메뉴 건너뛰기




Volumn 92, Issue 6, 2005, Pages 772-777

Comparison of experimental nerve injury caused by ultrasonically activated scalpel and electrosurgery

Author keywords

[No Author keywords available]

Indexed keywords

ANIMAL EXPERIMENT; ANIMAL MODEL; ANIMAL TISSUE; ARTICLE; BICEPS BRACHII MUSCLE; CONTROLLED STUDY; ELECTROMYOGRAM; ELECTROSURGERY; HEAT INJURY; HISTOPATHOLOGY; IATROGENIC DISEASE; NERVE INJURY; NONHUMAN; PRIORITY JOURNAL; RAT; SAFETY; SCALPEL; SCIATIC NERVE; SURGICAL INSTRUMENT; ULTRASOUND;

EID: 20844451156     PISSN: 00071323     EISSN: None     Source Type: Journal    
DOI: 10.1002/bjs.4948     Document Type: Article
Times cited : (58)

References (12)
  • 1
    • 0036446452 scopus 로고    scopus 로고
    • Bladder and sexual dysfunction following laparoscopically assisted and conventional open mesorectal resection for cancer
    • Quah HM, Jayne DG, Eu KW, Seow-Choen F. Bladder and sexual dysfunction following laparoscopically assisted and conventional open mesorectal resection for cancer. Br J Surg 2002; 89: 1551-1556.
    • (2002) Br J Surg , vol.89 , pp. 1551-1556
    • Quah, H.M.1    Jayne, D.G.2    Eu, K.W.3    Seow-Choen, F.4
  • 2
    • 0036165480 scopus 로고    scopus 로고
    • Erectile dysfunction after radical prostatectomy: Hemodynamic profiles and their correlation with the recovery of erectile function
    • Mulhall JP, Slovick R, Hotaling J, Aviv N, Valenzuela R, Waters WB et al. Erectile dysfunction after radical prostatectomy: hemodynamic profiles and their correlation with the recovery of erectile function. J Urol 2002; 167: 1371-1375.
    • (2002) J Urol , vol.167 , pp. 1371-1375
    • Mulhall, J.P.1    Slovick, R.2    Hotaling, J.3    Aviv, N.4    Valenzuela, R.5    Waters, W.B.6
  • 3
    • 0029003847 scopus 로고
    • Pain and other symptoms after different treatment modalities of breast cancer
    • Tasmuth T, von Smitten K, Hietanen P, Kataja M, Kalso E. Pain and other symptoms after different treatment modalities of breast cancer. Ann Oncol 1995; 6: 453-459.
    • (1995) Ann Oncol , vol.6 , pp. 453-459
    • Tasmuth, T.1    Von Smitten, K.2    Hietanen, P.3    Kataja, M.4    Kalso, E.5
  • 4
    • 0033928341 scopus 로고    scopus 로고
    • Complications of thyroid surgery: How to avoid them, how to manage them, and observations on their possible effect on the whole patient
    • Reeve T, Thompson NW. Complications of thyroid surgery: how to avoid them, how to manage them, and observations on their possible effect on the whole patient. World J Surg 2000; 24: 971-975.
    • (2000) World J Surg , vol.24 , pp. 971-975
    • Reeve, T.1    Thompson, N.W.2
  • 5
    • 0033042428 scopus 로고    scopus 로고
    • Experimental study on heat production by a 23.5-kHz ultrasonically activated device for endoscopic surgery
    • Kinoshita T, Kanehira E, Omura K, Kawakami K, Watanabe Y. Experimental study on heat production by a 23.5-kHz ultrasonically activated device for endoscopic surgery. Surg Endosc 1999; 13: 621-625.
    • (1999) Surg Endosc , vol.13 , pp. 621-625
    • Kinoshita, T.1    Kanehira, E.2    Omura, K.3    Kawakami, K.4    Watanabe, Y.5
  • 6
    • 0032951086 scopus 로고    scopus 로고
    • Acute thermal injury to the canine jejunal free flap: Electrocautery versus ultrasonic dissection
    • Birch DW, Park A, Shuhaibar H. Acute thermal injury to the canine jejunal free flap: electrocautery versus ultrasonic dissection. Am Surg 1999; 65: 334-337.
    • (1999) Am Surg , vol.65 , pp. 334-337
    • Birch, D.W.1    Park, A.2    Shuhaibar, H.3
  • 7
    • 0028213002 scopus 로고
    • The experimental development of an ultrasonically activated scalpel for laparoscopic use
    • Amaral JF. The experimental development of an ultrasonically activated scalpel for laparoscopic use. Surg Laparosc Endosc 1994; 4: 92-99.
    • (1994) Surg Laparosc Endosc , vol.4 , pp. 92-99
    • Amaral, J.F.1
  • 9
    • 0036289566 scopus 로고    scopus 로고
    • The ultrasonic coagulating and cutting system injures nerve function
    • Owaki T, Nakano S, Arimura K, Aikou T. The ultrasonic coagulating and cutting system injures nerve function. Endoscopy 2002; 34: 575-579.
    • (2002) Endoscopy , vol.34 , pp. 575-579
    • Owaki, T.1    Nakano, S.2    Arimura, K.3    Aikou, T.4
  • 10
    • 0036959076 scopus 로고    scopus 로고
    • Technology and clinical application of ultrasonic dissection
    • Feil W. Technology and clinical application of ultrasonic dissection. Min Invas Ther Allied Technol 2002; 11: 215-223.
    • (2002) Min Invas Ther Allied Technol , vol.11 , pp. 215-223
    • Feil, W.1
  • 11
    • 0012680256 scopus 로고    scopus 로고
    • Schilddrüsen resection mit ultracision
    • Feil W. Schilddrüsen resection mit Ultracision. Acta Chirurgica Austriaca 1997; Suppl. 130: 23.
    • (1997) Acta Chirurgica Austriaca , Issue.SUPPL. 130 , pp. 23
    • Feil, W.1
  • 12
    • 0001035243 scopus 로고
    • Depth of thermal injury: Ultrasonically activated scalpel vs electrosurgery
    • Amaral JF. Depth of thermal injury: ultrasonically activated scalpel vs electrosurgery. Surg Endosc 1995; 9: 226-231.
    • (1995) Surg Endosc , vol.9 , pp. 226-231
    • Amaral, J.F.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.