메뉴 건너뛰기




Volumn 3, Issue , 2006, Pages 1832-1836

Experimental measurement of axial and transaxial resolutions of a slit-slat collimator and comparison to theoretical expectations

Author keywords

[No Author keywords available]

Indexed keywords

CAMERAS; COMPUTATIONAL GEOMETRY; COMPUTER SIMULATION; IMAGE RESOLUTION; MONTE CARLO METHODS;

EID: 38649142490     PISSN: 10957863     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/NSSMIC.2006.354250     Document Type: Conference Paper
Times cited : (2)

References (6)
  • 1
    • 34247196834 scopus 로고    scopus 로고
    • On-Axis Sensitivity and Resolution of a Slit-Slat Collimator
    • S.D. Metzler, R. Accorsi, J.R. Novak, A.S. Ayan, R.J. Jaszczak, "On-Axis Sensitivity and Resolution of a Slit-Slat Collimator," J. Nucl. Med., vol. 47, no. 11, pp. 1884-1890, 2006.
    • (2006) J. Nucl. Med , vol.47 , Issue.11 , pp. 1884-1890
    • Metzler, S.D.1    Accorsi, R.2    Novak, J.R.3    Ayan, A.S.4    Jaszczak, R.J.5
  • 2
    • 0000388020 scopus 로고
    • Radioisotope Cameras
    • G.J. Hine, Ed. New York: Academic Press
    • H.O. Anger, "Radioisotope Cameras," in Instrumentation in Nuclear Medicine, vol. 1, G.J. Hine, Ed. New York: Academic Press, 1967, pp. 485-552.
    • (1967) Instrumentation in Nuclear Medicine , vol.1 , pp. 485-552
    • Anger, H.O.1
  • 3
    • 0022525205 scopus 로고
    • Cone beam collimation for single photon emission computed tomography: Analysis, simulation, and image reconstruction using filtered backprojection
    • R.J. Jaszczak, C.E. Floyd, S.H. Manglos, K.X. Greer, and R.E. Coleman, "Cone beam collimation for single photon emission computed tomography: analysis, simulation, and image reconstruction using filtered backprojection," Med. Phys., vol. 13, pp. 484489, 1986.
    • (1986) Med. Phys , vol.13 , pp. 484489
    • Jaszczak, R.J.1    Floyd, C.E.2    Manglos, S.H.3    Greer, K.X.4    Coleman, R.E.5
  • 4
    • 38649135688 scopus 로고    scopus 로고
    • J.H. Hubbell and S.M. Seltzer, Tables of x-ray mass attenuation coefficients and mass energy-absorption coefficients version 1.02, online, National Institute of Standards and Technology, Gaithersburg, MD, 1997. Available:, Accessed September 7, 2006
    • J.H. Hubbell and S.M. Seltzer, "Tables of x-ray mass attenuation coefficients and mass energy-absorption coefficients (version 1.02), [online]," National Institute of Standards and Technology, Gaithersburg, MD, 1997. Available: http://physics.nist.gov/xaamdi. Accessed September 7, 2006.
  • 5
    • 19044382246 scopus 로고    scopus 로고
    • Determination of mechanical and electronic shifts for pinhole SPECT using a single point source
    • S.D. Metzler, K.L. Greer, and R.J. Jaszczak, "Determination of mechanical and electronic shifts for pinhole SPECT using a single point source," IEEE Trans. Med. Img., vol. 24, no. 3, pp. 361-370, 2005.
    • (2005) IEEE Trans. Med. Img , vol.24 , Issue.3 , pp. 361-370
    • Metzler, S.D.1    Greer, K.L.2    Jaszczak, R.J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.