메뉴 건너뛰기




Volumn 64, Issue 3, 2003, Pages 312-318

Laboratory and field testing of particle size-selective sampling methods for mineral dusts

Author keywords

Aerosol monitoring; Cascade impactor; IOM samplers; Mineral dust; Particle size selective sampling

Indexed keywords

MINERAL; TALC;

EID: 0042734509     PISSN: 15428117     EISSN: None     Source Type: Journal    
DOI: 10.1080/15428110308984822     Document Type: Article
Times cited : (24)

References (34)
  • 4
    • 0003678798 scopus 로고    scopus 로고
    • Criteria for a Recommended Standard (DHHS [NIOSH] Pub. no. 98–102). Cincinnati, Ohio: NIOSH
    • National Institute for Occupational Safety and Health (NIOSH): Occupational Exposure to Metalworking Fluids0. Criteria for a Recommended Standard (DHHS [NIOSH] Pub. no. 98–102). Cincinnati, Ohio: NIOSH, 1998.
    • (1998) Occupational Exposure to Metalworking Fluids0
  • 6
    • 0028847317 scopus 로고
    • Occupational exposure to inhalable and total aerosol in the primary nickel production industry
    • Tsai, P.J., J.H. Vincent, G. Wahl, and G. Maldonado: Occupational exposure to inhalable and total aerosol in the primary nickel production industry. Occup. Environ. Med. 52:793–799 (1995).
    • (1995) Occup. Environ. Med , vol.52 , pp. 793-799
    • Tsai, P.J.1    Vincent, J.H.2    Wahl, G.3    Maldonado, G.4
  • 7
    • 0029737282 scopus 로고    scopus 로고
    • Investigation into the impact of introducing workplace aerosol standards based on the inhalable fraction
    • Werner, M.A., T.M. Spear, and J.H. Vincent: Investigation into the impact of introducing workplace aerosol standards based on the inhalable fraction. Analyst 121:1207–1214 (1996).
    • (1996) Analyst , vol.121 , pp. 1207-1214
    • Werner, M.A.1    Spear, T.M.2    Vincent, J.H.3
  • 8
    • 0034058333 scopus 로고    scopus 로고
    • Personal sampling in parallel with open-face filter cassettes and IOM samplers for inhalable dust—implications for occupational exposure limits
    • Lidén, G., B. Melin, A. Lindblom, K. Lindberg, and J-O. Norén: Personal sampling in parallel with open-face filter cassettes and IOM samplers for inhalable dust—implications for occupational exposure limits. Appl. Occup. Environ. Hyg. 15:263–276 (2000).
    • (2000) Appl. Occup. Environ. Hyg , vol.15 , pp. 263-276
    • Lidén, G.1    Melin, B.2    Lindblom, A.3    Lindberg, K.4    Norén, J.-O.5
  • 9
    • 0022588080 scopus 로고
    • A new personal sampler for airborne total dust in workplaces
    • Mark, D., and J.H. Vincent: A new personal sampler for airborne total dust in workplaces. Ann. Occup. Hyg. 30:89–102 (1986).
    • (1986) Ann. Occup. Hyg , vol.30 , pp. 89-102
    • Mark, D.1    Vincent, J.H.2
  • 10
    • 0000059246 scopus 로고    scopus 로고
    • Inhalable aerosol samplers
    • Bartley, D.L.: Inhalable aerosol samplers. Appl. Occup. Environ. Hyg. 13:274–278 (1998).
    • (1998) Appl. Occup. Environ. Hyg , vol.13 , pp. 274-278
    • Bartley, D.L.1
  • 11
    • 8244264676 scopus 로고    scopus 로고
    • A collaborative European study of personal inhalable aerosol sampler performance
    • Kenny, L.C., R. Aitken, C. Chalmers, et al.: A collaborative European study of personal inhalable aerosol sampler performance. Ann. Occup. Hyg. 41:135–153 (1997).
    • (1997) Ann. Occup. Hyg , vol.41 , pp. 135-153
    • Kenny, L.C.1    Aitken, R.2    Chalmers, C.3
  • 12
    • 0036786275 scopus 로고    scopus 로고
    • Personal sampling for inhalable aerosol exposures of carbon black manufacturing industry workers
    • Kerr, S.M., H.J. Muranko, and J.H. Vincent: Personal sampling for inhalable aerosol exposures of carbon black manufacturing industry workers. Appl. Occup. Environ. Hyg. 17:681–692 (2002).
    • (2002) Appl. Occup. Environ. Hyg , vol.17 , pp. 681-692
    • Kerr, S.M.1    Muranko, H.J.2    Vincent, J.H.3
  • 15
    • 0041442981 scopus 로고    scopus 로고
    • Sampling for respirable and fine aerosol
    • In J.H. Vincent, editor, Cincinnati, Ohio: ACGIH
    • John, W.: Sampling for respirable and fine aerosol. In J.H. Vincent, editor, Particle Size-Selective Sampling for Particulate Air Contaminants, pp. 155–167. Cincinnati, Ohio: ACGIH, 1999.
    • (1999) Particle Size-Selective Sampling for Particulate Air Contaminants , pp. 155-167
    • John, W.1
  • 16
    • 0042946087 scopus 로고
    • The Development of Personal Sampler for Inspirable, Thoracic and Respirable Aerosol
    • March 22–24, 1988. Portishead, Bristol, U.K: The Aerosol Society
    • Mark, D., G. Borzucki, G. Lynch, and J.H. Vincent: “The Development of Personal Sampler for Inspirable, Thoracic and Respirable Aerosol.” Proceedings of the Annual Aerosol Society Conference, March 22–24, 1988. Portishead, Bristol, U.K: The Aerosol Society, 1988. pp. 183–187.
    • (1988) Proceedings of the Annual Aerosol Society Conference , pp. 183-187
    • Mark, D.1    Borzucki, G.2    Lynch, G.3    Vincent, J.H.4
  • 17
    • 0027683658 scopus 로고
    • Porous plastic foam filtration media: Penetration characteristics and applications in particle size-selective sampling
    • Vincent, J.H., R.J. Aitken, and D. Mark: Porous plastic foam filtration media: Penetration characteristics and applications in particle size-selective sampling. J. Aerosol Sci. 24:929–944 (1993).
    • (1993) J. Aerosol Sci , vol.24 , pp. 929-944
    • Vincent, J.H.1    Aitken, R.J.2    Mark, D.3
  • 18
    • 0042946084 scopus 로고
    • H. Lo¨dding, and W. Koch: A new personal monitor for real-time measurement of the inspirable, the thoracic, and the respirable fraction of the airborne dust
    • Dunkhorst, W., H. Lo¨dding, and W. Koch: A new personal monitor for real-time measurement of the inspirable, the thoracic, and the respirable fraction of the airborne dust. J. Aerosol Sci. 26(suppl 1):107–108 (1995).
    • (1995) J. Aerosol Sci , vol.26 , pp. 107-108
    • Dunkhorst, W.1
  • 20
    • 0023581659 scopus 로고
    • A personal inspirable aerosol spectrometer for applications in occupational hygiene research
    • Gibson, H., J.H. Vincent, and D. Mark: A personal inspirable aerosol spectrometer for applications in occupational hygiene research. Ann. Occup. Hyg. 31:463–479 (1987).
    • (1987) Ann. Occup. Hyg , vol.31 , pp. 463-479
    • Gibson, H.1    Vincent, J.H.2    Mark, D.3
  • 21
    • 0031452783 scopus 로고    scopus 로고
    • Comparison of methods for personal sampling of inhalable and total lead and cadmium- containing aerosols in a primary lead smelter
    • Spear, T.M., M.A. Werner, J. Bootland, et al.: Comparison of methods for personal sampling of inhalable and total lead and cadmium- containing aerosols in a primary lead smelter. Am. Ind. Hyg. Assoc. J. 58:893–899 (1997).
    • (1997) Am. Ind. Hyg. Assoc. J , vol.58 , pp. 893-899
    • Spear, T.M.1    Werner, M.A.2    Bootland, J.3
  • 22
    • 0029737282 scopus 로고    scopus 로고
    • Investigation into the impact of introducing workplace aerosol standards based on the inhalable fraction
    • Werner, M.A., T.M. Spear, J.H. Vincent: Investigation into the impact of introducing workplace aerosol standards based on the inhalable fraction. Analyst 121:1207–1214 (1996).
    • (1996) Analyst , vol.121 , pp. 1207-1214
    • Werner, M.A.1    Spear, T.M.2    Vincent, J.H.3
  • 23
    • 0029736779 scopus 로고    scopus 로고
    • Assessment of particle size distributions in workers’ aerosol exposures
    • Ramachandran, G., M.A. Werner, and J.H. Vincent: Assessment of particle size distributions in workers’ aerosol exposures. Analyst 121:1225–1232 (1996).
    • (1996) Analyst , vol.121 , pp. 1225-1232
    • Ramachandran, G.1    Werner, M.A.2    Vincent, J.H.3
  • 24
    • 0031022892 scopus 로고    scopus 로고
    • Evaluation of two inversion techniques for retrieving health-related aerosol fractions from personal cascade impactor measurements
    • Ramachandran, G., and J.H. Vincent: Evaluation of two inversion techniques for retrieving health-related aerosol fractions from personal cascade impactor measurements. Am. Ind. Hyg. Assoc. J. 58:15–22 (1997).
    • (1997) Am. Ind. Hyg. Assoc. J , vol.58 , pp. 15-22
    • Ramachandran, G.1    Vincent, J.H.2
  • 25
    • 0034131482 scopus 로고    scopus 로고
    • Particle size characterizations of copper and zinc oxide exposures of employees working in a nonferrous foundry using cascade impactors
    • Cohen, H.J., and B.J. Powers: Particle size characterizations of copper and zinc oxide exposures of employees working in a nonferrous foundry using cascade impactors. Am. Ind. Hyg. Assoc. J. 61:422–430 (2000).
    • (2000) Am. Ind. Hyg. Assoc. J , vol.61 , pp. 422-430
    • Cohen, H.J.1    Powers, B.J.2
  • 26
    • 0027314456 scopus 로고
    • Application of porous foams as size selectors for biologically relevant samplers
    • Aitken, R.J., J.H. Vincent, and D. Mark: Application of porous foams as size selectors for biologically relevant samplers. Appl. Occup. Environ. Hyg. 8:363–369 (1993).
    • (1993) Appl. Occup. Environ. Hyg , vol.8 , pp. 363-369
    • Aitken, R.J.1    Vincent, J.H.2    Mark, D.3
  • 27
    • 0031742391 scopus 로고    scopus 로고
    • The adaption of existing personal inhalable aerosol samplers for bioaerosol sampling
    • Kenny, L.C., J.D. Stancliffe, B. Crook, et al.: The adaption of existing personal inhalable aerosol samplers for bioaerosol sampling. Am. Ind. Hyg. Assoc. J. 59:831–841 (1998).
    • (1998) Am. Ind. Hyg. Assoc. J , vol.59 , pp. 831-841
    • Kenny, L.C.1    Stancliffe, J.D.2    Crook, B.3
  • 28
    • 0033213782 scopus 로고    scopus 로고
    • Measurement of aerosol penetration through size personal thoracic samplers under calm air conditions
    • Maynard, A.D.: Measurement of aerosol penetration through size personal thoracic samplers under calm air conditions. J. Aerosol Sci. 30:1227–1242 (1999).
    • (1999) J. Aerosol Sci , vol.30 , pp. 1227-1242
    • Maynard, A.D.1
  • 29
    • 0035177681 scopus 로고    scopus 로고
    • Applications of low-cost, dual-fraction dust samplers
    • Kenny, L., K. Chung, M. Dilworth, et al.: Applications of low-cost, dual-fraction dust samplers. Ann. Occup. Hyg. 45:35–42 (2001).
    • (2001) Ann. Occup. Hyg , vol.45 , pp. 35-42
    • Kenny, L.1    Chung, K.2    Dilworth, M.3
  • 30
    • 0023238163 scopus 로고
    • Electrical charge characteristics of dry aerosols produced by a number of laboratory mechanical dispensers. Aerosol Sci
    • Johnston, A.M., J.H. Vincent, and A.D. Jones: Electrical charge characteristics of dry aerosols produced by a number of laboratory mechanical dispensers. Aerosol Sci. Tech. 6:115–127 (1987).
    • (1987) Tech , vol.6 , pp. 115-127
    • Johnston, A.M.1    Vincent, J.H.2    Jones, A.D.3
  • 31
    • 0023220258 scopus 로고
    • The effect of electrostatic charge on the aspiration efficiencies of airborne dust samplers with special reference to asbestos
    • Johnston, A.M., A.D. Jones, and J.H. Vincent: The effect of electrostatic charge on the aspiration efficiencies of airborne dust samplers with special reference to asbestos. Am. Ind. Hyg. Assoc. J. 48:613–621 (1987).
    • (1987) Am. Ind. Hyg. Assoc. J , vol.48 , pp. 613-621
    • Johnston, A.M.1    Jones, A.D.2    Vincent, J.H.3
  • 32
    • 0019509871 scopus 로고
    • The penetration of dust through porous foam filter media
    • Gibson, H., and J.H. Vincent: The penetration of dust through porous foam filter media. Ann. Occup. Hyg. 24:205–215 (1981).
    • (1981) Ann. Occup. Hyg , vol.24 , pp. 205-215
    • Gibson, H.1    Vincent, J.H.2
  • 33
    • 0042946085 scopus 로고    scopus 로고
    • Orientation-averaged aspiration efficiency of IOM-like personal aerosol samplers mounted on bluff bodies
    • Paik, S.Y., and J.H. Vincent: Orientation-averaged aspiration efficiency of IOM-like personal aerosol samplers mounted on bluff bodies. Ann. Occup. Hyg. (submitted)
    • Ann. Occup. Hyg
    • Paik, S.Y.1    Vincent, J.H.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.