

Indexed keywords

ADULT; AGED; ANALYTICAL ERROR; ARTICLE; CATHETER ABLATION; COMPUTER PROGRAM; CONTROLLED STUDY; DIAGNOSTIC ACCURACY; DIAGNOSTIC VALUE; FEMALE; FLUOROSCOPY; GEOMETRY; HEART ATRIUM FIBRILLATION; HUMAN; IMAGE DISPLAY; IMAGE INTEGRATION; IMAGE PROCESSING; INTERMETHOD COMPARISON; MAJOR CLINICAL STUDY; MALE; PRIORITY JOURNAL; SPIRAL COMPUTER ASSISTED TOMOGRAPHY; STATISTICAL SIGNIFICANCE; THREE DIMENSIONAL IMAGING; TIME; TREATMENT DURATION;

EID: 40849133829     PISSN: 15475271     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.hrthm.2008.01.008     Document Type: Article
Times cited : (70)

References (20)
  • 1
    • 33750036653 scopus 로고    scopus 로고
    • Integration of cardiac CT/MR imaging with three-dimensional electroanatomical mapping to guide catheter manipulation in the left atrium: implications for catheter ablation of atrial fibrillation
    • Malchano Z.J., Neuzil P., Cury R.C., et al. Integration of cardiac CT/MR imaging with three-dimensional electroanatomical mapping to guide catheter manipulation in the left atrium: implications for catheter ablation of atrial fibrillation. J Cardiovasc Electrophysiol 17 (2006) 1221-1229
    • (2006) J Cardiovasc Electrophysiol , vol.17 , pp. 1221-1229
    • Malchano, Z.J.1    Neuzil, P.2    Cury, R.C.3
  • 2
    • 33747278349 scopus 로고    scopus 로고
    • Morphologic characteristics of the left atrial appendage, roof, and septum: implications for the ablation of atrial fibrillation
    • Wongcharoen W., Tsao H.M., Wu M.H., et al. Morphologic characteristics of the left atrial appendage, roof, and septum: implications for the ablation of atrial fibrillation. J Cardiovasc Electrophysiol 17 (2006) 951-956
    • (2006) J Cardiovasc Electrophysiol , vol.17 , pp. 951-956
    • Wongcharoen, W.1    Tsao, H.M.2    Wu, M.H.3
  • 3
    • 0037422529 scopus 로고    scopus 로고
    • Pulmonary vein ostium geometry: analysis by magnetic resonance angiography
    • Wittkampf F.H., Vonken E.J., Derksen R., et al. Pulmonary vein ostium geometry: analysis by magnetic resonance angiography. Circulation 107 (2003) 21-23
    • (2003) Circulation , vol.107 , pp. 21-23
    • Wittkampf, F.H.1    Vonken, E.J.2    Derksen, R.3
  • 4
    • 1942536466 scopus 로고    scopus 로고
    • Assessment of pulmonary vein anatomic variability by magnetic resonance imaging: implications for catheter ablation techniques for atrial fibrillation
    • Mansour M., Holmvang G., Sosnovik D., et al. Assessment of pulmonary vein anatomic variability by magnetic resonance imaging: implications for catheter ablation techniques for atrial fibrillation. J Cardiovasc Electrophysiol 15 (2004) 387-393
    • (2004) J Cardiovasc Electrophysiol , vol.15 , pp. 387-393
    • Mansour, M.1    Holmvang, G.2    Sosnovik, D.3
  • 5
    • 27744472289 scopus 로고    scopus 로고
    • The impact of respiration on left atrial and pulmonary venous anatomy: implications for image-guided intervention
    • Noseworthy P.A., Malchano Z.J., Ahmed J., et al. The impact of respiration on left atrial and pulmonary venous anatomy: implications for image-guided intervention. Heart Rhythm 2 (2005) 1173-1178
    • (2005) Heart Rhythm , vol.2 , pp. 1173-1178
    • Noseworthy, P.A.1    Malchano, Z.J.2    Ahmed, J.3
  • 7
    • 0037461101 scopus 로고    scopus 로고
    • Pulmonary vein anatomy in patients undergoing catheter ablation of atrial fibrillation: lessons learned by use of magnetic resonance imaging
    • Kato R., Lickfett L., Meininger G., et al. Pulmonary vein anatomy in patients undergoing catheter ablation of atrial fibrillation: lessons learned by use of magnetic resonance imaging. Circulation 107 (2003) 2004-2010
    • (2003) Circulation , vol.107 , pp. 2004-2010
    • Kato, R.1    Lickfett, L.2    Meininger, G.3
  • 8
    • 20844438328 scopus 로고    scopus 로고
    • Computed tomographic analysis of the anatomy of the left atrium and the esophagus: implications for left atrial catheter ablation
    • Lemola K., Sneider M., Desjardins B., et al. Computed tomographic analysis of the anatomy of the left atrium and the esophagus: implications for left atrial catheter ablation. Circulation 110 (2004) 3655-3660
    • (2004) Circulation , vol.110 , pp. 3655-3660
    • Lemola, K.1    Sneider, M.2    Desjardins, B.3
  • 9
    • 0036159331 scopus 로고    scopus 로고
    • Nonfluoroscopic magnetic electroanatomic mapping to facilitate focal pulmonary veins ablation for paroxysmal atrial fibrillation
    • Tse H.F., Lee K.L., Fan K., et al. Nonfluoroscopic magnetic electroanatomic mapping to facilitate focal pulmonary veins ablation for paroxysmal atrial fibrillation. Pacing Clin Electrophysiol 25 (2002) 57-61
    • (2002) Pacing Clin Electrophysiol , vol.25 , pp. 57-61
    • Tse, H.F.1    Lee, K.L.2    Fan, K.3
  • 10
    • 12844277465 scopus 로고    scopus 로고
    • A new nonfluoroscopic navigation system to guide pulmonary vein isolation
    • Tondo C., Mantica M., Russo G., et al. A new nonfluoroscopic navigation system to guide pulmonary vein isolation. Pacing Clin Electrophysiol 28 (2005) S102-S105
    • (2005) Pacing Clin Electrophysiol , vol.28
    • Tondo, C.1    Mantica, M.2    Russo, G.3
  • 11
    • 22944439488 scopus 로고    scopus 로고
    • Reduction of fluoroscopy exposure and procedure duration during ablation of atrial fibrillation using a novel anatomical navigation system
    • Rotter M., Takahashi Y., Sanders P., et al. Reduction of fluoroscopy exposure and procedure duration during ablation of atrial fibrillation using a novel anatomical navigation system. Eur Heart J 26 (2005) 1415-1421
    • (2005) Eur Heart J , vol.26 , pp. 1415-1421
    • Rotter, M.1    Takahashi, Y.2    Sanders, P.3
  • 12
    • 33645010220 scopus 로고    scopus 로고
    • Integrated electroanatomic mapping with three-dimensional computed tomographic images for real-time guided ablations
    • Dong J., Calkins H., Solomon S.B., et al. Integrated electroanatomic mapping with three-dimensional computed tomographic images for real-time guided ablations. Circulation 113 (2006) 186-194
    • (2006) Circulation , vol.113 , pp. 186-194
    • Dong, J.1    Calkins, H.2    Solomon, S.B.3
  • 13
    • 33748748786 scopus 로고    scopus 로고
    • The impact of CT image integration into an electroanatomic mapping system on clinical outcomes of catheter ablation of atrial fibrillation
    • Kistler P.M., Rajappan K., Jahngir M., et al. The impact of CT image integration into an electroanatomic mapping system on clinical outcomes of catheter ablation of atrial fibrillation. J Cardiovasc Electrophysiol 17 (2006) 1093-1101
    • (2006) J Cardiovasc Electrophysiol , vol.17 , pp. 1093-1101
    • Kistler, P.M.1    Rajappan, K.2    Jahngir, M.3
  • 14
    • 34848839833 scopus 로고    scopus 로고
    • Impact of integration of multislice computed tomography imaging into three-dimensional electroanatomic mapping on clinical outcomes, safety, and efficacy using radiofrequency ablation for atrial fibrillation
    • Martinek M., Nesser H.J., Aichinger J., et al. Impact of integration of multislice computed tomography imaging into three-dimensional electroanatomic mapping on clinical outcomes, safety, and efficacy using radiofrequency ablation for atrial fibrillation. Pacing Clin Electrophysiol 30 (2007) 1215-1223
    • (2007) Pacing Clin Electrophysiol , vol.30 , pp. 1215-1223
    • Martinek, M.1    Nesser, H.J.2    Aichinger, J.3
  • 15
    • 33645975865 scopus 로고    scopus 로고
    • Initial experience in the use of integrated electroanatomic mapping with three-dimensional MR/CT images to guide catheter ablation of atrial fibrillation
    • Dong J., Dickfeld T., Dalal D., et al. Initial experience in the use of integrated electroanatomic mapping with three-dimensional MR/CT images to guide catheter ablation of atrial fibrillation. J Cardiovasc Electrophysiol 17 (2006) 459-466
    • (2006) J Cardiovasc Electrophysiol , vol.17 , pp. 459-466
    • Dong, J.1    Dickfeld, T.2    Dalal, D.3
  • 16
    • 33645279547 scopus 로고    scopus 로고
    • Validation of three-dimensional cardiac image integration: use of integrated CT image into electroanatomic mapping system to perform catheter ablation of atrial fibrillation
    • Kistler P.M., Earley M.J., Harris S., et al. Validation of three-dimensional cardiac image integration: use of integrated CT image into electroanatomic mapping system to perform catheter ablation of atrial fibrillation. J Cardiovasc Electrophysiol 17 (2006) 341-348
    • (2006) J Cardiovasc Electrophysiol , vol.17 , pp. 341-348
    • Kistler, P.M.1    Earley, M.J.2    Harris, S.3
  • 17
    • 3142624488 scopus 로고    scopus 로고
    • The reconstruction, from a set of points, and analysis of the interior surface of the heart chamber
    • Kuklik P., Szumowski L., Zebrowski J.J., et al. The reconstruction, from a set of points, and analysis of the interior surface of the heart chamber. Physiol Meas 25 (2004) 617-627
    • (2004) Physiol Meas , vol.25 , pp. 617-627
    • Kuklik, P.1    Szumowski, L.2    Zebrowski, J.J.3
  • 18
    • 34548222143 scopus 로고    scopus 로고
    • Image integration for AF ablation: pearls and pitfalls
    • Kistler P.M., Schilling R.J., Rajappan K., et al. Image integration for AF ablation: pearls and pitfalls. Heart Rhythm 4 (2007) 1216-1221
    • (2007) Heart Rhythm , vol.4 , pp. 1216-1221
    • Kistler, P.M.1    Schilling, R.J.2    Rajappan, K.3
  • 19
    • 34247338104 scopus 로고    scopus 로고
    • On the accuracy of CartoMerge for guiding posterior left atrial ablation in man
    • Zhong H., Lacomis J.M., and Schwartzman D. On the accuracy of CartoMerge for guiding posterior left atrial ablation in man. Heart Rhythm 4 (2007) 595-602
    • (2007) Heart Rhythm , vol.4 , pp. 595-602
    • Zhong, H.1    Lacomis, J.M.2    Schwartzman, D.3
  • 20
    • 33846990846 scopus 로고    scopus 로고
    • Intracardiac echo-guided image integration: optimizing strategies for registration
    • Fahmy T.S., Mlcochova H., Wazni O.M., et al. Intracardiac echo-guided image integration: optimizing strategies for registration. J Cardiovasc Electrophysiol 18 (2007) 276-282
    • (2007) J Cardiovasc Electrophysiol , vol.18 , pp. 276-282
    • Fahmy, T.S.1    Mlcochova, H.2    Wazni, O.M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.