메뉴 건너뛰기




Volumn 40, Issue 3, 2008, Pages 1130-1143

A novel technique for modeling susceptibility-based contrast mechanisms for arbitrary microvascular geometries: The finite perturber method

Author keywords

Arbitrary geometry; BOLD fMRI; Contrast; Dynamic susceptibility; Microvasculature; Tumor angiogenesis

Indexed keywords

ANGIOGENESIS; ARTICLE; BRAIN TUMOR; COMPUTER MODEL; FINITE PERTURBER METHOD; GEOMETRY; MICROVASCULATURE; MORPHOLOGY; NUCLEAR MAGNETIC RESONANCE IMAGING; PRIORITY JOURNAL; SIMULATION; TUMOR VASCULARIZATION;

EID: 40749094526     PISSN: 10538119     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.neuroimage.2008.01.022     Document Type: Article
Times cited : (74)

References (33)
  • 2
    • 0029313435 scopus 로고
    • * and R2 changes: simulations using a deterministic diffusion model
    • * and R2 changes: simulations using a deterministic diffusion model. Int. J. Imaging Syst. Tech. 6 (1995) 133-152
    • (1995) Int. J. Imaging Syst. Tech. , vol.6 , pp. 133-152
    • Bandettini, P.A.1    Wong, E.C.2
  • 5
    • 0009569549 scopus 로고
    • MR contrast due to microscopically heterogeneous magnetic susceptibility: cylindrical geometry
    • Society of Magnetic Resonance in Medicine, New York
    • Boxerman J.L., W.R., Hoppel B.E., and Rosen B.R. MR contrast due to microscopically heterogeneous magnetic susceptibility: cylindrical geometry. 1st Annual Meeting (1993), Society of Magnetic Resonance in Medicine, New York 389
    • (1993) 1st Annual Meeting , pp. 389
    • Boxerman, J.L.1    Hoppel, B.E.2    Rosen, B.R.3
  • 7
    • 0029096047 scopus 로고
    • MR contrast due to intravascular magnetic susceptibility perturbations
    • Boxerman J.L., Hamberg L.M., Rosen B.R., and Weisskoff R.M. MR contrast due to intravascular magnetic susceptibility perturbations. Mag. Reson. Med. 34 (1995) 555-566
    • (1995) Mag. Reson. Med. , vol.34 , pp. 555-566
    • Boxerman, J.L.1    Hamberg, L.M.2    Rosen, B.R.3    Weisskoff, R.M.4
  • 9
    • 0019351063 scopus 로고
    • The vasculature of experimental brain tumors - Part 2: a quantitative assessment of morphological abnormalities
    • Deane B.R., and Lantos P.L. The vasculature of experimental brain tumors - Part 2: a quantitative assessment of morphological abnormalities. J. Neurological Science 49 (1981) 67-77
    • (1981) J. Neurological Science , vol.49 , pp. 67-77
    • Deane, B.R.1    Lantos, P.L.2
  • 10
    • 0034045183 scopus 로고    scopus 로고
    • Utility of simultaneously acquired gradient-echo and spin-echo cerebral blood volume and morphology maps in brain tumor patients
    • Donahue K.M., Krouwer H.G., Rand S.D., Pathak A.P., Marszalkowski C.S., Censky S.C., and Prost R.W. Utility of simultaneously acquired gradient-echo and spin-echo cerebral blood volume and morphology maps in brain tumor patients. Magn. Reson. Med. 43 (2000) 845-853
    • (2000) Magn. Reson. Med. , vol.43 , pp. 845-853
    • Donahue, K.M.1    Krouwer, H.G.2    Rand, S.D.3    Pathak, A.P.4    Marszalkowski, C.S.5    Censky, S.C.6    Prost, R.W.7
  • 11
    • 0026081190 scopus 로고
    • MR contrast due to microscopically heterogeneous magnetic susceptibility: numerical simulations and applications to cerebral physiology
    • Fisel C.R., Ackerman J.L., Buxton R.B., Garrido L., Belliveau J.W., Rosen R.B., and Brady T.J. MR contrast due to microscopically heterogeneous magnetic susceptibility: numerical simulations and applications to cerebral physiology. Mag. Reson. Med. 17 (1991) 336-347
    • (1991) Mag. Reson. Med. , vol.17 , pp. 336-347
    • Fisel, C.R.1    Ackerman, J.L.2    Buxton, R.B.3    Garrido, L.4    Belliveau, J.W.5    Rosen, R.B.6    Brady, T.J.7
  • 13
    • 0027374735 scopus 로고
    • Imaging system for three-dimensional mapping of cerebrocortical capillary networks in vivo
    • Hudetz A.G., Green A.S., Fehrer G., Kneuse D.K., and Cowley A.W. Imaging system for three-dimensional mapping of cerebrocortical capillary networks in vivo. Microvascular Res. 46 (1993) 293-309
    • (1993) Microvascular Res. , vol.46 , pp. 293-309
    • Hudetz, A.G.1    Green, A.S.2    Fehrer, G.3    Kneuse, D.K.4    Cowley, A.W.5
  • 14
    • 4243079824 scopus 로고    scopus 로고
    • Perturbation method for magnetic field calculations of nonconductive objects
    • Jenkinson M., Wilson J.L., and Jezzard P. Perturbation method for magnetic field calculations of nonconductive objects. Magn. Reson. Med. 52 (2004) 471-477
    • (2004) Magn. Reson. Med. , vol.52 , pp. 471-477
    • Jenkinson, M.1    Wilson, J.L.2    Jezzard, P.3
  • 15
    • 0028158554 scopus 로고
    • Intravascular susceptibility contrast mechanisms in tissues
    • Kennan R.P. Intravascular susceptibility contrast mechanisms in tissues. Mag. Reson. Med. 31 (1994) 9-21
    • (1994) Mag. Reson. Med. , vol.31 , pp. 9-21
    • Kennan, R.P.1
  • 16
    • 0035180810 scopus 로고    scopus 로고
    • On the theoretical basis of perfusion measurements by dynamic susceptibility contrast MRI
    • Kiselev V.G. On the theoretical basis of perfusion measurements by dynamic susceptibility contrast MRI. Mag. Reson. Med. 46 (2001) 1113-1122
    • (2001) Mag. Reson. Med. , vol.46 , pp. 1113-1122
    • Kiselev, V.G.1
  • 17
    • 28444467350 scopus 로고    scopus 로고
    • Transverse relaxation effect of MRI contrast agents: a crucial issue for quantitative measurements of cerebral perfusion
    • Kiselev V.G. Transverse relaxation effect of MRI contrast agents: a crucial issue for quantitative measurements of cerebral perfusion. J. Magn. Reson. Imaging 22 (2005) 693-696
    • (2005) J. Magn. Reson. Imaging , vol.22 , pp. 693-696
    • Kiselev, V.G.1
  • 18
    • 33846873463 scopus 로고    scopus 로고
    • Rapid calculations of susceptibility-induced magnetostatic field perturbations for in vivo magnetic resonance
    • Koch K.M., Papademetris X., Rothman D.L., and de Graaf R.A. Rapid calculations of susceptibility-induced magnetostatic field perturbations for in vivo magnetic resonance. Phys. Med. Biol. 51 (2006) 6381-6402
    • (2006) Phys. Med. Biol. , vol.51 , pp. 6381-6402
    • Koch, K.M.1    Papademetris, X.2    Rothman, D.L.3    de Graaf, R.A.4
  • 20
    • 2342503263 scopus 로고    scopus 로고
    • Quantifying arbitrary magnetic susceptibility distributions with MR
    • Li L., and Leigh J.S. Quantifying arbitrary magnetic susceptibility distributions with MR. Magn. Reson. Med. 51 (2004) 1077-1082
    • (2004) Magn. Reson. Med. , vol.51 , pp. 1077-1082
    • Li, L.1    Leigh, J.S.2
  • 21
  • 22
    • 0025096481 scopus 로고
    • MRI of blood vessels at high fields: in vivo and in vitro measurements and image simulation
    • Ogawa S. MRI of blood vessels at high fields: in vivo and in vitro measurements and image simulation. Mag. Reson. Med. 16 (1990) 9-18
    • (1990) Mag. Reson. Med. , vol.16 , pp. 9-18
    • Ogawa, S.1
  • 23
    • 0034799187 scopus 로고    scopus 로고
    • MR-derived cerebral blood volume maps: issues regarding histological validation and assessment of tumor angiogenesis
    • Pathak A., Schmainda K., Ward B., Linderman J., Rebro K.J., and Greene A.S. MR-derived cerebral blood volume maps: issues regarding histological validation and assessment of tumor angiogenesis. Magn. Reson. Med. 46 (2001) 735-747
    • (2001) Magn. Reson. Med. , vol.46 , pp. 735-747
    • Pathak, A.1    Schmainda, K.2    Ward, B.3    Linderman, J.4    Rebro, K.J.5    Greene, A.S.6
  • 26
    • 0025180569 scopus 로고
    • Perfusion imaging with NMR contrast agents
    • Rosen B.R. Perfusion imaging with NMR contrast agents. Mag. Reson. Med. 14 (1990) 249-265
    • (1990) Mag. Reson. Med. , vol.14 , pp. 249-265
    • Rosen, B.R.1
  • 27
    • 0026343822 scopus 로고
    • Susceptibility contrast imaging of cerebral blood volume: human experience
    • Rosen B.R. Susceptibility contrast imaging of cerebral blood volume: human experience. Mag. Reson. Med. 22 (1991) 293-299
    • (1991) Mag. Reson. Med. , vol.22 , pp. 293-299
    • Rosen, B.R.1
  • 30
    • 0026520830 scopus 로고
    • MRI susceptometry: image-based measurement of absolute susceptibility of MR contrast agents and human blood
    • Weisskoff R.M., and Kiihne S. MRI susceptometry: image-based measurement of absolute susceptibility of MR contrast agents and human blood. Magn. Reson. Med. 24 (1992) 375-383
    • (1992) Magn. Reson. Med. , vol.24 , pp. 375-383
    • Weisskoff, R.M.1    Kiihne, S.2
  • 31
    • 0028321471 scopus 로고
    • Microscopic susceptibility variation and transverse relaxation: theory and experiment
    • Weisskoff R.M., Zuo C.S., Boxerman J.L., and Rosen B.R. Microscopic susceptibility variation and transverse relaxation: theory and experiment. Mag. Reson. Med. 31 (1994) 601-610
    • (1994) Mag. Reson. Med. , vol.31 , pp. 601-610
    • Weisskoff, R.M.1    Zuo, C.S.2    Boxerman, J.L.3    Rosen, B.R.4
  • 32
    • 0027973923 scopus 로고
    • Theory of NMR signal behavior in magnetically inhomogeneous tissues: the static dephasing regime
    • Yablonskiy D.A. Theory of NMR signal behavior in magnetically inhomogeneous tissues: the static dephasing regime. Mag. Reson. Med. 32 (1994) 749-763
    • (1994) Mag. Reson. Med. , vol.32 , pp. 749-763
    • Yablonskiy, D.A.1
  • 33
    • 0000606319 scopus 로고
    • Theoretical basis of indicator-dilution methods for measuring flow and volume
    • March
    • Zierler K.L. Theoretical basis of indicator-dilution methods for measuring flow and volume. Circulation Res. X (1962) 393-407 March
    • (1962) Circulation Res. X , pp. 393-407
    • Zierler, K.L.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.