메뉴 건너뛰기




Volumn 5, Issue 4, 2007, Pages 298-301

Floating-reference method of noninvasive blood glucose concentration measurement

Author keywords

Blood glucose concentration; Floating reference method; Radial reference location

Indexed keywords

BLOOD GLUCOSE CONCENTRATION; FLOATING REFERENCE METHOD; MONTE CARLO SIMULATION; RADIAL REFERENCE LOCATION;

EID: 38649109164     PISSN: 16726030     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (8)

References (10)
  • 1
    • 79951989379 scopus 로고    scopus 로고
    • Method for predicting the blood glucose level of a pereon: USA, 20060253008
    • Chung J, Fan K, Wong T, et al. Method for predicting the blood glucose level of a pereon: USA, 20060253008[P]. 2006-09-11.
    • (2006)
    • Chung, J.1    Fan, K.2    Wong, T.3
  • 2
    • 6044275963 scopus 로고    scopus 로고
    • Non-invasive glucose measurement technologies: An update from 1999 to the dawn of the new millennium
    • Khalil O S. Non-invasive glucose measurement technologies: An update from 1999 to the dawn of the new millennium[J]. Diabetes Technol Ther, 2004, 6(6): 660-697.
    • (2004) Diabetes Technol Ther , vol.6 , Issue.6 , pp. 660-697
    • Khalil, O.S.1
  • 3
    • 21744447919 scopus 로고    scopus 로고
    • Non-invasive glucose sensing with near-infrared spectroscopy enhanced by optical measurement conditions reproduction technique
    • Xu Kexin, Qiu Qinjun, Jiang Jingying, et al. Non-invasive glucose sensing with near-infrared spectroscopy enhanced by optical measurement conditions reproduction technique[J]. Optics and Lasers in Engineering, 2005, 13(10): 1096-1106.
    • (2005) Optics and Lasers in Engineering , vol.13 , Issue.10 , pp. 1096-1106
    • Xu, K.1    Qiu, Q.2    Jiang, J.3
  • 4
    • 0242269450 scopus 로고    scopus 로고
    • In vivo noninvasive measurement of blood glucose by near-infrared diffuse-reflectance spectroscopy
    • Maruo K, Tsurugi M, Tamura M, et al. In vivo noninvasive measurement of blood glucose by near-infrared diffuse-reflectance spectroscopy[J]. Appl Spectrosc, 2003, 57(10): 1236-1244.
    • (2003) Appl Spectrosc , vol.57 , Issue.10 , pp. 1236-1244
    • Maruo, K.1    Tsurugi, M.2    Tamura, M.3
  • 5
    • 0034064170 scopus 로고    scopus 로고
    • Noninvasive blood glucose measurements by near-infrared transmission spectroscopy across human tongues
    • Burmeister J J, Arnold M A, Small G W. Noninvasive blood glucose measurements by near-infrared transmission spectroscopy across human tongues[J]. Diabetes Technol Ther, 2000, 2(1): 5-16.
    • (2000) Diabetes Technol Ther , vol.2 , Issue.1 , pp. 5-16
    • Burmeister, J.J.1    Arnold, M.A.2    Small, G.W.3
  • 6
    • 38649116214 scopus 로고    scopus 로고
    • in Chinese
  • 7
    • 33745323103 scopus 로고    scopus 로고
    • Discussion on floating-reference method for noninvasive measurement of blood glucose with near-infrared spectroscopy
    • California USA
    • Luo Yunhan, An Lin, Ma Zhen, et al. Discussion on floating-reference method for noninvasive measurement of blood glucose with near-infrared spectroscopy[C]//Progress in Biomedical Optics and Imaging (Proceedings of SPIE). California USA, 2006: 60940K.
    • (2006) Progress in Biomedical Optics and Imaging (Proceedings of SPIE)
    • Luo, Y.1    An, L.2    Ma, Z.3
  • 8
    • 34247365019 scopus 로고    scopus 로고
    • Applying the floating-reference method to improve the precision of noninvasive blood glucose measurement
    • California, USA
    • Chen Wenliang, Ma Zhen, An Lin, et al. Applying the floating-reference method to improve the precision of noninvasive blood glucose measurement[C]//Progress in Biomedical Optics and Imaging (Proceedings of SPIE). California, USA, 2007: 64450M.
    • (2007) Progress in Biomedical Optics and Imaging (Proceedings of SPIE)
    • Chen, W.1    Ma, Z.2    An, L.3
  • 10
    • 0242493198 scopus 로고    scopus 로고
    • Noninvasive blood glucose assay using a newly developed near-infrared system
    • Maruo K, Tsurugi M, Chin J, et al. Noninvasive blood glucose assay using a newly developed near-infrared system[J]. IEEE J Sel Topics in Quan Electronics, 2003, 9(2): 322-330.
    • (2003) IEEE J Sel Topics in Quan Electronics , vol.9 , Issue.2 , pp. 322-330
    • Maruo, K.1    Tsurugi, M.2    Chin, J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.