메뉴 건너뛰기




Volumn 94, Issue 1, 2008, Pages 87-91

Thirty-four years follow-up of a bilateral Mac Kee-Farrar arthroplasty without loosening or osteolysis;Absence d'ostéolyse et de descellement d'une arthroplastie bilatérale de Mac Kee-Farrar à 34 ans de recul

Author keywords

Cobalt blood levels; Hip prosthesis; Mac Kee Farrar prosthesis; Metal on metal; Prosthesis loosening

Indexed keywords

AGED; ARTICLE; CASE REPORT; FEMALE; FOLLOW UP; HIP ARTHROPLASTY; HIP PROSTHESIS; HUMAN; METHODOLOGY; PROSTHESIS; TIME;

EID: 39849090323     PISSN: 00351040     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.rco.2007.11.002     Document Type: Article
Times cited : (1)

References (21)
  • 2
    • 0029926609 scopus 로고    scopus 로고
    • Survie à plus de 15 ans de prothèses métal-métal de Mac Kee-Farrar. À propos de 58 observations et de 4 cupules explantées
    • Ray A. Survie à plus de 15 ans de prothèses métal-métal de Mac Kee-Farrar. À propos de 58 observations et de 4 cupules explantées. Rev Chir Orthop 82 (1996) 85-89
    • (1996) Rev Chir Orthop , vol.82 , pp. 85-89
    • Ray, A.1
  • 3
    • 0029882821 scopus 로고    scopus 로고
    • Long-duration metal-on-metal total hip arthroplasties with low wear of the articulating surfaces
    • Schmalzried T.P., Peters P.C., Maurer B.T., Bragdon C.R., and Harris W.H. Long-duration metal-on-metal total hip arthroplasties with low wear of the articulating surfaces. J Arthroplasty 11 (1996) 322-331
    • (1996) J Arthroplasty , vol.11 , pp. 322-331
    • Schmalzried, T.P.1    Peters, P.C.2    Maurer, B.T.3    Bragdon, C.R.4    Harris, W.H.5
  • 5
    • 20444381731 scopus 로고    scopus 로고
    • Long-term clinical, radiological and histopathological follow-up of a well-fixed McKee-Farrar metal-on-metal total hip arthroplasty
    • Clarke M.T., Darrah C., Stewart T., Ingham E., Fisher J., and Nolan J.F. Long-term clinical, radiological and histopathological follow-up of a well-fixed McKee-Farrar metal-on-metal total hip arthroplasty. J Arthroplasty 20 (2005) 542-547
    • (2005) J Arthroplasty , vol.20 , pp. 542-547
    • Clarke, M.T.1    Darrah, C.2    Stewart, T.3    Ingham, E.4    Fisher, J.5    Nolan, J.F.6
  • 6
    • 0019776993 scopus 로고
    • Mc Kee total hip arthroplasty. A review of 1,000 cases
    • Gandin J., Gandin R., Boye P., Badosa A., et al. Mc Kee total hip arthroplasty. A review of 1,000 cases. Rev Chir Orthop 67 (1981) 587-591
    • (1981) Rev Chir Orthop , vol.67 , pp. 587-591
    • Gandin, J.1    Gandin, R.2    Boye, P.3    Badosa, A.4
  • 7
    • 0029790388 scopus 로고    scopus 로고
    • Twenty-year results of McKee-Farrar versus Charnley prosthesis
    • Jacobsson S.A., Djerf K., and Wahlstrom O. Twenty-year results of McKee-Farrar versus Charnley prosthesis. Clin Orthop Suppl. 329 (1996) 60-68
    • (1996) Clin Orthop , vol.SUPPL. 329 , pp. 60-68
    • Jacobsson, S.A.1    Djerf, K.2    Wahlstrom, O.3
  • 8
    • 0036714774 scopus 로고    scopus 로고
    • Long term survival of Mc Kee-Farrar total hip prostheses
    • Brown S.R., Davies W.A., Deheer D.H., and Swanson A.B. Long term survival of Mc Kee-Farrar total hip prostheses. Clin Orthop 402 (2002) 157-163
    • (2002) Clin Orthop , vol.402 , pp. 157-163
    • Brown, S.R.1    Davies, W.A.2    Deheer, D.H.3    Swanson, A.B.4
  • 9
    • 0032932612 scopus 로고    scopus 로고
    • Lessons learned from loosening of the Mc Kee-Farrar metal-on-metal tota hip replacement
    • Zahiri C.A., Schmalzried T.P., Ebramzadeh E., et al. Lessons learned from loosening of the Mc Kee-Farrar metal-on-metal tota hip replacement. J Arthroplasty 14 (1999) 326-332
    • (1999) J Arthroplasty , vol.14 , pp. 326-332
    • Zahiri, C.A.1    Schmalzried, T.P.2    Ebramzadeh, E.3
  • 10
    • 0029187931 scopus 로고
    • Fractures of the femur after hip replacement
    • Jackson (Ed)
    • Duncan C.P., and Masri B.A. Fractures of the femur after hip replacement. In: Jackson (Ed). Instructional course lecture 44 (1995) 293-304
    • (1995) Instructional course lecture , vol.44 , pp. 293-304
    • Duncan, C.P.1    Masri, B.A.2
  • 11
    • 0033983833 scopus 로고    scopus 로고
    • The reliability of validity of the Vancouver classification of femoral fractures after hip replacement
    • Brady O.H., Garbuz D.S., Masri B.A., and Duncan C.P. The reliability of validity of the Vancouver classification of femoral fractures after hip replacement. J Arthroplasty 15 (2000) 59-62
    • (2000) J Arthroplasty , vol.15 , pp. 59-62
    • Brady, O.H.1    Garbuz, D.S.2    Masri, B.A.3    Duncan, C.P.4
  • 12
    • 0344027091 scopus 로고
    • Cotation chiffrée de la function de la hanche
    • Merle d'Aubigne R. Cotation chiffrée de la function de la hanche. Rev Chir Orthop 76 (1990) 371-374
    • (1990) Rev Chir Orthop , vol.76 , pp. 371-374
    • Merle d'Aubigne, R.1
  • 13
    • 0031544132 scopus 로고    scopus 로고
    • Three-dimensional polyethylene wear of a pressfit titanium prosthesis. Factors influencing generation of polyethylene debris
    • Devane P.A., Horne J.G., Martin K., Coldham G., and Krause B. Three-dimensional polyethylene wear of a pressfit titanium prosthesis. Factors influencing generation of polyethylene debris. J Arthroplasty 12 (1997) 256-266
    • (1997) J Arthroplasty , vol.12 , pp. 256-266
    • Devane, P.A.1    Horne, J.G.2    Martin, K.3    Coldham, G.4    Krause, B.5
  • 14
    • 0020958051 scopus 로고
    • Les luxations des prothèses de hanche
    • Laburthe Tolra Y. Les luxations des prothèses de hanche. Chirurgie 109 (1983) 785-789
    • (1983) Chirurgie , vol.109 , pp. 785-789
    • Laburthe Tolra, Y.1
  • 15
    • 0036787572 scopus 로고    scopus 로고
    • An algorithm for the treatment of Vancouver type B2 periprosthetic proximal femoral fractures
    • Sledge J.B., and Abiri A. An algorithm for the treatment of Vancouver type B2 periprosthetic proximal femoral fractures. J Arthroplasty 17 (2002) 887-892
    • (2002) J Arthroplasty , vol.17 , pp. 887-892
    • Sledge, J.B.1    Abiri, A.2
  • 16
    • 39849084748 scopus 로고    scopus 로고
    • Courpied JP. Fractures fémorales autour des prothèses totales de la hanche. In: Cahiers d'enseignement de la SOFCOT, 73. Éd. Elsevier ; 2000. p. 119-138.
    • Courpied JP. Fractures fémorales autour des prothèses totales de la hanche. In: Cahiers d'enseignement de la SOFCOT, 73. Éd. Elsevier ; 2000. p. 119-138.
  • 17
    • 0037591631 scopus 로고    scopus 로고
    • Distal fixation with Wagner revision stem in treating Vancouver type B2 periprosthetic femur fractures in geriatric patients
    • Ko P.S., Lam J.J., Tio M.K., Lee O.B., and Ip F.K. Distal fixation with Wagner revision stem in treating Vancouver type B2 periprosthetic femur fractures in geriatric patients. J Arthroplasty 18 (2003) 446-452
    • (2003) J Arthroplasty , vol.18 , pp. 446-452
    • Ko, P.S.1    Lam, J.J.2    Tio, M.K.3    Lee, O.B.4    Ip, F.K.5
  • 18
    • 33746929124 scopus 로고    scopus 로고
    • Is removal of subchondral bone plate advantageous in cemented cup fixation? A randomized RSA study
    • Flivik G., Kristiansson I., Kesteris U., and Ryd L. Is removal of subchondral bone plate advantageous in cemented cup fixation? A randomized RSA study. Clin Orthop Relat Res 448 (2006) 164-172
    • (2006) Clin Orthop Relat Res , vol.448 , pp. 164-172
    • Flivik, G.1    Kristiansson, I.2    Kesteris, U.3    Ryd, L.4
  • 19
    • 39849106137 scopus 로고    scopus 로고
    • Bouraly JP. Métallurgie du métal métal appliqué à l'arthroplastie totale de hanche. Prothèse totale de hanche : les choix. In: Cahiers d'enseignement de la SOFCOT, 90. Éd. Elsevier ; 2005. p. 47-55.
    • Bouraly JP. Métallurgie du métal métal appliqué à l'arthroplastie totale de hanche. Prothèse totale de hanche : les choix. In: Cahiers d'enseignement de la SOFCOT, 90. Éd. Elsevier ; 2005. p. 47-55.
  • 20
    • 2642543336 scopus 로고    scopus 로고
    • Dosages sanguins de métaux chez 48 patients porteurs d'une prothèse totale de hanche en chrome-cobalt à couple métal-polyéthylène
    • Damie F., and Favard l. Dosages sanguins de métaux chez 48 patients porteurs d'une prothèse totale de hanche en chrome-cobalt à couple métal-polyéthylène. Rev Chir Orthop 90 (2004) 241-248
    • (2004) Rev Chir Orthop , vol.90 , pp. 241-248
    • Damie, F.1    Favard, l.2
  • 21
    • 0033056715 scopus 로고    scopus 로고
    • Intérêt et limite du dosage du cobalt sérique chez les patients porteurs d'une prothèse à couple métal métal
    • Gleizes V., Poupon J., Lazennec J.Y., Chamberlin B., and Saillant G. Intérêt et limite du dosage du cobalt sérique chez les patients porteurs d'une prothèse à couple métal métal. Rev Chir Orthop 85 (1999) 217-225
    • (1999) Rev Chir Orthop , vol.85 , pp. 217-225
    • Gleizes, V.1    Poupon, J.2    Lazennec, J.Y.3    Chamberlin, B.4    Saillant, G.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.