메뉴 건너뛰기




Volumn 32, Issue 2, 2008, Pages 101-106

Adaptive motion artifacts reduction using 3-axis accelerometer in E-textile ECG measurement system

Author keywords

Accelerometer; Adaptive filter; E textile; ECG; Motion artifacts

Indexed keywords

ACCELEROMETER; ARTICLE; ELECTROCARDIOGRAM; HEALTH CARE SYSTEM; MOTION ANALYSIS SYSTEM;

EID: 40549111353     PISSN: 01485598     EISSN: None     Source Type: Journal    
DOI: 10.1007/s10916-007-9112-x     Document Type: Article
Times cited : (53)

References (10)
  • 2
    • 11144352779 scopus 로고    scopus 로고
    • A new portable device for ambulatory monitoring of human posture and walking velocity using miniature accelerometers and gyroscope
    • San Francisco, CA, USA, 1-5 Sept.
    • Tanaka, S., Motoi, K., Nogawa, M., and Yamakoshi, K., A new portable device for ambulatory monitoring of human posture and walking velocity using miniature accelerometers and gyroscope. IEEE EMBS Proc., 26th Annual International Conference, San Francisco, CA, USA, 3:2283-2286, 2004, 1-5 Sept.
    • (2004) IEEE EMBS Proc., 26th Annual International Conference , vol.3 , pp. 2283-2286
    • Tanaka, S.1    Motoi, K.2    Nogawa, M.3    Yamakoshi, K.4
  • 6
    • 0031106763 scopus 로고    scopus 로고
    • A real-time microprocessor QRS detector system with a 1-ms timing accuracy for the measurement of ambulatory HRV
    • 3. Mar
    • Ruha, A., Sallinen, S., and Nissila, S., A real-time microprocessor QRS detector system with a 1-ms timing accuracy for the measurement of ambulatory HRV. IEEE Trans. Biomed. Eng 44:3159-167, 1997, Mar.
    • (1997) IEEE Trans. Biomed. Eng , vol.44 , pp. 159-167
    • Ruha, A.1    Sallinen, S.2    Nissila, S.3
  • 7
    • 34047136656 scopus 로고    scopus 로고
    • Reduction of skin stretch induced motion artifacts in electrocardiogram monitoring using adaptive filtering
    • New York City, USA, 30 Aug. - 3 Sept.
    • Liu, Y., and Pecht, M. G., Reduction of skin stretch induced motion artifacts in electrocardiogram monitoring using adaptive filtering. IEEE EMBS Proc., 28th Annual International Conference. New York City, USA, 6045-6048, 2006, 30 Aug. - 3 Sept.
    • (2006) IEEE EMBS Proc., 28th Annual International Conference , pp. 6045-6048
    • Liu, Y.1    Pecht, M.G.2
  • 8
    • 34249737388 scopus 로고    scopus 로고
    • Adaptive motion artifacts reduction algorithm for ECG signal in textile wearable sensor
    • 10
    • Yoon, S. W., Shin, H. S., Min, S. D., and Lee, M., Adaptive motion artifacts reduction algorithm for ECG signal in textile wearable sensor. IEICE Electron. Express 4:10312-318, 2007.
    • (2007) IEICE Electron. Express , vol.4 , pp. 312-318
    • Yoon, S.W.1    Shin, H.S.2    Min, S.D.3    Lee, M.4
  • 10
    • 0003807773 scopus 로고    scopus 로고
    • 3 Upper Saddle River, NJ Prentice-Hall, Inc.
    • Haykin, S., Adaptive Filter Theory, Prentice-Hall, Inc.: Third Edition, Upper Saddle River, NJ, 1996.
    • (1996) Adaptive Filter Theory
    • Haykin, S.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.