메뉴 건너뛰기




Volumn 4, Issue 1, 2000, Pages 76-79

A software data generator for radiographic imaging investigations

Author keywords

Digital tomosynthesis; Medical imaging; Simulation

Indexed keywords

COMPUTATIONAL GEOMETRY; COMPUTER AIDED SOFTWARE ENGINEERING; COMPUTER SIMULATION; COMPUTERIZED TOMOGRAPHY; MEDICAL IMAGING;

EID: 0033624786     PISSN: 10897771     EISSN: None     Source Type: Journal    
DOI: 10.1109/4233.826863     Document Type: Article
Times cited : (33)

References (16)
  • 1
    • 0028393103 scopus 로고    scopus 로고
    • "A Monte Carlo program for the calculation of contrast, noise and absorbed dose in diagnostic radiology,"
    • vol. 42, pp. 167-180, 1994.
    • M. Sandborg, D. R. Dance, J. Persliden, and G. A. Carlsson, "A Monte Carlo program for the calculation of contrast, noise and absorbed dose in diagnostic radiology," Comput. Methods Prog. Biomed., vol. 42, pp. 167-180, 1994.
    • Comput. Methods Prog. Biomed.
    • Sandborg, M.1    Dance, D.R.2    Persliden, J.3    Carlsson, G.A.4
  • 2
    • 0027283787 scopus 로고    scopus 로고
    • "A new composite model of objects for Monte Carlo simulation of radiological imaging,"
    • vol. 38, pp. 1235-1262, 1993.
    • H. Wang, R. J. Jaczszak, and R. E. Coleman, "A new composite model of objects for Monte Carlo simulation of radiological imaging," Phys. Med. Biol., vol. 38, pp. 1235-1262, 1993.
    • Phys. Med. Biol.
    • Wang, H.1    Jaczszak, R.J.2    Coleman, R.E.3
  • 3
    • 0028903253 scopus 로고    scopus 로고
    • "Evaluation of image quality in fluoroscopy by measurements and Monte Carlo calculations,"
    • vol. 40, pp. 589-607, 1995.
    • M. J. Tapiovaara and M. Sandborg, "Evaluation of image quality in fluoroscopy by measurements and Monte Carlo calculations," Phys. Med. Biol., vol. 40, pp. 589-607, 1995.
    • Phys. Med. Biol.
    • Tapiovaara, M.J.1    Sandborg, M.2
  • 4
    • 0021906794 scopus 로고    scopus 로고
    • "Physical characteristics of the scattered radiation in diagnostic radiology: Monte Carlo simulation studies,"
    • vol. 12, pp. 152-165, 1985.
    • H. P. Chan and K. Doi, "Physical characteristics of the scattered radiation in diagnostic radiology: Monte Carlo simulation studies," Med. Phys., vol. 12, pp. 152-165, 1985.
    • Med. Phys.
    • Chan, H.P.1    Doi, K.2
  • 5
    • 0023948897 scopus 로고    scopus 로고
    • "Computer simulation of image intensifier-based computed tomography detector: Vascular application,"
    • vol. 15, no. 2, pp. 188-192, 1988.
    • R. Ning and R. A. Kruger, "Computer simulation of image intensifier-based computed tomography detector: Vascular application," Med. Phys., vol. 15, no. 2, pp. 188-192, 1988.
    • Med. Phys.
    • Ning, R.1    Kruger, R.A.2
  • 6
    • 0020213666 scopus 로고    scopus 로고
    • "Photon mass attenuation and energy absorption coefficients from 1 keV to 20 MeV,"
    • vol. 33, p. 1269, 1982.
    • J. H. Hubbell, "Photon mass attenuation and energy absorption coefficients from 1 keV to 20 MeV," Int. J. Appl. Radiât. Isotopes, vol. 33, p. 1269, 1982.
    • Int. J. Appl. Radiât. Isotopes
    • Hubbell, J.H.1
  • 9
    • 0022897326 scopus 로고    scopus 로고
    • "Three improvements of the ray tracing algorithm for CSG trees,"
    • vol. 10, pp. 333-339, 1986.
    • M. Gervautz, "Three improvements of the ray tracing algorithm for CSG trees," Comput. Graph., vol. 10, pp. 333-339, 1986.
    • Comput. Graph.
    • Gervautz, M.1
  • 10
    • 0021952059 scopus 로고    scopus 로고
    • "Fast calculation of the exact radiological path for the three-dimensional CT array,"
    • vol. 12, no. 2, pp. 252-255, 1985.
    • R. Siddon, "Fast calculation of the exact radiological path for the three-dimensional CT array," Med. Phys., vol. 12, no. 2, pp. 252-255, 1985.
    • Med. Phys.
    • Siddon, R.1
  • 11
    • 0025756532 scopus 로고    scopus 로고
    • "Semiempirical model for generating tungsten target X-ray spectra,"
    • vol. 18, no. 2, pp. 211-218, 1991.
    • D. M. Tucker, G. T. Barnes, and D. P. Chakraborty, "Semiempirical model for generating tungsten target X-ray spectra," Med. Phys., vol. 18, no. 2, pp. 211-218, 1991.
    • Med. Phys.
    • Tucker, D.M.1    Barnes, G.T.2    Chakraborty, D.P.3
  • 12
    • 0025759912 scopus 로고    scopus 로고
    • "Molybdenum target X-ray spectra: A semiempirical model,"
    • vol. 18, no. 3, pp. 402-407, 1991.
    • D. M. Tucker, G. T. Barnes, and X. Wu, "Molybdenum target X-ray spectra: A semiempirical model," Med. Phys., vol. 18, no. 3, pp. 402-407, 1991.
    • Med. Phys.
    • Tucker, D.M.1    Barnes, G.T.2    Wu, X.3
  • 14
    • 0027395004 scopus 로고    scopus 로고
    • "A method for selective removal of out-of-plane structures in digital tomosynthesis,"
    • vol. 20, no. 1, pp. 47-50, 1993.
    • Z. Kolitsi, G. Panayiotakis, and N. Pallikarakis, "A method for selective removal of out-of-plane structures in digital tomosynthesis," Med. Phys., vol. 20, no. 1, pp. 47-50, 1993.
    • Med. Phys.
    • Kolitsi, Z.1    Panayiotakis, G.2    Pallikarakis, N.3
  • 15
    • 0032124969 scopus 로고    scopus 로고
    • "A wavelet based method for removal of out-of-plane structures in digital tomosynthesis,"
    • vol. 22, pp. 309-317, 1998.
    • C. Badea, Z. Kolitsi, and N. Pallikarakis, "A wavelet based method for removal of out-of-plane structures in digital tomosynthesis," Comput. Med. Imaging Graphics, vol. 22, pp. 309-317, 1998.
    • Comput. Med. Imaging Graphics
    • Badea, C.1    Kolitsi, Z.2    Pallikarakis, N.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.