-
1
-
-
48549113488
-
Semiconductor drift chamber - An application of a novel charge transport scheme
-
E. Gatti, P. Rehak, "Semiconductor drift chamber - An application of a novel charge transport scheme", Nucl. Instr. And Meth., A 225, p. 608, 1984.
-
(1984)
Nucl. Instr. And Meth., A
, vol.225
, pp. 608
-
-
Gatti, E.1
Rehak, P.2
-
2
-
-
0030214002
-
Silicon drift detectors for high resolution room temperature X-ray spectroscopy
-
P. Lechner, S. Eckbauer, R. Hartmann, S. Krisch, D. Hauff, R. Richter, H. Soltau, L. Struder, C. Fiorini, E. Gatti, A. Longoni, M. Sampietro, "Silicon drift detectors for high resolution room temperature X-ray spectroscopy", Nucl. Instr. and Meth., A 377, pp. 346-351, 1996.
-
(1996)
Nucl. Instr. and Meth., A
, vol.377
, pp. 346-351
-
-
Lechner, P.1
Eckbauer, S.2
Hartmann, R.3
Krisch, S.4
Hauff, D.5
Richter, R.6
Soltau, H.7
Struder, L.8
Fiorini, C.9
Gatti, E.10
Longoni, A.11
Sampietro, M.12
-
3
-
-
33745894652
-
-
C. de Haen, P.L. Anelli PL, V. Lorusso, A. Morsetti, K. Maggiotii, J. Zheng, K. Uggeri, F.M. Lavagna, Gadocoletic acid trisodium salt (B22956/1): a new blood pool magnetic resonance contrast agent with application in coronary angiography. Invest Radiol., 41, pp. 279-91, 2006.
-
C. de Haen, P.L. Anelli PL, V. Lorusso, A. Morsetti, K. Maggiotii, J. Zheng, K. Uggeri, F.M. Lavagna, "Gadocoletic acid trisodium salt (B22956/1): a new blood pool magnetic resonance contrast agent with application in coronary angiography." Invest Radiol., 41, pp. 279-91, 2006.
-
-
-
-
4
-
-
27944444026
-
CMagnetic Resonance Contrast Agents: From the Bench to the Patient
-
V. Lorusso, L. Pascolo, C. Fernetti, P. L.Anelli, K. Uggeri, C. Tiribelli, "CMagnetic Resonance Contrast Agents: From the Bench to the Patient". Curr. Pharm. Des., 1, pp. 4079-4098, 2005
-
(2005)
Curr. Pharm. Des
, vol.1
, pp. 4079-4098
-
-
Lorusso, V.1
Pascolo, L.2
Fernetti, C.3
Anelli, P.L.4
Uggeri, K.5
Tiribelli, C.6
-
5
-
-
3242882397
-
Novel high-resolution silicon drift detectors
-
July/August
-
P. Lechner, A. Pahlke, H. Soltau, "Novel high-resolution silicon drift detectors", X-ray Spectrometry, Vol. 33, pp. 256-261, July/August 2004.
-
(2004)
X-ray Spectrometry
, vol.33
, pp. 256-261
-
-
Lechner, P.1
Pahlke, A.2
Soltau, H.3
-
6
-
-
33750307586
-
High-rate X-ray spectroscopy using a Silicon Drift Detector and a charge preamplifier
-
R. Alberti, C. Fiorini, A. Longoni, H. Soltau "High-rate X-ray spectroscopy using a Silicon Drift Detector and a charge preamplifier" Nucl. Instr: and Meth,. A 568, 106-111, 2006
-
(2006)
Nucl. Instr: And Meth,. A
, vol.568
, pp. 106-111
-
-
Alberti, R.1
Fiorini, C.2
Longoni, A.3
Soltau, H.4
-
7
-
-
27644597232
-
High-speed KPGA-based pulse-hight analyzer for high resolution X-ray spectroscopy
-
August
-
S. Buzzetti, M. Capou, C. Guazzoni, A. Longoni, R. Mariani, S. Moser, "High-speed KPGA-based pulse-hight analyzer for high resolution X-ray spectroscopy", IEEE Trans. Nucl. Sci., Vol. 52, no.4, pp. 854-860, August 2005.
-
(2005)
IEEE Trans. Nucl. Sci
, vol.52
, Issue.4
, pp. 854-860
-
-
Buzzetti, S.1
Capou, M.2
Guazzoni, C.3
Longoni, A.4
Mariani, R.5
Moser, S.6
-
8
-
-
0000870544
-
Die Kinetik der Invertihwirkung
-
Leonor Michaelis, Maud Menten. "Die Kinetik der Invertihwirkung", Biohem. Z. 49:333-369, 1913.
-
(1913)
Biohem. Z
, vol.49
, pp. 333-369
-
-
Michaelis, L.1
Menten, M.2
|