메뉴 건너뛰기




Volumn 19, Issue 3, 2008, Pages 270-274

Sensing failure associated with the Medtronic Sprint Fidelis defibrillator lead

Author keywords

Implantable cardioverter defibrillator; Implantable devices; Lead implantation; Lead revision; Pacing threshold; Sensing threshold

Indexed keywords

ADULT; AGED; ARTICLE; DEFIBRILLATOR; DEMOGRAPHY; DEVICE; FEMALE; FOLLOW UP; HEART VENTRICLE FIBRILLATION; HEART VENTRICLE TACHYCARDIA; HUMAN; KAPLAN MEIER METHOD; MAJOR CLINICAL STUDY; MALE; PRIORITY JOURNAL; R WAVE; RETROSPECTIVE STUDY; STATISTICAL ANALYSIS;

EID: 39749143934     PISSN: 10453873     EISSN: 15408167     Source Type: Journal    
DOI: 10.1111/j.1540-8167.2007.01058.x     Document Type: Article
Times cited : (22)

References (15)
  • 3
    • 34248579318 scopus 로고    scopus 로고
    • Annual rate of transvenous defibrillation lead defects in implantable cardioverter-defibrillators over a period of >10 years
    • Thomas K, Torsten B, Klaus D, Margit V, Jochen S, Steffen S, Werner S, Udo W, Karlheinz S : Annual rate of transvenous defibrillation lead defects in implantable cardioverter-defibrillators over a period of >10 years. Circulation 2007 115 : 2474 2480.
    • (2007) Circulation , vol.115 , pp. 2474-2480
    • Thomas, K.1    Torsten, B.2    Klaus, D.3    Margit, V.4    Jochen, S.5    Steffen, S.6    Werner, S.7    Udo, W.8    Karlheinz, S.9
  • 4
    • 0035336187 scopus 로고    scopus 로고
    • Implantation of cardioverter defibrillators without induction of ventricular fibrillation
    • Swerdlow CD : Implantation of cardioverter defibrillators without induction of ventricular fibrillation. Circulation 2001 103 : 2159 2164.
    • (2001) Circulation , vol.103 , pp. 2159-2164
    • Swerdlow, C.D.1
  • 5
    • 0026773134 scopus 로고
    • Short-term reproducibility over time of right ventricular pulse pressure as a potential hemodynamic sensor for ventricular tachyarrhythmias
    • Ellenbogen KA, Wood MA, Kapadia K, Lu B, Valenta H : Short-term reproducibility over time of right ventricular pulse pressure as a potential hemodynamic sensor for ventricular tachyarrhythmias. Pacing Clin Electrophysiol 1992 15 : 971 974.
    • (1992) Pacing Clin Electrophysiol , vol.15 , pp. 971-974
    • Ellenbogen, K.A.1    Wood, M.A.2    Kapadia, K.3    Lu, B.4    Valenta, H.5
  • 7
    • 0026733276 scopus 로고
    • Measurement of ventricular electrogram amplitude during intraoperative induction of ventricular tachyarrhythmias
    • Ellenbogen KA, Wood MA, Stambler BS, Welch WJ, Damiano RJ : Measurement of ventricular electrogram amplitude during intraoperative induction of ventricular tachyarrhythmias. Am J Cardiol 1992 70 : 1017 1022.
    • (1992) Am J Cardiol , vol.70 , pp. 1017-1022
    • Ellenbogen, K.A.1    Wood, M.A.2    Stambler, B.S.3    Welch, W.J.4    Damiano, R.J.5
  • 8
    • 39749188646 scopus 로고    scopus 로고
    • Engineering and construction of pacemaker and implantable cardioverter defibrillator leads
    • In: Ellenbogen, K.A., Kay, G.N., Lau, C.P., Wilkoff, B.L., eds. Philadelphia, WB Saunders
    • Russo AM, Marchlinski FR : Engineering and construction of pacemaker and implantable cardioverter defibrillator leads. In : Ellenbogen KA, Kay GN, Lau CP, Wilkoff BL, eds. Clinical Cardiac Pacing, Defibrillation, and Resynchronization Therapy, 3rd ed. Philadelphia, WB Saunders, 2000 : 161 200.
    • (2000) Clinical Cardiac Pacing, Defibrillation, and Resynchronization Therapy, 3rd Ed. , pp. 161-200
    • Russo, A.M.1    Marchlinski, F.R.2
  • 9
    • 39749094272 scopus 로고    scopus 로고
    • RE: Physician information - Sprint Fidelis lead
    • Groves R: Minneapolis, MN: Medtronic. 21 March
    • Groves R : RE: Physician information - Sprint Fidelis lead. Letter. Minneapolis, MN : Medtronic 21 March, 2007.
    • (2007) Letter.
  • 13
    • 34248530016 scopus 로고    scopus 로고
    • Transvenous implantable cardioverter-defibrillator leads: The weakest link
    • Maisel WH : Transvenous implantable cardioverter-defibrillator leads: The weakest link. Circulation 2007 115 : 2461 2463.
    • (2007) Circulation , vol.115 , pp. 2461-2463
    • Maisel, W.H.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.