Volumn 22, Issue 2, 2008, Pages 333-336

Comparison of blade temperature dynamics after activation of Harmonic Ace Scalpel and the Ultracision Harmonic Scalpel LCS-K5

Author keywords

[No Author keywords available]

Indexed keywords

ANIMAL TISSUE; ARTICLE; CHICKEN; COMPARATIVE STUDY; CONTROLLED STUDY; COOLING; DEVICE; DISSECTION; HYPERTHERMIA; NONHUMAN; PRIORITY JOURNAL; ROOM TEMPERATURE; SCALPEL; TEMPERATURE MEASUREMENT; THERMODYNAMICS; VIBRATION;

EID: 39749087579     PISSN: 08927790     EISSN: None     Source Type: Journal    
DOI: 10.1089/end.2007.0169     Document Type: Article
Times cited : (31)

References (10)
  • 2
    • 0035324569 scopus 로고    scopus 로고
    • Experimental study of monopolar electrical and ultrasonic dissection]
    • Antonutti R, Fontes-Dislaire I, Rumeau JL, et al. [Experimental study of monopolar electrical and ultrasonic dissection]. Ann Chir 2001;126:330.
    • (2001) Ann Chir , vol.126 , pp. 330
    • Antonutti, R.1    Fontes-Dislaire, I.2    Rumeau, J.L.3
  • 3
    • 20844451156 scopus 로고    scopus 로고
    • Comparison of experimental nerve injury caused by ultrasonically activated scalpel and electrosurgery
    • Carlander J, Johansson K, Lindstrom S, et al. Comparison of experimental nerve injury caused by ultrasonically activated scalpel and electrosurgery. Br J Surg 2005;92:772.
    • (2005) Br J Surg , vol.92 , pp. 772
    • Carlander, J.1    Johansson, K.2    Lindstrom, S.3
  • 4
    • 0033042428 scopus 로고    scopus 로고
    • Experimental study on heat production by a 23.5-kHz ultrasonically activated device for endoscopic surgery
    • Kinoshita T, Kanehira E, Omura K, et al. Experimental study on heat production by a 23.5-kHz ultrasonically activated device for endoscopic surgery. Surg Endosc 1999;13:621.
    • (1999) Surg Endosc , vol.13 , pp. 621
    • Kinoshita, T.1    Kanehira, E.2    Omura, K.3
  • 5
    • 85047693399 scopus 로고    scopus 로고
    • How safe is high-power ultrasonic dissection?
    • Emam TA, Cuschieri A. How safe is high-power ultrasonic dissection? Ann Surg 2003;237:186.
    • (2003) Ann Surg , vol.237 , pp. 186
    • Emam, T.A.1    Cuschieri, A.2
  • 6
    • 0036289566 scopus 로고    scopus 로고
    • The ultrasonic coagulating and cutting system injures nerve function
    • Owaki T, Nakano S, Arimura K, et al. The ultrasonic coagulating and cutting system injures nerve function. Endoscopy 2002;34:575.
    • (2002) Endoscopy , vol.34 , pp. 575
    • Owaki, T.1    Nakano, S.2    Arimura, K.3
  • 7
    • 1942454784 scopus 로고    scopus 로고
    • The histological effect of harmonic scalpel and electrocautery in lung resections. An experimental study in a rat model
    • Cakan A, Cagirici U, Cikirikcioglu M, et al. The histological effect of harmonic scalpel and electrocautery in lung resections. An experimental study in a rat model. J Cardiovasc Surg (Torino) 2004;45:63.
    • (2004) J Cardiovasc Surg (Torino) , vol.45 , pp. 63
    • Cakan, A.1    Cagirici, U.2    Cikirikcioglu, M.3
  • 8
    • 0030915398 scopus 로고    scopus 로고
    • Proximity injury by the ultrasonically activated scalpel during dissection
    • Kadesky KM, Schopf B, Magee JF, et al. Proximity injury by the ultrasonically activated scalpel during dissection. J Pediatr Surg 1997;32:878.
    • (1997) J Pediatr Surg , vol.32 , pp. 878
    • Kadesky, K.M.1    Schopf, B.2    Magee, J.F.3
  • 9
    • 0029777450 scopus 로고    scopus 로고
    • The harmonic scalpel: An intraoperative complication
    • Awwad JT, Isaacson K. The harmonic scalpel: An intraoperative complication. Obstet Gynecol 1996;88:718.
    • (1996) Obstet Gynecol , vol.88 , pp. 718
    • Awwad, J.T.1    Isaacson, K.2
  • 10
    • 0028228285 scopus 로고
    • Experimental nerve thermal injury
    • Xu D, Pollock M. Experimental nerve thermal injury. Brain 1994;117(Pt 2):375.
    • (1994) Brain , vol.117 , Issue.PART 2 , pp. 375
    • Xu, D.1    Pollock, M.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.