메뉴 건너뛰기




Volumn 18, Issue 1, 2008, Pages 158-167

Magnetic resonance angiographic assessment of upper extremity vessels prior to vascular access surgery: Feasibility and accuracy

Author keywords

Contrast enhanced magnetic resonance angiography; Duplexultra sound; Hemodialysis; Vascular access

Indexed keywords

GADOLINIUM PENTETATE;

EID: 38949093810     PISSN: 09387994     EISSN: None     Source Type: Journal    
DOI: 10.1007/s00330-007-0714-y     Document Type: Article
Times cited : (13)

References (52)
  • 1
    • 27944497842 scopus 로고    scopus 로고
    • ESRD patients in 2004: Global overview of patient numbers, treatment modalities and associated trends
    • Grassmann A, Gioberge S, Moeller S, Brown G (2005) ESRD patients in 2004: Global overview of patient numbers, treatment modalities and associated trends. Nephrol Dial Transplant 20:2587-2593
    • (2005) Nephrol Dial Transplant , vol.20 , pp. 2587-2593
    • Grassmann, A.1    Gioberge, S.2    Moeller, S.3    Brown, G.4
  • 4
    • 0035228229 scopus 로고    scopus 로고
    • Clinical practice guidelines for vascular access: Update 2000
    • NKF-K/DOQI
    • NKF-K/DOQI (2001) Clinical practice guidelines for vascular access: update 2000. Am J Kidney Dis 37(Suppl 1):S137-S181
    • (2001) Am J Kidney Dis , vol.37 , Issue.SUPPL.1
  • 5
    • 0043195731 scopus 로고    scopus 로고
    • European guidelines for vascular access: Clinical algorithms on vascular access for haemodialysis
    • Tordoir JH, Mickley V (2003) European guidelines for vascular access: clinical algorithms on vascular access for haemodialysis. Edtna Erca J 29:131-136
    • (2003) Edtna Erca J , vol.29 , pp. 131-136
    • Tordoir, J.H.1    Mickley, V.2
  • 7
    • 0036268326 scopus 로고    scopus 로고
    • Native arteriovenous fistula: Preoperative evaluation
    • Malovrh M (2002) Native arteriovenous fistula: Preoperative evaluation. Am J Kidney Dis 39:1218-1225
    • (2002) Am J Kidney Dis , vol.39 , pp. 1218-1225
    • Malovrh, M.1
  • 8
    • 0031962966 scopus 로고    scopus 로고
    • Non-invasive evaluation of vessels by duplex sonography prior to construction of arteriovenous fistulas for haemodialysis
    • Malovrh M (1998) Non-invasive evaluation of vessels by duplex sonography prior to construction of arteriovenous fistulas for haemodialysis. Nephrol Dial Transplant 13:125-129
    • (1998) Nephrol Dial Transplant , vol.13 , pp. 125-129
    • Malovrh, M.1
  • 10
    • 0031801969 scopus 로고    scopus 로고
    • Does pre-operative duplex examination improve patency rates of Brescia-Cimino fistulas?
    • Lemson MS, Leunissen KM, Tordoir JH (1998) Does pre-operative duplex examination improve patency rates of Brescia-Cimino fistulas? Nephrol Dial Transplant 13:1360-1361
    • (1998) Nephrol Dial Transplant , vol.13 , pp. 1360-1361
    • Lemson, M.S.1    Leunissen, K.M.2    Tordoir, J.H.3
  • 11
    • 0042744078 scopus 로고    scopus 로고
    • Native arterio-venous fistula for hemodialysis: What to expect early after creation?
    • Leblanc M, Saint-Sauveur E, Pichette V (2003) Native arterio-venous fistula for hemodialysis: What to expect early after creation? J Vasc Access 4:39-44
    • (2003) J Vasc Access , vol.4 , pp. 39-44
    • Leblanc, M.1    Saint-Sauveur, E.2    Pichette, V.3
  • 12
    • 0036733265 scopus 로고    scopus 로고
    • Prediction of wrist arteriovenous fistula maturation with preoperative vein mapping with ultrasonography
    • Mendes RR, Farber MA, Marston WA, Dinwiddie LC, Keagy BA, Burnham SJ (2002) Prediction of wrist arteriovenous fistula maturation with preoperative vein mapping with ultrasonography. J Vasc Surg 36:460-463
    • (2002) J Vasc Surg , vol.36 , pp. 460-463
    • Mendes, R.R.1    Farber, M.A.2    Marston, W.A.3    Dinwiddie, L.C.4    Keagy, B.A.5    Burnham, S.J.6
  • 15
    • 0036023013 scopus 로고    scopus 로고
    • Utility of ultrasonographic venous assessment prior to forearm arteriovenous fistula creation
    • Brimble KS, Rabbat ChG, Treleaven DJ, Ingram AJ (2002) Utility of ultrasonographic venous assessment prior to forearm arteriovenous fistula creation. Clin Nephrol 58:122-127
    • (2002) Clin Nephrol , vol.58 , pp. 122-127
    • Brimble, K.S.1    Rabbat, Ch.G.2    Treleaven, D.J.3    Ingram, A.J.4
  • 16
    • 0033984858 scopus 로고    scopus 로고
    • Changes in the practice of angioaccess surgery: Impact of dialysis outcome and quality initiative recommendations
    • Ascher E, Gade P, Hingorani A, Mazzariol F, Gunduz Y, Fodera M, Yorkovich W (2000) Changes in the practice of angioaccess surgery: impact of dialysis outcome and quality initiative recommendations. J Vasc Surg 31:84-92
    • (2000) J Vasc Surg , vol.31 , pp. 84-92
    • Ascher, E.1    Gade, P.2    Hingorani, A.3    Mazzariol, F.4    Gunduz, Y.5    Fodera, M.6    Yorkovich, W.7
  • 17
    • 0141724578 scopus 로고    scopus 로고
    • Failure of arteriovenous fistula maturation: An unintended consequence of exceeding dialysis outcome quality Initiative guidelines for hemodialysis access
    • discussion 445
    • Patel ST, Hughes J, Mills JL Sr (2003) Failure of arteriovenous fistula maturation: An unintended consequence of exceeding dialysis outcome quality Initiative guidelines for hemodialysis access. J Vasc Surg 38:439-445; discussion 445
    • (2003) J Vasc Surg , vol.38 , pp. 439-445
    • Patel, S.T.1    Hughes, J.2    Mills Sr., J.L.3
  • 18
    • 1042266594 scopus 로고    scopus 로고
    • Preoperative sonographic radial artery evaluation and correlation with subsequent radiocephalic fistula outcome
    • quiz 169-171
    • Lockhart ME, Robbin ML, Allon M (2004) Preoperative sonographic radial artery evaluation and correlation with subsequent radiocephalic fistula outcome. J Ultrasound Med 23:161-168; quiz 169-171
    • (2004) J Ultrasound Med , vol.23 , pp. 161-168
    • Lockhart, M.E.1    Robbin, M.L.2    Allon, M.3
  • 22
    • 0036379571 scopus 로고    scopus 로고
    • Increasing arteriovenous fistulas in hemodialysis patients: Problems and solutions
    • Allon M, Robbin ML (2002) Increasing arteriovenous fistulas in hemodialysis patients: Problems and solutions. Kidney Int 62:1109-1124
    • (2002) Kidney Int , vol.62 , pp. 1109-1124
    • Allon, M.1    Robbin, M.L.2
  • 23
    • 0000966690 scopus 로고    scopus 로고
    • Patient selection with preoperative duplex examination can improve patnecy rates of brescia-cimino fistulas
    • Lemson MS, Zwiers I, Leunissen KML, Tordoir JHM (1999) Patient selection with preoperative duplex examination can improve patnecy rates of brescia-cimino fistulas. J Vasc Technol 23:115-119
    • (1999) J Vasc Technol , vol.23 , pp. 115-119
    • Lemson, M.S.1    Zwiers, I.2    Leunissen, K.M.L.3    Tordoir, J.H.M.4
  • 24
    • 0031784731 scopus 로고    scopus 로고
    • Limits to the accuracy of vessel diameter measurement in MR angiography
    • Hoogeveen RM, Bakker CJ, Viergever MA (1998) Limits to the accuracy of vessel diameter measurement in MR angiography. J Magn Reson Imaging 8:1228-1235
    • (1998) J Magn Reson Imaging , vol.8 , pp. 1228-1235
    • Hoogeveen, R.M.1    Bakker, C.J.2    Viergever, M.A.3
  • 28
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • Bland JM, Altman DG (1986) Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1:307-310
    • (1986) Lancet , vol.1 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 30
    • 11144238401 scopus 로고    scopus 로고
    • Noninvasive detection of steno-occlusive disease of the supra-aortic arteries with three-dimensional contrast-enhanced magnetic resonance angiography: A prospective, intra-individual comparative analysis with digital subtraction angiography
    • Willinek WA, von Falkenhausen M, Born M, Gieseke J, Holler T, Klockgether T, Textor HJ, Schild HH, Urbach H (2005) Noninvasive detection of steno-occlusive disease of the supra-aortic arteries with three-dimensional contrast-enhanced magnetic resonance angiography: A prospective, intra-individual comparative analysis with digital subtraction angiography. Stroke 36:38-43
    • (2005) Stroke , vol.36 , pp. 38-43
    • Willinek, W.A.1    von Falkenhausen, M.2    Born, M.3    Gieseke, J.4    Holler, T.5    Klockgether, T.6    Textor, H.J.7    Schild, H.H.8    Urbach, H.9
  • 32
    • 0034111614 scopus 로고    scopus 로고
    • Pelvic and lower extremity veins: Contrast-enhanced three-dimensional MR venography with a dedicated vascular coil-initial experience
    • Ruehm SG, Wiesner W, Debatin JF (2000) Pelvic and lower extremity veins: contrast-enhanced three-dimensional MR venography with a dedicated vascular coil-initial experience. Radiology 215:421-427
    • (2000) Radiology , vol.215 , pp. 421-427
    • Ruehm, S.G.1    Wiesner, W.2    Debatin, J.F.3
  • 33
    • 0034879766 scopus 로고    scopus 로고
    • Direct contrast-enhanced 3D MR venography
    • Ruehm SG, Zimny K, Debatin JF (2001) Direct contrast-enhanced 3D MR venography. Eur Radiol 11:102-112
    • (2001) Eur Radiol , vol.11 , pp. 102-112
    • Ruehm, S.G.1    Zimny, K.2    Debatin, J.F.3
  • 34
    • 0037742404 scopus 로고    scopus 로고
    • MR venography
    • Ruehm SG (2003) MR venography. Eur Radiol 13:229-230
    • (2003) Eur Radiol , vol.13 , pp. 229-230
    • Ruehm, S.G.1
  • 35
    • 0031906540 scopus 로고    scopus 로고
    • Aortic and lower-extremity arterial disease: Evaluation with MR angiography versus conventional angiography
    • Quinn SF, Sheley RC, Semonsen KG, Leonardo VJ, Kojima K, Szumowski J (1998) Aortic and lower-extremity arterial disease: Evaluation with MR angiography versus conventional angiography. Radiology 206:693-701
    • (1998) Radiology , vol.206 , pp. 693-701
    • Quinn, S.F.1    Sheley, R.C.2    Semonsen, K.G.3    Leonardo, V.J.4    Kojima, K.5    Szumowski, J.6
  • 39
    • 0035161445 scopus 로고    scopus 로고
    • Three-dimensional gadolinium-enhanced magnetic resonance venography in suspected thrombo-occlusive disease of the central chest veins
    • Kroencke TJ, Taupitz M, Arnold R, Fritsche L, Hamm B (2001) Three-dimensional gadolinium-enhanced magnetic resonance venography in suspected thrombo-occlusive disease of the central chest veins. Chest 120:1570-1576
    • (2001) Chest , vol.120 , pp. 1570-1576
    • Kroencke, T.J.1    Taupitz, M.2    Arnold, R.3    Fritsche, L.4    Hamm, B.5
  • 41
    • 0037417499 scopus 로고    scopus 로고
    • High-resolution magnetic resonance angiography of hands with timed arterial compression (tac-MRA)
    • Wentz KU, Frohlich JM, von Weymarn C, Patak MA, Jenelten R, Zollikofer CL (2003) High-resolution magnetic resonance angiography of hands with timed arterial compression (tac-MRA). Lancet 361:49-50
    • (2003) Lancet , vol.361 , pp. 49-50
    • Wentz, K.U.1    Frohlich, J.M.2    von Weymarn, C.3    Patak, M.A.4    Jenelten, R.5    Zollikofer, C.L.6
  • 42
    • 0025906318 scopus 로고
    • Limitations of magnetic resonance imaging and ultrasound-directed (duplex) scanning in the diagnosis of subclavian vein thrombosis
    • Haire WD, Lynch TG, Lund GB, Lieberman RP, Edney JA (1991) Limitations of magnetic resonance imaging and ultrasound-directed (duplex) scanning in the diagnosis of subclavian vein thrombosis. J Vasc Surg 13:391-397
    • (1991) J Vasc Surg , vol.13 , pp. 391-397
    • Haire, W.D.1    Lynch, T.G.2    Lund, G.B.3    Lieberman, R.P.4    Edney, J.A.5
  • 43
    • 0032988869 scopus 로고    scopus 로고
    • Magnetic resonance imaging of the aorta and branch vessels
    • Ho VB, Prince MR, Dong Q (1999) Magnetic resonance imaging of the aorta and branch vessels. Coron Artery Dis 10:141-149
    • (1999) Coron Artery Dis , vol.10 , pp. 141-149
    • Ho, V.B.1    Prince, M.R.2    Dong, Q.3
  • 45
  • 47
    • 0032737423 scopus 로고    scopus 로고
    • Three-dimensional gadolinium-enhanced MR venographic evaluation of patency of central veins in the thorax: Initial experience
    • Shinde TS, Lee VS, Rofsky NM, Krinsky GA, Weinreb JC (1999) Three-dimensional gadolinium-enhanced MR venographic evaluation of patency of central veins in the thorax: Initial experience. Radiology 213:555-560
    • (1999) Radiology , vol.213 , pp. 555-560
    • Shinde, T.S.1    Lee, V.S.2    Rofsky, N.M.3    Krinsky, G.A.4    Weinreb, J.C.5
  • 48
    • 2942744595 scopus 로고    scopus 로고
    • MR venography needs to know where it stands for vascular mapping prior to fistula creation
    • Mihmanli I, Kantarci F (2004) MR venography needs to know where it stands for vascular mapping prior to fistula creation. Eur Radiol 14:1130-1131
    • (2004) Eur Radiol , vol.14 , pp. 1130-1131
    • Mihmanli, I.1    Kantarci, F.2
  • 49
    • 0037743429 scopus 로고    scopus 로고
    • Magnetic resonance angiography of the peripheral arteries: Current status
    • Meaney JF (2003) Magnetic resonance angiography of the peripheral arteries: Current status. Eur Radiol 13:836-852
    • (2003) Eur Radiol , vol.13 , pp. 836-852
    • Meaney, J.F.1
  • 51
    • 33847181326 scopus 로고    scopus 로고
    • Nephrogenic systemic fibrosis: A serious late adverse reaction to gadodiamide
    • Thomsen HS (2006) Nephrogenic systemic fibrosis: A serious late adverse reaction to gadodiamide. Eur Radiol 16:2619-2621
    • (2006) Eur Radiol , vol.16 , pp. 2619-2621
    • Thomsen, H.S.1
  • 52
    • 33644849781 scopus 로고    scopus 로고
    • Diameter measurements of the forearm cephalic vein prior to vascular access creation in end-stage renal disease patients: Graduated pressure cuff versus tourniquet vessel dilatation
    • Planken RN, Keuter XH, Hoeks AP, Kooman JP, van der Sande FM, Kessels AG, Leiner T, Tordoir JH (2006) Diameter measurements of the forearm cephalic vein prior to vascular access creation in end-stage renal disease patients: Graduated pressure cuff versus tourniquet vessel dilatation. Nephrol Dial Transplant 21:802-806
    • (2006) Nephrol Dial Transplant , vol.21 , pp. 802-806
    • Planken, R.N.1    Keuter, X.H.2    Hoeks, A.P.3    Kooman, J.P.4    van der Sande, F.M.5    Kessels, A.G.6    Leiner, T.7    Tordoir, J.H.8


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.