메뉴 건너뛰기




Volumn 5, Issue 1, 2008, Pages 28-35

Laboratory and field testing of sampling methods for inhalable and respirable dust

Author keywords

Aerosol monitoring; Cascade impactor; Inhalable dust; IOM samplers; Particle size selective sampling; Respirable dust

Indexed keywords

METAL; MINERAL;

EID: 40449126236     PISSN: 15459624     EISSN: 15459632     Source Type: Journal    
DOI: 10.1080/15459620701763723     Document Type: Article
Times cited : (20)

References (14)
  • 3
    • 0022588080 scopus 로고
    • A new personal sampler for airborne total dust in workplaces
    • Mark, D., and J.H. Vincent: A new personal sampler for airborne total dust in workplaces. Ann. Occup. Hyg. 30(1):89-102 (1986).
    • (1986) Ann. Occup. Hyg. , vol.30 , Issue.1 , pp. 89-102
    • Mark, D.1    Vincent, J.H.2
  • 5
    • 8244264676 scopus 로고    scopus 로고
    • A collaborative European study of personal inhalable aerosol sampler performance
    • Kenny, L.C., R. Aitken, C. Chalmers, et al.: A collaborative European study of personal inhalable aerosol sampler performance. Ann. Occup. Hyg. 41(2):135-153 (1997).
    • (1997) Ann. Occup. Hyg. , vol.41 , Issue.2 , pp. 135-153
    • Kenny, L.C.1    Aitken, R.2    Chalmers, C.3
  • 7
    • 0042734509 scopus 로고    scopus 로고
    • Laboratory and field testing of particle size-selective sampling methods for mineral dusts
    • Teikari, M., M. Linnainmaa, J. Laitinen, et al.: Laboratory and field testing of particle size-selective sampling methods for mineral dusts. Am. Ind. Hyg. Assoc. J. 64:312-318 (2003).
    • (2003) Am. Ind. Hyg. Assoc. J. , vol.64 , pp. 312-318
    • Teikari, M.1    Linnainmaa, M.2    Laitinen, J.3
  • 8
    • 0027683658 scopus 로고
    • Porous plastic foam filtration media: Penetration characteristics and applications in particle size-selective sampling
    • Vincent, J.H., R.J. Aitken, and D. Mark: Porous plastic foam filtration media: Penetration characteristics and applications in particle size-selective sampling. J. Aerosol Sci. 24:929-944 (1993).
    • (1993) J. Aerosol Sci. , vol.24 , pp. 929-944
    • Vincent, J.H.1    Aitken, R.J.2    Mark, D.3
  • 9
    • 0035177681 scopus 로고    scopus 로고
    • Applications of low-cost, dual-fraction dust samplers
    • Kenny, L., K. Chung, M. Dilworth, et al.: Applications of low-cost, dual-fraction dust samplers. Ann. Occup. Hyg. 45:35-42 (2001).
    • (2001) Ann. Occup. Hyg. , vol.45 , pp. 35-42
    • Kenny, L.1    Chung, K.2    Dilworth, M.3
  • 10
    • 0041442981 scopus 로고    scopus 로고
    • Sampling for respirable and fine aerosol
    • J.H. Vincent (ed.). Cincinnati, Ohio: ACGIH
    • John, W.: Sampling for respirable and fine aerosol. In Particle Size-Selective Sampling for Particulate Air Contaminants, J.H. Vincent (ed.). Cincinnati, Ohio: ACGIH, 1999. pp. 155-167.
    • (1999) Particle Size-Selective Sampling for Particulate Air Contaminants , pp. 155-167
    • John, W.1
  • 11
    • 84875679300 scopus 로고    scopus 로고
    • The penetration characteristics of a foam dust sampler at different dust loads
    • Abstracts of the European Aerosol Conference 2004, Budapest, Hungary, September 6-10, 2004
    • Sippula, O., A. Leskinen, J. Laitinen, J. Piirainen, T. Raunemaa, and M. Linnainmaa: The penetration characteristics of a foam dust sampler at different dust loads. Abstracts of the European Aerosol Conference 2004, Budapest, Hungary, September 6-10, 2004. J. Aerosol Sci. 35(Suppl. 1):S327-S328 (2004).
    • (2004) J. Aerosol Sci. , vol.35 , Issue.SUPPL. 1
    • Sippula, O.1    Leskinen, A.2    Laitinen, J.3    Piirainen, J.4    Raunemaa, T.5    Linnainmaa, M.6
  • 12
    • 0030271946 scopus 로고    scopus 로고
    • Inversion techniques for personal cascade impactor data
    • Ramachandran, G., E.W. Johnson, and J.H. Vincent: Inversion techniques for personal cascade impactor data. J. Aerosol. Sci. 27:1083-1097 (1996).
    • (1996) J. Aerosol. Sci. , vol.27 , pp. 1083-1097
    • Ramachandran, G.1    Johnson, E.W.2    Vincent, J.H.3
  • 14


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.