메뉴 건너뛰기




Volumn 47, Issue 11, 2006, Pages 1884-1890

On-axis sensitivity and resolution of a slit-slat collimator

Author keywords

Collimator; Fan beam; Instrumentation; Parallel beam; Pinhole; SPECT

Indexed keywords

ANALYTIC METHOD; ARTICLE; COLLIMATOR; GEOMETRY; MATHEMATICAL COMPUTING; MONTE CARLO METHOD; OPTICAL RESOLUTION; PRIORITY JOURNAL; SENSITIVITY ANALYSIS; ALGORITHM; ANIMAL; AUTOMATION; COMPUTER ASSISTED RADIOTHERAPY; EQUIPMENT DESIGN; HUMAN; IMAGE QUALITY; INSTRUMENTATION; METHODOLOGY; SCINTILLATION CAMERA; SENSITIVITY AND SPECIFICITY; SINGLE PHOTON EMISSION COMPUTER TOMOGRAPHY; THEORETICAL MODEL;

EID: 34247196834     PISSN: 01615505     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (62)

References (7)
  • 1
    • 31844445644 scopus 로고    scopus 로고
    • Evaluation of novel whole-body high-resolution rodent SPECT (Linoview) based on direct acquisition of linogram projections
    • Walrand S, Jamar F, de Jong M, Pauwels S. Evaluation of novel whole-body high-resolution rodent SPECT (Linoview) based on direct acquisition of linogram projections. J Nucl Med. 2005;46:1872-1880.
    • (2005) J Nucl Med , vol.46 , pp. 1872-1880
    • Walrand, S.1    Jamar, F.2    de Jong, M.3    Pauwels, S.4
  • 2
    • 0000388020 scopus 로고
    • Radioisotope cameras
    • Hine GJ, ed, New York, NY: Academic Press;
    • Anger HO. Radioisotope cameras. In: Hine GJ, ed. Instrumentation in Nuclear Medicine. Vol. 1. New York, NY: Academic Press; 1967:485-552.
    • (1967) Instrumentation in Nuclear Medicine , vol.1 , pp. 485-552
    • Anger, H.O.1
  • 3
    • 0022525205 scopus 로고
    • Cone beam collimation for single photon emission computed tomography: Analysis, simulation, and image reconstruction using filtered backprojection
    • Jaszczak RJ, Floyd CE, Manglos SH, Greer KL, Coleman RE. Cone beam collimation for single photon emission computed tomography: analysis, simulation, and image reconstruction using filtered backprojection. Med Phys. 1986;13:484-489.
    • (1986) Med Phys , vol.13 , pp. 484-489
    • Jaszczak, R.J.1    Floyd, C.E.2    Manglos, S.H.3    Greer, K.L.4    Coleman, R.E.5
  • 4
    • 35148813885 scopus 로고    scopus 로고
    • Hubbell JH, Seltzer SM. Tables of x-ray mass attenuation coefficients and mass energy-absorption coefficients version 1.02, National Institute of Standards and Technology Web site. Available at:, Accessed May 8, 2006
    • Hubbell JH, Seltzer SM. Tables of x-ray mass attenuation coefficients and mass energy-absorption coefficients (version 1.02). National Institute of Standards and Technology Web site. Available at: http://physics.nist.gov/xaamdi. Accessed May 8, 2006.
  • 5
    • 19044382246 scopus 로고    scopus 로고
    • Determination of mechanical and electronic shifts for pinhole SPECT using a single point source
    • Metzler SD, Greer KL, Jaszczak RJ. Determination of mechanical and electronic shifts for pinhole SPECT using a single point source. IEEE Trans Med Imaging. 2005;24:361-370.
    • (2005) IEEE Trans Med Imaging , vol.24 , pp. 361-370
    • Metzler, S.D.1    Greer, K.L.2    Jaszczak, R.J.3
  • 7
    • 2942511603 scopus 로고    scopus 로고
    • Analytic determination of the resolution- equivalent effective diameter of a pinhole collimator
    • Accorsi R, Metzler SD. Analytic determination of the resolution- equivalent effective diameter of a pinhole collimator. IEEE Trans Med Imaging. 2004;23:750-763.
    • (2004) IEEE Trans Med Imaging , vol.23 , pp. 750-763
    • Accorsi, R.1    Metzler, S.D.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.