메뉴 건너뛰기




Volumn 29, Issue 3, 2008, Pages 410-416

Hemorrhage progressively disturbs interalveolar perfusion in the lungs of rats

Author keywords

Dispersion index analysis; Microvascular perfusion; Perfusion distribution; Pulmonary circulation

Indexed keywords

ARTERIAL GAS; ARTICLE; BLOOD FLOW; BLOOD PRESSURE; BLOOD VOLUME; CONFOCAL MICROSCOPY; CONTROLLED STUDY; LUNG HEMORRHAGE; LUNG INJURY; LUNG PERFUSION; NONHUMAN; RAT; SYSTEMIC CIRCULATION;

EID: 39449120274     PISSN: 10732322     EISSN: None     Source Type: Journal    
DOI: 10.1097/SHK.0b013e318145a342     Document Type: Article
Times cited : (8)

References (19)
  • 1
    • 0020519323 scopus 로고
    • Ventilation-perfusion relationships during hemorrhagic hypotension and reinfusion in the dog
    • Fortune JB, Mazzone RW, Wagner PD: Ventilation-perfusion relationships during hemorrhagic hypotension and reinfusion in the dog. J Appl Physiol 54:1071-1082, 1983.
    • (1983) J Appl Physiol , vol.54 , pp. 1071-1082
    • Fortune, J.B.1    Mazzone, R.W.2    Wagner, P.D.3
  • 2
    • 33646090172 scopus 로고    scopus 로고
    • Hemorrhage causes inter-alveolar perfusion mal-distribution in the lungs of anesthetized rats
    • Conhaim RL, Heisey DM, Leverson GE, Watson KE, Harms BA: Hemorrhage causes inter-alveolar perfusion mal-distribution in the lungs of anesthetized rats. J Trauma 60:158-160, 2006.
    • (2006) J Trauma , vol.60 , pp. 158-160
    • Conhaim, R.L.1    Heisey, D.M.2    Leverson, G.E.3    Watson, K.E.4    Harms, B.A.5
  • 3
    • 0037310101 scopus 로고    scopus 로고
    • Perfusion heterogeneity in rat lungs assessed from the distribution of 4-μm diameter latex particles
    • Conhaim RL, Heisey DM, Leverson GE, Watson KE, Harms BA: Perfusion heterogeneity in rat lungs assessed from the distribution of 4-μm diameter latex particles. J Applied Physiol 94:420-428, 2003.
    • (2003) J Applied Physiol , vol.94 , pp. 420-428
    • Conhaim, R.L.1    Heisey, D.M.2    Leverson, G.E.3    Watson, K.E.4    Harms, B.A.5
  • 4
    • 0026023118 scopus 로고
    • Hemodynamic and neurohumoral responses to acute hypovolemia in conscious animals
    • Schadt JC, Ludbrook J: Hemodynamic and neurohumoral responses to acute hypovolemia in conscious animals. Am J Physiol 260:H305-H318, 1991.
    • (1991) Am J Physiol , vol.260
    • Schadt, J.C.1    Ludbrook, J.2
  • 6
    • 0031829353 scopus 로고    scopus 로고
    • Functional diameters of alveolar microvessels at high lung volume in zone II
    • Conhaim RL, Rodenkirch LA: Functional diameters of alveolar microvessels at high lung volume in zone II. J Appl Physiol 85:47-52, 1998.
    • (1998) J Appl Physiol , vol.85 , pp. 47-52
    • Conhaim, R.L.1    Rodenkirch, L.A.2
  • 7
    • 39449108926 scopus 로고    scopus 로고
    • Bethesda, Maryland, USA
    • Rasband WS: ImageJ, US National Institutes of Health, Bethesda, Maryland, USA, http://rsb.info.nih.gov/ij, 1997-2007.
    • (1997)
    • Rasband, W.S.1    ImageJ, U.S.2
  • 9
    • 0343103945 scopus 로고
    • The use of random and contiguous quadrants in the study of the structure of plant communities
    • Grieg-Smith P: The use of random and contiguous quadrants in the study of the structure of plant communities. Ann Bot (Lond) 16:293-316, 1952.
    • (1952) Ann Bot (Lond) , vol.16 , pp. 293-316
    • Grieg-Smith, P.1
  • 10
    • 0002715524 scopus 로고
    • Comparative quantitative morphology of the mammalian lung: Diffusing area
    • Tenney SM, Remmers JE: Comparative quantitative morphology of the mammalian lung: diffusing area. Nature 197:54-56, 1963.
    • (1963) Nature , vol.197 , pp. 54-56
    • Tenney, S.M.1    Remmers, J.E.2
  • 12
    • 0347363485 scopus 로고    scopus 로고
    • Thromboxane receptor analog, U46619, redistributes pulmonary microvascular perfusion in isolated rat lungs
    • Conhaim RL, Heisey DM, Leverson GE, Watson KE, Harms BA: Thromboxane receptor analog, U46619, redistributes pulmonary microvascular perfusion in isolated rat lungs. J Applied Physiol 96:245-252, 2004.
    • (2004) J Applied Physiol , vol.96 , pp. 245-252
    • Conhaim, R.L.1    Heisey, D.M.2    Leverson, G.E.3    Watson, K.E.4    Harms, B.A.5
  • 13
    • 33748602905 scopus 로고    scopus 로고
    • Antithrombin is as effective as heparin and hirudin to prevent formation of microvascular thrombosis in a murine model
    • Sorg H, Hoffman JN, Menger MD, Lindenblatt N, Goehring P, Vollmar B: Antithrombin is as effective as heparin and hirudin to prevent formation of microvascular thrombosis in a murine model. Thromb Haemost 96:371-377, 2006.
    • (2006) Thromb Haemost , vol.96 , pp. 371-377
    • Sorg, H.1    Hoffman, J.N.2    Menger, M.D.3    Lindenblatt, N.4    Goehring, P.5    Vollmar, B.6
  • 14
    • 0346076096 scopus 로고
    • The granulocytopenic response in hemorrhagic shock
    • Schweinburg FB, Smiddy FG, Fine J: The granulocytopenic response in hemorrhagic shock. J Clin Invest 38:673-680, 1959.
    • (1959) J Clin Invest , vol.38 , pp. 673-680
    • Schweinburg, F.B.1    Smiddy, F.G.2    Fine, J.3
  • 15
    • 0029181208 scopus 로고
    • Leukocyte margination during hemorrhage shock correlates to preshock margination and is reduced by fucoidin
    • Wikstrom T, Braide M, Bagge U, Risberg B: Leukocyte margination during hemorrhage shock correlates to preshock margination and is reduced by fucoidin. Shock 3:40-45, 1995.
    • (1995) Shock , vol.3 , pp. 40-45
    • Wikstrom, T.1    Braide, M.2    Bagge, U.3    Risberg, B.4
  • 16
    • 0035655120 scopus 로고    scopus 로고
    • Differential cardiopulmonary recruitment of neutrophils during hemorrhagic shock: A role for ICAM-1?
    • Song Y, Ao L, Calkins CM, Raeburn CD, Harken AH, Meng X: Differential cardiopulmonary recruitment of neutrophils during hemorrhagic shock: a role for ICAM-1? Shock 16:444-448, 2001.
    • (2001) Shock , vol.16 , pp. 444-448
    • Song, Y.1    Ao, L.2    Calkins, C.M.3    Raeburn, C.D.4    Harken, A.H.5    Meng, X.6
  • 17
    • 0017836440 scopus 로고
    • The effect of continued hypoxia on rat pulmonary arterial circulation - an ultrastructural study
    • Meyrick B, Reid L: The effect of continued hypoxia on rat pulmonary arterial circulation - an ultrastructural study. Lab Invest 38:188-200, 1978.
    • (1978) Lab Invest , vol.38 , pp. 188-200
    • Meyrick, B.1    Reid, L.2
  • 18
    • 0025144428 scopus 로고
    • Fractal properties of pulmonary blood flow: Characterization of spatial heterogeneity
    • Glenny RW, Robertson HT: Fractal properties of pulmonary blood flow: characterization of spatial heterogeneity. J Appl Physiol 69:532-545, 1990.
    • (1990) J Appl Physiol , vol.69 , pp. 532-545
    • Glenny, R.W.1    Robertson, H.T.2
  • 19
    • 0033870304 scopus 로고    scopus 로고
    • Pulmonary blood flow remains fractal down to the level of gas exchange
    • Glenny RW, Bernard SL, Robertson HT: Pulmonary blood flow remains fractal down to the level of gas exchange. J Appl Physiol 89:742-748, 2000.
    • (2000) J Appl Physiol , vol.89 , pp. 742-748
    • Glenny, R.W.1    Bernard, S.L.2    Robertson, H.T.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.