메뉴 건너뛰기




Volumn 32, Issue 3, 2008, Pages 210-220

Studies on circular isocentric cone-beam trajectories for 3D image reconstructions using FDK algorithm

Author keywords

3D image reconstruction; Computed tomography (CT); Cone beam CT; Feldkamp type reconstruction

Indexed keywords

COMPUTERIZED TOMOGRAPHY; ERROR ANALYSIS; IMAGE QUALITY; LASER BEAMS; SCANNING; THREE DIMENSIONAL;

EID: 39249083485     PISSN: 08956111     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.compmedimag.2007.12.005     Document Type: Article
Times cited : (10)

References (15)
  • 2
    • 2442661205 scopus 로고    scopus 로고
    • An improved exact filtered backprojection algorithm for spiral CT
    • Katsevich A. An improved exact filtered backprojection algorithm for spiral CT. Adv Appl Math 32 4 (2004) 681-697
    • (2004) Adv Appl Math , vol.32 , Issue.4 , pp. 681-697
    • Katsevich, A.1
  • 3
    • 1642569142 scopus 로고    scopus 로고
    • Exact image reconstruction on PI-lines from minimum data in helical cone-beam CT
    • Zou Y., and Pan X. Exact image reconstruction on PI-lines from minimum data in helical cone-beam CT. Phys Med Biol 49 (2004) 941-959
    • (2004) Phys Med Biol , vol.49 , pp. 941-959
    • Zou, Y.1    Pan, X.2
  • 4
    • 11244340844 scopus 로고    scopus 로고
    • An error-reduction-based algorithm for cone-beam computed tomography
    • Zeng K., Chen Z., Zhang L., and Wang G. An error-reduction-based algorithm for cone-beam computed tomography. Med Phys 31 12 (2004) 3206-3212
    • (2004) Med Phys , vol.31 , Issue.12 , pp. 3206-3212
    • Zeng, K.1    Chen, Z.2    Zhang, L.3    Wang, G.4
  • 5
    • 23744435329 scopus 로고    scopus 로고
    • A three-dimensional weighted cone beam filtered backprojection (CB-FBP) algorithm for image reconstruction in volumetric CT under a circular source trajectory
    • Tang X., Hsieh J., Hagiwara A., Nilsen R.A., Thibault J.B., and Drapkin E. A three-dimensional weighted cone beam filtered backprojection (CB-FBP) algorithm for image reconstruction in volumetric CT under a circular source trajectory. Phys Med Biol 50 (2005) 3889-3905
    • (2005) Phys Med Biol , vol.50 , pp. 3889-3905
    • Tang, X.1    Hsieh, J.2    Hagiwara, A.3    Nilsen, R.A.4    Thibault, J.B.5    Drapkin, E.6
  • 6
    • 0042903710 scopus 로고    scopus 로고
    • A general scheme for constructing in inversion algorithms for cone-beam CT
    • Katsevich A. A general scheme for constructing in inversion algorithms for cone-beam CT. Int J Math Math Sci 21 (2003) 1305-1321
    • (2003) Int J Math Math Sci , vol.21 , pp. 1305-1321
    • Katsevich, A.1
  • 7
    • 20044372762 scopus 로고    scopus 로고
    • Image reconstruction for the circle-and-arc trajectory
    • Katsevich A. Image reconstruction for the circle-and-arc trajectory. Phys Med Biol 50 (2005) 2249-2265
    • (2005) Phys Med Biol , vol.50 , pp. 2249-2265
    • Katsevich, A.1
  • 8
    • 0020764170 scopus 로고
    • An inversion formula for cone-beam reconstructions
    • Tuy H.K. An inversion formula for cone-beam reconstructions. SIAM J Appl Math 43 3 (1983) 546-552
    • (1983) SIAM J Appl Math , vol.43 , Issue.3 , pp. 546-552
    • Tuy, H.K.1
  • 10
    • 0032596664 scopus 로고    scopus 로고
    • Image quality and accuracy in x-ray microtomography
    • Davis G.R. Image quality and accuracy in x-ray microtomography. Proc SPIE 3772 (1999) 147-155
    • (1999) Proc SPIE , vol.3772 , pp. 147-155
    • Davis, G.R.1
  • 11
    • 39249083451 scopus 로고    scopus 로고
    • National Library of Medicine's 'Visible Human Project®', http://www.nlm.nih.gov/research/visible.
    • National Library of Medicine's 'Visible Human Project®', http://www.nlm.nih.gov/research/visible.
  • 12
    • 0033624786 scopus 로고    scopus 로고
    • A software data generator for radiographic imaging investigations
    • Lazos D., Kolitsi Z., and Pallikarakis N. A software data generator for radiographic imaging investigations. IEEE Trans Inf Biomed 4 (2000) 76-79
    • (2000) IEEE Trans Inf Biomed , vol.4 , pp. 76-79
    • Lazos, D.1    Kolitsi, Z.2    Pallikarakis, N.3
  • 13
    • 39249083039 scopus 로고    scopus 로고
    • Bliznakova K. 'Study and development of software simulation for X-ray imaging', Ph.D. dissertation, Dept. Medical Physics, Patras University, Greece, 2003.
    • Bliznakova K. 'Study and development of software simulation for X-ray imaging', Ph.D. dissertation, Dept. Medical Physics, Patras University, Greece, 2003.
  • 14
    • 0037262197 scopus 로고    scopus 로고
    • A novel approach for distortion correction for X-ray image intensifiers
    • Soimu D., Badea C., and Pallikarakis N. A novel approach for distortion correction for X-ray image intensifiers. Comput Med Imaging Graph 27 1 (2003) 79-85
    • (2003) Comput Med Imaging Graph , vol.27 , Issue.1 , pp. 79-85
    • Soimu, D.1    Badea, C.2    Pallikarakis, N.3
  • 15
    • 0035263545 scopus 로고    scopus 로고
    • Image quality in extended arc filtered digital tomosynthesis
    • Badea C., Kolitsi Z., and Pallikarakis N. Image quality in extended arc filtered digital tomosynthesis. Acta Radiologica 42 (2001) 244-249
    • (2001) Acta Radiologica , vol.42 , pp. 244-249
    • Badea, C.1    Kolitsi, Z.2    Pallikarakis, N.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.