1
-
-
6044275963
-
Non-invasive glucose measurement technologies: An update from 1999 to the dawn of the new millennium
-
Omar S. Khalil, "Non-invasive glucose measurement technologies: an update from 1999 to the dawn of the new millennium," Diabetes Technol. Ther., 6:660-97, 2004.
-
(2004)
Diabetes Technol. Ther
, vol.6
, pp. 660-697
-
-
Khalil, O.S.1
-
2
-
-
26444554176
-
Scattering and absorption effects in the determination of glucose in whole blood by near-infrared spectroscopy
-
A. K. Amerov, J. Chen, G. W. Small, et al., "Scattering and absorption effects in the determination of glucose in whole blood by near-infrared spectroscopy," Anal Chem., 77:4587-4594, 2005.
-
(2005)
Anal Chem
, vol.77
, pp. 4587-4594
-
-
Amerov, A.K.1
Chen, J.2
Small, G.W.3
-
3
-
-
33744771301
-
New Methodology to Obtain a Calibration Model for Noninvasive Near-Infrared Blood Glucose Monitoring
-
K. Maruo, T. Oota, Y. Yamada, et al., "New Methodology to Obtain a Calibration Model for Noninvasive Near-Infrared Blood Glucose Monitoring," Appl. Spec., 60: 441-449, 2006.
-
(2006)
Appl. Spec
, vol.60
, pp. 441-449
-
-
Maruo, K.1
Oota, T.2
Yamada, Y.3
-
4
-
-
34247353005
-
-
Ph.D. dissertation, Tianjin University, Tianjin, China, in Chinese
-
W. Chen, Study on Theories and Experiments of Signal Acquisition for Non-Invasive Blood Glucose Sensing with Near-Infrared Spectroscopy, Ph.D. dissertation, Tianjin University, Tianjin, China, 2005. (in Chinese)
-
(2005)
Study on Theories and Experiments of Signal Acquisition for Non-Invasive Blood Glucose Sensing with Near-Infrared Spectroscopy
-
-
Chen, W.1
-
5
-
-
23244467730
-
Analysis of sensitivity and optical path-length in non-invasive measurement of glucose with near infrared spectroscopy
-
Y. Luo, R. Liu, W. Chen, et al., "Analysis of sensitivity and optical path-length in non-invasive measurement of glucose with near infrared spectroscopy," Proc.SPIE, 5696:205-214, 2005.
-
(2005)
Proc.SPIE
, vol.5696
, pp. 205-214
-
-
Luo, Y.1
Liu, R.2
Chen, W.3
-
6
-
-
84975647283
-
Time resolved reflectance and transmittance for the noninvasive measurement of tissue optical properties
-
M. S. Patterson, B. Chance, and B. C. Wilson, "Time resolved reflectance and transmittance for the noninvasive measurement of tissue optical properties," Appl. Opt., 28: 2331-2342, 1989.
-
(1989)
Appl. Opt
, vol.28
, pp. 2331-2342
-
-
Patterson, M.S.1
Chance, B.2
Wilson, B.C.3
-
7
-
-
0029077394
-
The influence of glucose concentration upon the transport of light in tissue-simulating phantoms
-
M. Kohlt, M. Essenpreist and M. Copet, "The influence of glucose concentration upon the transport of light in tissue-simulating phantoms," Phys. Med. Biol., 40:1267-1287, 1995.
-
(1995)
Phys. Med. Biol
, vol.40
, pp. 1267-1287
-
-
Kohlt, M.1
Essenpreist, M.2
Copet, M.3
-
8
-
-
0021080356
-
A Monte Carlo model for the absorption and flux distributions of light in tissue
-
B. C. Wilson and G. Adams, "A Monte Carlo model for the absorption and flux distributions of light in tissue," Med. Phys., 10:824-830, 1983.
-
(1983)
Med. Phys
, vol.10
, pp. 824-830
-
-
Wilson, B.C.1
Adams, G.2
-
9
-
-
0029045693
-
MCML-Monte carlo modeling of light transport in multi-layered tissue
-
L. Wang, S.L. Jacques, and L. Zheng, "MCML-Monte carlo modeling of light transport in multi-layered tissue," Computer Methods and Programs in Biomedicine, 47:131-146, 1995.
-
(1995)
Computer Methods and Programs in Biomedicine
, vol.47
, pp. 131-146
-
-
Wang, L.1
Jacques, S.L.2
Zheng, L.3
-
10
-
-
0242493198
-
Noninvasive blood glucose assay using a newly developed near-infrared system
-
K. Maruo, M. Tsurugi, J. Chin, et al., "Noninvasive blood glucose assay using a newly developed near-infrared system," IEEE J. sel. topics in quan. Electronics, 9:322-330, 2003.
-
(2003)
IEEE J. sel. topics in quan. Electronics
, vol.9
, pp. 322-330
-
-
Maruo, K.1
Tsurugi, M.2
Chin, J.3
-
11
-
-
33744955028
-
A Study of Blood Glucose Concentration Measurement by Scattering Coefficient
-
Z. He, Y. Luo, K. Xu, et al., "A Study of Blood Glucose Concentration Measurement by Scattering Coefficient," Acta Optica Sinica, 26: 591-594, 2006.
-
(2006)
Acta Optica Sinica
, vol.26
, pp. 591-594
-
-
He, Z.1
Luo, Y.2
Xu, K.3
|