Volumn 4, Issue 10, 2007, Pages 312-318

Adaptive motion artifacts reduction algorithm for ECG signal in textile wearable sensor

Author keywords

Adaptive filtering; ECG; Motion artifacts; Wearable sensor

Indexed keywords


EID: 34249737388     PISSN: None     EISSN: 13492543     Source Type: Journal    
DOI: 10.1587/elex.4.312     Document Type: Article
Times cited : (8)

References (8)
  • 2
    • 11144352779 scopus 로고    scopus 로고
    • A New Portable Device for Ambulatory Monitoring of Human Posture and Walking Velocity Using Miniature Accelerometers and Gyroscope
    • San Francisco, CA, USA, 1-5 Sept
    • S. Tanaka, K. Motoi, M. Nogawa, and K. Yamakoshi, "A New Portable Device for Ambulatory Monitoring of Human Posture and Walking Velocity Using Miniature Accelerometers and Gyroscope," IEEE EMBS Proc., 26th Annual Int. Conf., San Francisco, CA., USA, vol. 3. pp. 2283-2286, 1-5 Sept., 2004.
    • (2004) IEEE EMBS Proc., 26th Annual Int. Conf , vol.3 , pp. 2283-2286
    • Tanaka, S.1    Motoi, K.2    Nogawa, M.3    Yamakoshi, K.4
  • 3
    • 33846911553 scopus 로고    scopus 로고
    • Textile Sensing Interfaces for Cardiopulmonary Signs Monitoring
    • Shanghai, China, pp, 1-4 Sept
    • G. Loriga, N. Taccini, D. De Rossi, and R. Paradiso, "Textile Sensing Interfaces for Cardiopulmonary Signs Monitoring," IEEE EMBS Proc., 27th Annual Int. Conf., Shanghai, China, pp. 7349-7352, 1-4 Sept., 2005.
    • (2005) IEEE EMBS Proc., 27th Annual Int. Conf , pp. 7349-7352
    • Loriga, G.1    Taccini, N.2    De Rossi, D.3    Paradiso, R.4
  • 4
    • 0036911308 scopus 로고    scopus 로고
    • Adaptive Reduction of Motion Artifacts in the Electrocardiogram
    • Houston, Tx, USA, 23-26 Oct
    • D. A. Tong, K. A. Bartels, and K. S. Honeyager, "Adaptive Reduction of Motion Artifacts in the Electrocardiogram," IEEE EMBS/BMES Proc., 2nd Joint EMBS/BMES Conf., Houston, Tx, USA, vol. 2, pp. 1403-1404, 23-26 Oct. 2002.
    • (2002) IEEE EMBS/BMES Proc., 2nd Joint EMBS/BMES Conf , vol.2 , pp. 1403-1404
    • Tong, D.A.1    Bartels, K.A.2    Honeyager, K.S.3
  • 6
    • 0031106763 scopus 로고    scopus 로고
    • A Real-Time Microprocessor QRS Detector System with a 1-ms Timing Accuracy for the Measurement of Ambulatory HRV
    • March
    • A. Kuba, S. Sallinen, and S. Nissila, "A Real-Time Microprocessor QRS Detector System with a 1-ms Timing Accuracy for the Measurement of Ambulatory HRV," IEEE Trans. Biorned. Eng., vol. 44, no. 3, pp. 159-167, March 1997.
    • (1997) IEEE Trans. Biorned. Eng , vol.44 , Issue.3 , pp. 159-167
    • Kuba, A.1    Sallinen, S.2    Nissila, S.3
  • 7
    • 34047136656 scopus 로고    scopus 로고
    • Reduction of Skin Stretch Induced Motion Artifacts in Electrocardiogram Monitoring Using Adaptive Filtering
    • New York City, USA, pp, 30 Aug, 3 Sept
    • Y. Liu and M. G. Pecht, "Reduction of Skin Stretch Induced Motion Artifacts in Electrocardiogram Monitoring Using Adaptive Filtering," IEEE EMBS Proc., 28th Annual Int. Conf., New York City, USA, pp. 6045-6048, 30 Aug. -3 Sept., 2006.
    • (2006) IEEE EMBS Proc., 28th Annual Int. Conf , pp. 6045-6048
    • Liu, Y.1    Pecht, M.G.2