Volumn 17, Issue 1, 2008, Pages 139-146

A flow rate independent cell concentration measurement chip using electrical cell counters across a fixed control volume

Author keywords

Biomedical equipment; Biomedical impedance imaging; Biomedical laboratories

Indexed keywords

CYTOLOGY; FLOW CONTROL; FLOW MEASUREMENT; FLOW RATE; MEDICAL IMAGING;

EID: 40449135748     PISSN: 10577157     EISSN: None     Source Type: Journal    
DOI: 10.1109/JMEMS.2007.906766     Document Type: Article
Times cited : (12)

References (17)
  • 1
    • 0036200750 scopus 로고    scopus 로고
    • MEMS-based sample preparation for molecular diagnostics
    • Jan
    • Y. Huang, E. L. Mather, J. L. Bell, and M. Madou, "MEMS-based sample preparation for molecular diagnostics," Anal. Bioanal. Chem., vol. 372, no. 1, pp. 49-65, Jan. 2002.
    • (2002) Anal. Bioanal. Chem , vol.372 , Issue.1 , pp. 49-65
    • Huang, Y.1    Mather, E.L.2    Bell, J.L.3    Madou, M.4
  • 3
    • 0002222889 scopus 로고    scopus 로고
    • Trends in miniaturized total analysis systems for point-of-care testing in clinical chemistry
    • A. J. Tudos, G. A. J. Besselink, and R. B. M. Schasfoort, "Trends in miniaturized total analysis systems for point-of-care testing in clinical chemistry," Lab Chip, vol. 1, pp. 83-95, 2001.
    • (2001) Lab Chip , vol.1 , pp. 83-95
    • Tudos, A.J.1    Besselink, G.A.J.2    Schasfoort, R.B.M.3
  • 4
    • 0037902179 scopus 로고    scopus 로고
    • Microfluidic devices for cellomics: A review
    • Jul
    • H. Andersson and A. V. D. Berg, "Microfluidic devices for cellomics: A review," Sens. Actuators B, Chem., vol. 92, no. 3, pp. 315-325, Jul. 2003.
    • (2003) Sens. Actuators B, Chem , vol.92 , Issue.3 , pp. 315-325
    • Andersson, H.1    Berg, A.V.D.2
  • 6
    • 0033138334 scopus 로고    scopus 로고
    • Design and fabrication of a micromachined Coulter counter
    • Jun
    • M. Koch, A. G. R. Evans, and A. Brunnschweiler, "Design and fabrication of a micromachined Coulter counter," J. Micromech. Microeng., vol. 9, no. 2, pp. 159-161, Jun. 1999.
    • (1999) J. Micromech. Microeng , vol.9 , Issue.2 , pp. 159-161
    • Koch, M.1    Evans, A.G.R.2    Brunnschweiler, A.3
  • 7
    • 0141989814 scopus 로고    scopus 로고
    • Micromachined impedance spectroscopy flow cytometer for cell analysis and particle sizing
    • S. Gawad, L. Schild, and P. Renaud, "Micromachined impedance spectroscopy flow cytometer for cell analysis and particle sizing," Lab Chip, vol. 1, no. 1, pp. 76-82, 2001.
    • (2001) Lab Chip , vol.1 , Issue.1 , pp. 76-82
    • Gawad, S.1    Schild, L.2    Renaud, P.3
  • 8
    • 0038353914 scopus 로고    scopus 로고
    • Micromachined flow cytometers with embedded etched optic fibers for optical detection
    • May
    • C.-H. Lin and G.-B. Lee, "Micromachined flow cytometers with embedded etched optic fibers for optical detection," J. Micromech. Microeng. vol. 13, no. 3, pp. 447-453, May 2003.
    • (2003) J. Micromech. Microeng , vol.13 , Issue.3 , pp. 447-453
    • Lin, C.-H.1    Lee, G.-B.2
  • 9
    • 0033214875 scopus 로고    scopus 로고
    • Microchip flow cytometry using electrokinetic focusing
    • D. P. Schrum, C. T. Culbertson, S. C. Jacobson, and J. M. Ramsey, "Microchip flow cytometry using electrokinetic focusing," Anal. Chem., vol. 71, no. 19, pp. 4173-4177, 1999.
    • (1999) Anal. Chem , vol.71 , Issue.19 , pp. 4173-4177
    • Schrum, D.P.1    Culbertson, C.T.2    Jacobson, S.C.3    Ramsey, J.M.4
  • 10
    • 34247605172 scopus 로고    scopus 로고
    • Fabrication of micro cell counter integrated with oxygen micropump
    • Squaw Valley, CA
    • S. U. Son, Y. H. Choi, and S. S. Lee, "Fabrication of micro cell counter integrated with oxygen micropump," in Proc. Micro Total Anal. Syst., Squaw Valley, CA, 2003, pp. 179-182.
    • (2003) Proc. Micro Total Anal. Syst , pp. 179-182
    • Son, S.U.1    Choi, Y.H.2    Lee, S.S.3
  • 11
    • 40449140117 scopus 로고    scopus 로고
    • Micro flow cytometers using electrokinetic forces with integrated optical fibers for on-line cell/particle counting and sorting
    • Squaw Valley, CA
    • G.-B. Lee, L.-M. Fu, R.-J. Yang, and Y.-J. Pan, "Micro flow cytometers using electrokinetic forces with integrated optical fibers for on-line cell/particle counting and sorting," in Proc. Micro Total Anal. Syst., Squaw Valley, CA, 2003, pp. 45-48.
    • (2003) Proc. Micro Total Anal. Syst , pp. 45-48
    • Lee, G.-B.1    Fu, L.-M.2    Yang, R.-J.3    Pan, Y.-J.4
  • 14
    • 40449130593 scopus 로고    scopus 로고
    • Beckman Coulter, Inc, USA, Available
    • Beckman Coulter, Inc, USA, Z Series Coulter Counter. [Online]. Available: Www.beckmancoulter.com/literature/Bioresearch/BR-9723A.pdf
    • Z Series Coulter Counter. [Online]
  • 15
    • 0031852339 scopus 로고    scopus 로고
    • Characterization of erythrocyte shapes and sizes by NMR diffusion-diffraction of water
    • May
    • A. M. Torres, R. J. Michniweicz, B. E. Chapman, G. A. R. Young, and P. W. Kuchel, "Characterization of erythrocyte shapes and sizes by NMR diffusion-diffraction of water," Magn. Reson. Imaging, vol. 16, no. 4, pp. 423-434, May 1998.
    • (1998) Magn. Reson. Imaging , vol.16 , Issue.4 , pp. 423-434
    • Torres, A.M.1    Michniweicz, R.J.2    Chapman, B.E.3    Young, G.A.R.4    Kuchel, P.W.5
  • 16
    • 26844453721 scopus 로고    scopus 로고
    • A flow-rate independent cell counter using a fixed control volume between double electrical sensing zones
    • Miami, FL
    • D. W. Lee, S. Y. Yi, and Y.-H. Cho, "A flow-rate independent cell counter using a fixed control volume between double electrical sensing zones," in Proc. 18th IEEE Int. Conf. MEMS, Miami, FL, 2005, pp. 678-681.
    • (2005) Proc. 18th IEEE Int. Conf. MEMS , pp. 678-681
    • Lee, D.W.1    Yi, S.Y.2    Cho, Y.-H.3
  • 17
    • 0033876850 scopus 로고    scopus 로고
    • Three-dimensional micro-channel fabrication in polydimethylsiloxane (PDMS) elastomer
    • Mar
    • B.-H. Jo, L. M. Van Lerberghe, K. M. Motsegood, and D. J. Beebe, "Three-dimensional micro-channel fabrication in polydimethylsiloxane (PDMS) elastomer," J. Microelectromech. Syst., vol. 9, no. 1, pp. 76-81, Mar. 2002.
    • (2002) J. Microelectromech. Syst , vol.9 , Issue.1 , pp. 76-81
    • Jo, B.-H.1    Van Lerberghe, L.M.2    Motsegood, K.M.3    Beebe, D.J.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.