메뉴 건너뛰기




Volumn 103, Issue 17, 2001, Pages 2159-2164

Implantation of cardioverter defibrillators without induction of ventricular fibrillation

Author keywords

Defibrillation; Defibrillators, implantable; Shock

Indexed keywords

ADULT; AGED; ARTICLE; DEFIBRILLATOR; ECHOCARDIOGRAPHY; ELECTROPHYSIOLOGY; FEMALE; HEART VENTRICLE FIBRILLATION; HEART VENTRICLE TACHYCARDIA; HUMAN; IMPLANTATION; MAJOR CLINICAL STUDY; MALE; PRIORITY JOURNAL; T WAVE;

EID: 0035336187     PISSN: 00097322     EISSN: None     Source Type: Journal    
DOI: 10.1161/01.CIR.103.17.2159     Document Type: Article
Times cited : (61)

References (26)
  • 1
    • 0026871028 scopus 로고
    • Clinical evaluation of the safety of repetitive intraoperative defibrillation threshold testing
    • Frame R, Brodman R, Furman S, et al. Clinical evaluation of the safety of repetitive intraoperative defibrillation threshold testing. Pacing Clin Electrophysiol. 1992;15:870-877.
    • (1992) Pacing Clin Electrophysiol , vol.15 , pp. 870-877
    • Frame, R.1    Brodman, R.2    Furman, S.3
  • 2
    • 0026877545 scopus 로고
    • Defibrillation threshold: Clinical utility and therapeutic implications
    • Singer I, Lang D. Defibrillation threshold: clinical utility and therapeutic implications. Pacing Clin Electrophysiol. 1992;15:932-949.
    • (1992) Pacing Clin Electrophysiol , vol.15 , pp. 932-949
    • Singer, I.1    Lang, D.2
  • 3
    • 0024503844 scopus 로고
    • Defibrillation threshold testing: Necessary but evil?
    • Vlay SC. Defibrillation threshold testing: necessary but evil? Am Heart J. 1989;117:499-504.
    • (1989) Am Heart J , vol.117 , pp. 499-504
    • Vlay, S.C.1
  • 4
    • 85037416126 scopus 로고    scopus 로고
    • Ventricular fibrillation sensing and detection by implantable defibrillators: Is one better than the others? A prospective, comparative study
    • In press
    • Panotopoulos P, Krum D, Axtell K, et al. Ventricular fibrillation sensing and detection by implantable defibrillators: is one better than the others? A prospective, comparative study. J Cardiovasc Electrophysiol. In press.
    • J Cardiovasc Electrophysiol
    • Panotopoulos, P.1    Krum, D.2    Axtell, K.3
  • 5
    • 0028804341 scopus 로고
    • Adequacy of implantable cardioverter-defibrillator lead placement for tachyarrhythmia detection by sinus rhythm electrogram amplitude
    • Michelson BI, Igel DA, Wilkoff BL. Adequacy of implantable cardioverter-defibrillator lead placement for tachyarrhythmia detection by sinus rhythm electrogram amplitude. Am J Cardiol. 1995;76:1162-1166.
    • (1995) Am J Cardiol , vol.76 , pp. 1162-1166
    • Michelson, B.I.1    Igel, D.A.2    Wilkoff, B.L.3
  • 7
    • 0030005068 scopus 로고    scopus 로고
    • Upper limit of vulnerability is a good estimator of shock strength associated with 90% probability of successful defibrillation in humans with transvenous implantable cardioverter defibrillators
    • Swerdlow C, Ahem T, Kass R, et al. Upper limit of vulnerability is a good estimator of shock strength associated with 90% probability of successful defibrillation in humans with transvenous implantable cardioverter defibrillators. J Am Coll Cardiol. 1996;27:1112-1117.
    • (1996) J Am Coll Cardiol , vol.27 , pp. 1112-1117
    • Swerdlow, C.1    Ahem, T.2    Kass, R.3
  • 8
    • 0030933633 scopus 로고    scopus 로고
    • Upper limit of vulnerability predicts chronic defibrillation threshold for transvenous implantable defibrillators
    • Martin DJ, Chen PS, Hwang C, et al. Upper limit of vulnerability predicts chronic defibrillation threshold for transvenous implantable defibrillators. J Cardiovasc Electrophysiol. 1997;8:241-248.
    • (1997) J Cardiovasc Electrophysiol , vol.8 , pp. 241-248
    • Martin, D.J.1    Chen, P.S.2    Hwang, C.3
  • 9
    • 16944364388 scopus 로고    scopus 로고
    • Programming of implantable cardioverter-defibrillators on the basis of the upper limit of vulnerability
    • Swerdlow CD, Peter CT, Kass RM, et al. Programming of implantable cardioverter-defibrillators on the basis of the upper limit of vulnerability. Circulation. 1997;95:1497-1504.
    • (1997) Circulation , vol.95 , pp. 1497-1504
    • Swerdlow, C.D.1    Peter, C.T.2    Kass, R.M.3
  • 11
    • 0033977027 scopus 로고    scopus 로고
    • Are routine arrhythmia inductions necessary in patients with pectoral implantable cardioverter defibrillators?
    • Glikson M, Luria D, Friedman PA, et al. Are routine arrhythmia inductions necessary in patients with pectoral implantable cardioverter defibrillators? J Cardiovasc Electrophysiol. 2000;11:127-135.
    • (2000) J Cardiovasc Electrophysiol , vol.11 , pp. 127-135
    • Glikson, M.1    Luria, D.2    Friedman, P.A.3
  • 12
    • 0031696254 scopus 로고    scopus 로고
    • One year experience with a new, steroid eluting, tined defibrillation lead: Results of a prospective, randomised, multicentre comparison with a conventional, screw-in defibrillation lead
    • Hurst T, Waldecker B. One year experience with a new, steroid eluting, tined defibrillation lead: results of a prospective, randomised, multicentre comparison with a conventional, screw-in defibrillation lead. Eur J Pacing Electrophysiol. 1998;8:11-16.
    • (1998) Eur J Pacing Electrophysiol , vol.8 , pp. 11-16
    • Hurst, T.1    Waldecker, B.2
  • 13
    • 18344415385 scopus 로고    scopus 로고
    • Safety and efficacy of implantable defibrillator therapy with programmed shock energy at twice the augmented step-down defibrillation threshold: Results of the prospective, randomized, multicenter low-energy Endotak trial
    • Neuzner J, Liebrich A, Jung J, et al. Safety and efficacy of implantable defibrillator therapy with programmed shock energy at twice the augmented step-down defibrillation threshold: results of the prospective, randomized, multicenter low-energy Endotak trial. Am J Cardiol. 1999; 83:34D-39D.
    • (1999) Am J Cardiol , vol.83
    • Neuzner, J.1    Liebrich, A.2    Jung, J.3
  • 14
    • 0028941942 scopus 로고
    • Ventricular arrhythmias detected after transvenous defibrillator implantation in patients with a clinical history of only ventricular fibrillation: Implications for use of implantable defibrillator
    • Raitt MH, Dolack GL, Kudenchuk PJ, et al. Ventricular arrhythmias detected after transvenous defibrillator implantation in patients with a clinical history of only ventricular fibrillation: implications for use of implantable defibrillator. Circulation. 1995;91:1996-2001.
    • (1995) Circulation , vol.91 , pp. 1996-2001
    • Raitt, M.H.1    Dolack, G.L.2    Kudenchuk, P.J.3
  • 15
    • 0028806445 scopus 로고
    • Benefits and lessons learned from stored electrogram information in implantable defibrillators
    • Marchlinski FE, Callans DJ, Gottlieb CD, et al. Benefits and lessons learned from stored electrogram information in implantable defibrillators. J Cardiovasc Electrophysiol. 1995;6:832-851.
    • (1995) J Cardiovasc Electrophysiol , vol.6 , pp. 832-851
    • Marchlinski, F.E.1    Callans, D.J.2    Gottlieb, C.D.3
  • 16
    • 7144263271 scopus 로고
    • Safety margin for defibrillation
    • Alt E, Klein H, Griffin JC, eds. Berlin: Springer-Verlag
    • Lang DJ, Swanson DK. Safety margin for defibrillation. In: Alt E, Klein H, Griffin JC, eds. The Implantable Cardioverter/Defibrillator. Berlin: Springer-Verlag; 1992:272-279.
    • (1992) The Implantable Cardioverter/Defibrillator , pp. 272-279
    • Lang, D.J.1    Swanson, D.K.2
  • 17
    • 0028120785 scopus 로고
    • Dysfunction and safety factor strength-duration curves for biphasic defibrillator waveforms
    • Jones JL, Milne KB. Dysfunction and safety factor strength-duration curves for biphasic defibrillator waveforms. Am J Physiol. 1994;266: H263-H271.
    • (1994) Am J Physiol , vol.266
    • Jones, J.L.1    Milne, K.B.2
  • 18
    • 15644375417 scopus 로고    scopus 로고
    • Effect of ventricular shock strength on cardiac hemodynamics
    • Tokano T, Bach D, Chang J, et al. Effect of ventricular shock strength on cardiac hemodynamics. J Cardiovasc Electrophysiol. 1998;9:791-797.
    • (1998) J Cardiovasc Electrophysiol , vol.9 , pp. 791-797
    • Tokano, T.1    Bach, D.2    Chang, J.3
  • 19
    • 0025248802 scopus 로고
    • Conduction disturbances caused by high current density electric fields
    • Yabe S, Smith WM, Daubert JP. Conduction disturbances caused by high current density electric fields. Circ Res. 1990;66:1190-1203.
    • (1990) Circ Res , vol.66 , pp. 1190-1203
    • Yabe, S.1    Smith, W.M.2    Daubert, J.P.3
  • 20
    • 10144257863 scopus 로고    scopus 로고
    • Circadian variation in defibrillation energy requirements
    • Venditti FJ Jr, John RM, Hull M, et al. Circadian variation in defibrillation energy requirements. Circulation. 1996;94:1607-1612.
    • (1996) Circulation , vol.94 , pp. 1607-1612
    • Venditti Jr., F.J.1    John, R.M.2    Hull, M.3
  • 21
    • 0033081491 scopus 로고    scopus 로고
    • A stepwise testing protocol for modern implantable cardioverter-defibrillator systems to prevent pacemaker-implantable cardioverter-defibrillator interactions
    • Glikson M, Trusty JM, Grice SK, et al. A stepwise testing protocol for modern implantable cardioverter-defibrillator systems to prevent pacemaker-implantable cardioverter-defibrillator interactions. Am J Cardiol. 1999;83:360-366.
    • (1999) Am J Cardiol , vol.83 , pp. 360-366
    • Glikson, M.1    Trusty, J.M.2    Grice, S.K.3
  • 22
    • 0031694914 scopus 로고    scopus 로고
    • Electromagnetic interference from a muscle stimulation device causing discharge of an implantable cardioverter defibrillator: Epicardial bipolar and endocardial bipolar sensing circuits are compared
    • Glotzer TV, Gordon M, Sparta M, et al. Electromagnetic interference from a muscle stimulation device causing discharge of an implantable cardioverter defibrillator: epicardial bipolar and endocardial bipolar sensing circuits are compared. Pacing Clin Electrophysiol. 1998;21: 1996-1998.
    • (1998) Pacing Clin Electrophysiol , vol.21 , pp. 1996-1998
    • Glotzer, T.V.1    Gordon, M.2    Sparta, M.3
  • 23
    • 0030041635 scopus 로고    scopus 로고
    • Undetected ventricular fibrillation in transvenous implantable cardioverter-defibrillators: Prospective comparison of different lead system-device combinations
    • Natale A, Sra J, Axtell K, et al. Undetected ventricular fibrillation in transvenous implantable cardioverter-defibrillators: prospective comparison of different lead system-device combinations. Circulation. 1996; 93:91-98.
    • (1996) Circulation , vol.93 , pp. 91-98
    • Natale, A.1    Sra, J.2    Axtell, K.3
  • 24
    • 0030671569 scopus 로고    scopus 로고
    • Reproducibility of ventricular fibrillation characteristics in patients undergoing implantable cardioverter defibrillator implantation
    • Taneja T, Goldberger J, Parker MA, et al. Reproducibility of ventricular fibrillation characteristics in patients undergoing implantable cardioverter defibrillator implantation. J Cardiovasc Electrophysiol. 1997;8: 1209-1217.
    • (1997) J Cardiovasc Electrophysiol , vol.8 , pp. 1209-1217
    • Taneja, T.1    Goldberger, J.2    Parker, M.A.3
  • 25
    • 0026726591 scopus 로고
    • Failure of an implantable cardioverter-defibrillator to redetect ventricular fibrillation in patients with a nonthoracotomy lead system
    • Jung M, Manz M, Moosdorf R, et al. Failure of an implantable cardioverter-defibrillator to redetect ventricular fibrillation in patients with a nonthoracotomy lead system. Circulation. 1992;86:1217-1222.
    • (1992) Circulation , vol.86 , pp. 1217-1222
    • Jung, M.1    Manz, M.2    Moosdorf, R.3
  • 26
    • 0030220823 scopus 로고    scopus 로고
    • Multicenter experience with a pectoral unipolar implantable defibrillator
    • Bardy G, Yee R, Jung W. Multicenter experience with a pectoral unipolar implantable defibrillator. J Am Coll Cardiol. 1996;28:400-410.
    • (1996) J Am Coll Cardiol , vol.28 , pp. 400-410
    • Bardy, G.1    Yee, R.2    Jung, W.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.