메뉴 건너뛰기




Volumn 190, Issue 2, 2008, Pages 294-299

Gas bubble motion artifact in MDCT

Author keywords

Abdominal imaging; Artifact; CT; Gas bubble; Motion

Indexed keywords

ARTICLE; ARTIFACT; COMPUTER SIMULATION; GAS; MOTION; MULTIDETECTOR COMPUTED TOMOGRAPHY; PHANTOM; PRIORITY JOURNAL;

EID: 38849188016     PISSN: 0361803X     EISSN: None     Source Type: Journal    
DOI: 10.2214/AJR.07.2702     Document Type: Article
Times cited : (15)

References (12)
  • 2
    • 32944480555 scopus 로고    scopus 로고
    • Malignant right coronary artery anomaly simulated by motion artifacts on MDCT
    • Katoh M, Wildberger JE, Gunther RW, Buecker A. Malignant right coronary artery anomaly simulated by motion artifacts on MDCT. AJR 2005; 185:1007-1010
    • (2005) AJR , vol.185 , pp. 1007-1010
    • Katoh, M.1    Wildberger, J.E.2    Gunther, R.W.3    Buecker, A.4
  • 3
    • 0023815428 scopus 로고
    • Motion artifacts on CT simulate bronchiectasis
    • Tarver RD, Conces DJ, Godwin JD. Motion artifacts on CT simulate bronchiectasis. AJR 1988; 151:1117-1119
    • (1988) AJR , vol.151 , pp. 1117-1119
    • Tarver, R.D.1    Conces, D.J.2    Godwin, J.D.3
  • 4
    • 0028289096 scopus 로고
    • Predictive respiratory gating: A new method to reduce motion artifacts on CT scans
    • Ritchie CJ, Hsieh J, Gard MF, Godwin JD, Kim Y, Crawford CR. Predictive respiratory gating: a new method to reduce motion artifacts on CT scans. Radiology 1994; 190:847-852
    • (1994) Radiology , vol.190 , pp. 847-852
    • Ritchie, C.J.1    Hsieh, J.2    Gard, M.F.3    Godwin, J.D.4    Kim, Y.5    Crawford, C.R.6
  • 5
    • 0031750641 scopus 로고    scopus 로고
    • Thoracic spiral CT: Influence of subsecond gantry rotation on image quality
    • Rubin GD, Leung AN, Robertson VJ, Stark P. Thoracic spiral CT: influence of subsecond gantry rotation on image quality. Radiology 1998; 208:771-776
    • (1998) Radiology , vol.208 , pp. 771-776
    • Rubin, G.D.1    Leung, A.N.2    Robertson, V.J.3    Stark, P.4
  • 6
    • 0141629561 scopus 로고    scopus 로고
    • Lung at thin-section CT: Influence of multiple-segment reconstruction on image quality
    • Arac M, Oner AY, Celik H, Akpek S, Isik S. Lung at thin-section CT: influence of multiple-segment reconstruction on image quality. Radiology 2003; 229:195-199
    • (2003) Radiology , vol.229 , pp. 195-199
    • Arac, M.1    Oner, A.Y.2    Celik, H.3    Akpek, S.4    Isik, S.5
  • 8
    • 0033668927 scopus 로고    scopus 로고
    • A study on the temperature variation of rise velocity for large clean bubbles
    • Leifer I, Patro RK, Bowyer P. A study on the temperature variation of rise velocity for large clean bubbles. J Atm Ocean Tech 2000; 17:1393-1402
    • (2000) J Atm Ocean Tech , vol.17 , pp. 1393-1402
    • Leifer, I.1    Patro, R.K.2    Bowyer, P.3
  • 9
    • 19744372513 scopus 로고    scopus 로고
    • Influence of surface active substances on bubble motion and collision with various interfaces
    • Malysa K, Krasowska M, Krzan M. Influence of surface active substances on bubble motion and collision with various interfaces. Advan Colloid Interface Sci 2005; 114-115:205-225
    • (2005) Advan Colloid Interface Sci
    • Malysa, K.1    Krasowska, M.2    Krzan, M.3
  • 10
    • 19744369868 scopus 로고    scopus 로고
    • Artifacts in CT: Recognition and avoidance
    • Barrett JF, Keat N. Artifacts in CT: recognition and avoidance. RadioGraphics 2004; 24:1679-1691
    • (2004) RadioGraphics , vol.24 , pp. 1679-1691
    • Barrett, J.F.1    Keat, N.2
  • 11
    • 0034328411 scopus 로고    scopus 로고
    • Motion artifacts in subsecond conventional CT and electron-beam CT: Pictorial visualization of temporal resolution
    • McCollough CH, Bruesewitz MR, Daly TR, Zink FE. Motion artifacts in subsecond conventional CT and electron-beam CT: pictorial visualization of temporal resolution. RadioGraphics 2000; 20:1675-1681
    • (2000) RadioGraphics , vol.20 , pp. 1675-1681
    • McCollough, C.H.1    Bruesewitz, M.R.2    Daly, T.R.3    Zink, F.E.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.