메뉴 건너뛰기




Volumn 229, Issue 1, 2003, Pages 195-199

Lung at thin-section CT: Influence of multiple-segment reconstruction on image quality

Author keywords

Computed tomography (CT), artifact; Computed tomography (CT), image processing; Lung, CT

Indexed keywords

ADULT; AGED; ALGORITHM; ARTICLE; ARTIFACT REDUCTION; BRONCHIECTASIS; CHRONIC OBSTRUCTIVE LUNG DISEASE; CLINICAL ARTICLE; CONTROLLED STUDY; FEMALE; HEART MOVEMENT; HUMAN; IMAGE QUALITY; IMAGE RECONSTRUCTION; INTERSTITIAL LUNG DISEASE; LUNG DISEASE; MALE; PRIORITY JOURNAL; ROTATION; SCORING SYSTEM; SPIRAL COMPUTER ASSISTED TOMOGRAPHY;

EID: 0141629561     PISSN: 00338419     EISSN: None     Source Type: Journal    
DOI: 10.1148/radiol.2291020642     Document Type: Article
Times cited : (6)

References (11)
  • 3
    • 0028072590 scopus 로고
    • CT of the chest and abdomen in patients on mechanical pulmonary ventilators: Quality of images made at 0.6 vs 1.0 sec
    • Posniak HV, Olson MC, Demos TC, Pierce KL, Kalbhen CL. CT of the chest and abdomen in patients on mechanical pulmonary ventilators: quality of images made at 0.6 vs 1.0 sec. AJR Am J Roentgenol 1994; 163:1073-1077.
    • (1994) AJR Am J Roentgenol , vol.163 , pp. 1073-1077
    • Posniak, H.V.1    Olson, M.C.2    Demos, T.C.3    Pierce, K.L.4    Kalbhen, C.L.5
  • 4
    • 0026738437 scopus 로고
    • Minimum scan speeds for suppression of motion artifacts in CT
    • Ritchie CJ, Godwin JD, Crawford CR, et al. Minimum scan speeds for suppression of motion artifacts in CT. Radiology 1992; 185:37-42.
    • (1992) Radiology , vol.185 , pp. 37-42
    • Ritchie, C.J.1    Godwin, J.D.2    Crawford, C.R.3
  • 5
    • 0031750641 scopus 로고    scopus 로고
    • Thoracic spiral CT: Influence of subsecond gantry rotation on image quality
    • Rubin GD, Leung AN, Robertson VJ, Stark P. Thoracic spiral CT: influence of subsecond gantry rotation on image quality. Radiology 1998; 208:771-776.
    • (1998) Radiology , vol.208 , pp. 771-776
    • Rubin, G.D.1    Leung, A.N.2    Robertson, V.J.3    Stark, P.4
  • 6
    • 0034844656 scopus 로고    scopus 로고
    • Thin section CT of the lung: Influence of 0.5-s gantry rotation and ECG triggering on image quality
    • Montaudon M, Berger P, Blachere H, De Boucaud L, Latrabe V, Laurent F. Thin section CT of the lung: influence of 0.5-s gantry rotation and ECG triggering on image quality. Eur Radiol 2001; 9:1681-1687.
    • (2001) Eur Radiol , vol.9 , pp. 1681-1687
    • Montaudon, M.1    Berger, P.2    Blachere, H.3    De Boucaud, L.4    Latrabe, V.5    Laurent, F.6
  • 7
    • 0024582761 scopus 로고
    • Artifacts on lung CT scans: Removal with Fourier filtration
    • Helenon O, Chanin DS, Laval-Jeantet M, Frija J. Artifacts on lung CT scans: removal with Fourier filtration. Radiology 1989; 171:572-574.
    • (1989) Radiology , vol.171 , pp. 572-574
    • Helenon, O.1    Chanin, D.S.2    Laval-Jeantet, M.3    Frija, J.4
  • 9
    • 0021021316 scopus 로고
    • Prospectively gated cardiac computed tomography
    • Moore SC, Judy PF, Garnic J. Prospectively gated cardiac computed tomography. Med Phys 1983; 10:846-855.
    • (1983) Med Phys , vol.10 , pp. 846-855
    • Moore, S.C.1    Judy, P.F.2    Garnic, J.3
  • 10
    • 0033653927 scopus 로고    scopus 로고
    • Thoracic helical CT: Influence of subsecond scan time and thin collimation on evaluation of peripheral pulmonary arteries
    • Remy-Jardin M, Baghaie F, Bonnel F, Masson P, Duhamel A, Remy J. Thoracic helical CT: influence of subsecond scan time and thin collimation on evaluation of peripheral pulmonary arteries. Eur Radiol 2000; 10:1297-1303.
    • (2000) Eur Radiol , vol.10 , pp. 1297-1303
    • Remy-Jardin, M.1    Baghaie, F.2    Bonnel, F.3    Masson, P.4    Duhamel, A.5    Remy, J.6
  • 11
    • 23444451272 scopus 로고
    • Chronic infiltrative lung disease: Comparison of diagnostic accuracies of radiography and low and conventional dose thin section CT
    • Lee KS, Primack SL, Staples CA, et al. Chronic infiltrative lung disease: comparison of diagnostic accuracies of radiography and low and conventional dose thin section CT. Radiology 1994; 191:669-673.
    • (1994) Radiology , vol.191 , pp. 669-673
    • Lee, K.S.1    Primack, S.L.2    Staples, C.A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.