메뉴 건너뛰기




Volumn 221, Issue 8, 2007, Pages 929-942

Can cobalt levels estimate in-vivo wear of metal-on-metal bearings used in hip arthroplasty?

Author keywords

Hip arthroplasty; Metal on metal; Wear

Indexed keywords

COBALT; LUBRICATION; METAL IONS; WEAR OF MATERIALS; ARTHROPLASTY; DEBRIS; HIP PROSTHESES; LOADING; ORTHOPEDICS;

EID: 38449101509     PISSN: 09544119     EISSN: None     Source Type: Journal    
DOI: 10.1243/09544119JEIM270     Document Type: Review
Times cited : (13)

References (82)
  • 1
    • 0031837235 scopus 로고    scopus 로고
    • Charnley total hip arthroplasty in patients less than fifty years old. A twenty to twenty-five-year follow-up note
    • Callaghan, J. J., Forest, E. E., Olejniczak, J. P., Goetz, D. D., and Johnston, R. C. Charnley total hip arthroplasty in patients less than fifty years old. A twenty to twenty-five-year follow-up note. J. Bone Jt Surg. Am., 1998, 80(5), 704-714.
    • (1998) J. Bone Jt Surg. Am , vol.80 , Issue.5 , pp. 704-714
    • Callaghan, J.J.1    Forest, E.E.2    Olejniczak, J.P.3    Goetz, D.D.4    Johnston, R.C.5
  • 2
    • 0020541681 scopus 로고
    • Total hip arthroplasties in patients less than forty-five years old
    • Dorr, L. D., Takei, G. K., and Conaty, J. P. Total hip arthroplasties in patients less than forty-five years old. J. Bone Jt Surg. Am., 1983, 65(4), 474-479.
    • (1983) J. Bone Jt Surg. Am , vol.65 , Issue.4 , pp. 474-479
    • Dorr, L.D.1    Takei, G.K.2    Conaty, J.P.3
  • 3
    • 0025165926 scopus 로고
    • Total hip arthroplasties in patients younger than 45 years. A nine- to ten-year follow-up study
    • Dorr, L. D., Luckett, M., and Conaty, J. P. Total hip arthroplasties in patients younger than 45 years. A nine- to ten-year follow-up study. Clin. Orthop. Relat. Res., 1990, 260, 215-219.
    • (1990) Clin. Orthop. Relat. Res , vol.260 , pp. 215-219
    • Dorr, L.D.1    Luckett, M.2    Conaty, J.P.3
  • 4
    • 0028139402 scopus 로고
    • Long-term results of cemented total hip arthroplasty in patients 45 years old or younger. A 16-year follow-up study
    • Dorr, L. D., Kane, T. J. III, and Conaty, J. P. Long-term results of cemented total hip arthroplasty in patients 45 years old or younger. A 16-year follow-up study. J. Arthroplasty, 1994, 9(5), 453-456.
    • (1994) J. Arthroplasty , vol.9 , Issue.5 , pp. 453-456
    • Dorr, L.D.1    Kane III, T.J.2    Conaty, J.P.3
  • 7
    • 0942298191 scopus 로고    scopus 로고
    • Biologic and tribologic considerations of alternative bearing surfaces
    • Campbell, P. S., Shen, F. W., and McKellop, H. Biologic and tribologic considerations of alternative bearing surfaces. Clin. Orthop. Relat. Res., 2004, 418, 98-111.
    • (2004) Clin. Orthop. Relat. Res , vol.418 , pp. 98-111
    • Campbell, P.S.1    Shen, F.W.2    McKellop, H.3
  • 8
    • 0000325373 scopus 로고    scopus 로고
    • Size and shape of metal particles from metal on metal total hip replacements
    • Soh, F. B., Blunn, G. W., Wait, M. E., and Walker, P. S. Size and shape of metal particles from metal on metal total hip replacements. Trans. Orthop. Res. Soc., 1996, 21, 462-471.
    • (1996) Trans. Orthop. Res. Soc , vol.21 , pp. 462-471
    • Soh, F.B.1    Blunn, G.W.2    Wait, M.E.3    Walker, P.S.4
  • 9
    • 0032190304 scopus 로고    scopus 로고
    • Metal wear particle characterization from metal on metal total hip replacements: Transmission electron microscopy study of periprosthetic tissues and isolated particles
    • Doorn, P. F., Campbell, P. A., Worrall, J., Benya, P. D., McKellop, H. A., and Amstutz, H. C. Metal wear particle characterization from metal on metal total hip replacements: transmission electron microscopy study of periprosthetic tissues and isolated particles. J. Biomed. Mater Res., 1998, 42(1), 103-111.
    • (1998) J. Biomed. Mater Res , vol.42 , Issue.1 , pp. 103-111
    • Doorn, P.F.1    Campbell, P.A.2    Worrall, J.3    Benya, P.D.4    McKellop, H.A.5    Amstutz, H.C.6
  • 10
    • 0017462028 scopus 로고
    • Reaction of the articular capsule to wear products of artificial joint prostheses
    • Willert, H. G. Reaction of the articular capsule to wear products of artificial joint prostheses. J. Biomed. Mater Res., 1977, 11(2), 157-164.
    • (1977) J. Biomed. Mater Res , vol.11 , Issue.2 , pp. 157-164
    • Willert, H.G.1
  • 12
    • 0031938258 scopus 로고    scopus 로고
    • Wear and osteolysis in total joint replacements
    • Kadoya, Y., Kobayashi, A., and Ohashi, H. Wear and osteolysis in total joint replacements. Acta Orthop. Scand., 1998, 69(Suppl. 278), 1-16.
    • (1998) Acta Orthop. Scand , vol.69 , Issue.SUPPL. 278 , pp. 1-16
    • Kadoya, Y.1    Kobayashi, A.2    Ohashi, H.3
  • 13
    • 0026662669 scopus 로고
    • Periprosthetic bone loss in total hip arthroplasty. Polyethylene wear debris and the concept of the effective joint space
    • Schmalzried, T. P., Jasty, M., and Harris, W. H. Periprosthetic bone loss in total hip arthroplasty. Polyethylene wear debris and the concept of the effective joint space. J. Bone Jt Surg. Am., 1992, 74(6), 849-863.
    • (1992) J. Bone Jt Surg. Am , vol.74 , Issue.6 , pp. 849-863
    • Schmalzried, T.P.1    Jasty, M.2    Harris, W.H.3
  • 16
    • 0029813581 scopus 로고    scopus 로고
    • Preliminary observations on possible premalignant changes in bone marrow adjacent to worn total hip arthroplasty implants
    • Case, C. P., Langkamer, V. G., Howell, R. T., Webb, J., Standen, G., Palmer, M., Kemp, A., and Learmonth, I. D. Preliminary observations on possible premalignant changes in bone marrow adjacent to worn total hip arthroplasty implants. Clin. Orthop. Relat. Res., 1996, 329(Suppl.), S269-S279.
    • (1996) Clin. Orthop. Relat. Res , vol.329 , Issue.SUPPL.
    • Case, C.P.1    Langkamer, V.G.2    Howell, R.T.3    Webb, J.4    Standen, G.5    Palmer, M.6    Kemp, A.7    Learmonth, I.D.8
  • 18
    • 0022400969 scopus 로고    scopus 로고
    • Waterman, A. H. and Schrik, J. J. Allergy in hip arthroplasty. Contact Dermatitis, 1985, 13(5), 294-301.
    • Waterman, A. H. and Schrik, J. J. Allergy in hip arthroplasty. Contact Dermatitis, 1985, 13(5), 294-301.
  • 19
    • 11844293972 scopus 로고    scopus 로고
    • Metal-on-metal bearings and hypersensitivity in patients with artificial hip joints. A clinical and histomorphological study
    • Willert, H. G., Buchhorn, G. H., Fayyazi, A., Flury, R., Windler, M., Koster, G., and Lohmann, C. H. Metal-on-metal bearings and hypersensitivity in patients with artificial hip joints. A clinical and histomorphological study. J. Bone Jt Surg. Am., 2005, 87(1), 28-36.
    • (2005) J. Bone Jt Surg. Am , vol.87 , Issue.1 , pp. 28-36
    • Willert, H.G.1    Buchhorn, G.H.2    Fayyazi, A.3    Flury, R.4    Windler, M.5    Koster, G.6    Lohmann, C.H.7
  • 20
    • 21444450339 scopus 로고    scopus 로고
    • Early osteolysis following second-generation metal-on-metal hip replacement
    • Park, Y. S., Moon, Y. W., Lim, S. J., Yang, J. M., Ahn, G., and Choi, Y. L. Early osteolysis following second-generation metal-on-metal hip replacement. J. Bone Jt Surg. Am., 2005, 87(7), 1515-1521.
    • (2005) J. Bone Jt Surg. Am , vol.87 , Issue.7 , pp. 1515-1521
    • Park, Y.S.1    Moon, Y.W.2    Lim, S.J.3    Yang, J.M.4    Ahn, G.5    Choi, Y.L.6
  • 21
    • 0036774766 scopus 로고    scopus 로고
    • Positive cytokine production in failed metal-on-metal total hip replacements
    • Campbell, P. A., Wang, M., Amstutz, H. C., and Goodman, S. B. Positive cytokine production in failed metal-on-metal total hip replacements. Acta Orthop. Scand., 2002, 73(5), 506-512.
    • (2002) Acta Orthop. Scand , vol.73 , Issue.5 , pp. 506-512
    • Campbell, P.A.1    Wang, M.2    Amstutz, H.C.3    Goodman, S.B.4
  • 22
    • 0028073911 scopus 로고
    • Migration of corrosion products from modular hip prostheses. Particle microanalysis and histopathological findings
    • Urban, R. M., Jacobs, J. J., Gilbert, J. L., and Galante, J. O. Migration of corrosion products from modular hip prostheses. Particle microanalysis and histopathological findings. J. Bone Jt Surg. Am., 1994, 76(9), 1345-1359.
    • (1994) J. Bone Jt Surg. Am , vol.76 , Issue.9 , pp. 1345-1359
    • Urban, R.M.1    Jacobs, J.J.2    Gilbert, J.L.3    Galante, J.O.4
  • 24
    • 0024059621 scopus 로고
    • Does corrosion matter?
    • Black, J. Does corrosion matter? J. Bone Jt Surg. Br., 1988, 70(4), 517-520.
    • (1988) J. Bone Jt Surg. Br , vol.70 , Issue.4 , pp. 517-520
    • Black, J.1
  • 26
    • 0027897650 scopus 로고
    • In vivo corrosion of modular hip prosthesis components in mixed and similar metal combinations. The effect of crevice, stress, motion, and alloy coupling
    • Gilbert, J. L., Buckley, C. A., and Jacobs, J. J. In vivo corrosion of modular hip prosthesis components in mixed and similar metal combinations. The effect of crevice, stress, motion, and alloy coupling. J. Biomed. Mater Res., 1993, 27(12), 1533-1544.
    • (1993) J. Biomed. Mater Res , vol.27 , Issue.12 , pp. 1533-1544
    • Gilbert, J.L.1    Buckley, C.A.2    Jacobs, J.J.3
  • 27
    • 0032997938 scopus 로고    scopus 로고
    • Metallosis due to impingement between the socket and the femoral neck in a metal-on-metal bearing total hip prosthesis. A case report
    • Iida, H., Kaneda, E., Takada, H., Uchida, K., Kawanabe, K., and Nakamura, T. Metallosis due to impingement between the socket and the femoral neck in a metal-on-metal bearing total hip prosthesis. A case report. J. Bone Jt Surg. Am., 1999, 81(3), 400-403.
    • (1999) J. Bone Jt Surg. Am , vol.81 , Issue.3 , pp. 400-403
    • Iida, H.1    Kaneda, E.2    Takada, H.3    Uchida, K.4    Kawanabe, K.5    Nakamura, T.6
  • 30
    • 0025689518 scopus 로고
    • Tissue response in relation to type of wear particles around failed hip arthroplasties
    • Howie, D. W. Tissue response in relation to type of wear particles around failed hip arthroplasties. J. Arthroplasty, 1990, 5(4), 337-348.
    • (1990) J. Arthroplasty , vol.5 , Issue.4 , pp. 337-348
    • Howie, D.W.1
  • 31
    • 0036943695 scopus 로고    scopus 로고
    • Cobalt and chromium concentrations in patients with metal-on-metal and other cementless total hip arthroplasty
    • Maezawa, K., Nozawa, M., Hirose, T., Matsuda, K., Yasuma, M., Shitoto, K., and Kurosawa, H. Cobalt and chromium concentrations in patients with metal-on-metal and other cementless total hip arthroplasty. Arch. Orthop. Trauma Surg., 2002, 122(5), 283-287.
    • (2002) Arch. Orthop. Trauma Surg , vol.122 , Issue.5 , pp. 283-287
    • Maezawa, K.1    Nozawa, M.2    Hirose, T.3    Matsuda, K.4    Yasuma, M.5    Shitoto, K.6    Kurosawa, H.7
  • 32
    • 0036030847 scopus 로고    scopus 로고
    • Effects of marathon running on the trace minerals chromium, cobalt, nickel, and molybdenum
    • Berger, C. E. K., Kluger, A., Baron, R., Steffan, I., and Engel, A. Effects of marathon running on the trace minerals chromium, cobalt, nickel, and molybdenum. J. Race Elements Expl Medicine, 2002, 15(4), 201-209.
    • (2002) J. Race Elements Expl Medicine , vol.15 , Issue.4 , pp. 201-209
    • Berger, C.E.K.1    Kluger, A.2    Baron, R.3    Steffan, I.4    Engel, A.5
  • 33
    • 0038051813 scopus 로고    scopus 로고
    • Cobalt blood levels after total hip replacement (THR): A new follow-up study in Trieste (Italy)
    • Adami, G., Smarrelli, D., Martinelli, B., Acquavita, A., and Reisenhofer, E. Cobalt blood levels after total hip replacement (THR): a new follow-up study in Trieste (Italy). Ann. Chim., 2003, 93(1-2), 1-10.
    • (2003) Ann. Chim , vol.93 , Issue.1-2 , pp. 1-10
    • Adami, G.1    Smarrelli, D.2    Martinelli, B.3    Acquavita, A.4    Reisenhofer, E.5
  • 35
    • 0037224605 scopus 로고    scopus 로고
    • Four-year study of cobalt and chromium blood levels in patients managed with two different metal-on-metal total hip replacements
    • Lhotka, C., Szekeres, T., Steffan, I., Zhuber, K., and Zweymuller, K. Four-year study of cobalt and chromium blood levels in patients managed with two different metal-on-metal total hip replacements. J. Orthop. Res., 2003, 21(2), 189-195.
    • (2003) J. Orthop. Res , vol.21 , Issue.2 , pp. 189-195
    • Lhotka, C.1    Szekeres, T.2    Steffan, I.3    Zhuber, K.4    Zweymuller, K.5
  • 39
  • 41
    • 0035045395 scopus 로고    scopus 로고
    • Quantitative analysis of wear and wear debris from metal-on-metal hip prostheses tested in a physiological hip joint simulator
    • Firkins, P. J., Tipper, I. L, Saadatzadeh, M. R., Ingham, E., Stone, M. H., Farrar, R., and Fisher, J. Quantitative analysis of wear and wear debris from metal-on-metal hip prostheses tested in a physiological hip joint simulator. Biomed. Mater. Engng, 2001, 11(2), 143-157.
    • (2001) Biomed. Mater. Engng , vol.11 , Issue.2 , pp. 143-157
    • Firkins, P.J.1    Tipper, I.L.2    Saadatzadeh, M.R.3    Ingham, E.4    Stone, M.H.5    Farrar, R.6    Fisher, J.7
  • 42
    • 0035736451 scopus 로고    scopus 로고
    • Scholes, S. C., Green, S. M., and Unsworth, A. The wear of metal-on-metal total hip prostheses measured in a hip simulator. Proc. Instn Mech. Engrs, Part D: J. Engineering in Medicine, 2001, 215(6), 523-530.
    • Scholes, S. C., Green, S. M., and Unsworth, A. The wear of metal-on-metal total hip prostheses measured in a hip simulator. Proc. Instn Mech. Engrs, Part D: J. Engineering in Medicine, 2001, 215(6), 523-530.
  • 43
    • 0032949430 scopus 로고    scopus 로고
    • Analysis of 118 second-generation metal-on-metal retrieved hip implants
    • Sieber, H. P., Rieker, C. B., and, Kottig, P. Analysis of 118 second-generation metal-on-metal retrieved hip implants. J. Bone Jt Surg. Br., 1999, 81(1), 46-50.
    • (1999) J. Bone Jt Surg. Br , vol.81 , Issue.1 , pp. 46-50
    • Sieber, H.P.1    Rieker, C.B.2    Kottig, P.3
  • 44
    • 0036909674 scopus 로고    scopus 로고
    • Roter, G. E., Medley, J. B., Bobyn, I. D., Krygier, J. J., and Chan, F. W. Intermittent motion: a novel simulator protocol for ttie wear of metal-metel hip implants. In Boundary and mixed lubrication: science and application, Proceedings of the 28th Leeds - Lyon Symposium on Tribology, Elsevier Tribology Series, 40, Vienna, Austria, 4-7 September 2001, 2002, pp. 367-376 (Elsevier, Amsterdam).
    • Roter, G. E., Medley, J. B., Bobyn, I. D., Krygier, J. J., and Chan, F. W. Intermittent motion: a novel simulator protocol for ttie wear of metal-metel hip implants. In Boundary and mixed lubrication: science and application, Proceedings of the 28th Leeds - Lyon Symposium on Tribology, Elsevier Tribology Series, Vol. 40, Vienna, Austria, 4-7 September 2001, 2002, pp. 367-376 (Elsevier, Amsterdam).
  • 45
    • 33645217648 scopus 로고    scopus 로고
    • Bowsher, J. G., Hussain, A., Williams, P A., and Shelton, J. C. Metal-on-metal hip simulator study of increased wear particle surface area due to 'severe' patient activity. Proc. IMechE, Part D: J. Engineering in Medicine, 2006, 220(2), 279-287.
    • Bowsher, J. G., Hussain, A., Williams, P A., and Shelton, J. C. Metal-on-metal hip simulator study of increased wear particle surface area due to 'severe' patient activity. Proc. IMechE, Part D: J. Engineering in Medicine, 2006, 220(2), 279-287.
  • 46
    • 0032837830 scopus 로고    scopus 로고
    • Quantitative analysis of the wear and wear debris from low and high carbon content cobalt chrome alloyq used in metal on metal total hip replacements
    • Tipper, J. L., Firkins, P. J., Ingham, E., Fisher, J., Stone, M. H., and Farrar, R. Quantitative analysis of the wear and wear debris from low and high carbon content cobalt chrome alloyq used in metal on metal total hip replacements. J. Mater Sci.: Mater Medicine, 1999, 10(6), 353-362.
    • (1999) J. Mater Sci.: Mater Medicine , vol.10 , Issue.6 , pp. 353-362
    • Tipper, J.L.1    Firkins, P.J.2    Ingham, E.3    Fisher, J.4    Stone, M.H.5    Farrar, R.6
  • 47
    • 0035065646 scopus 로고    scopus 로고
    • Firkins, P. J., Tipper, J. L., Ingham, E., Stone, M. H., Farrar, R., and Fisher, J. Influence of simulator kinematics on the wear of metal-on-metal hip prostheses. Proc. Instn Mech. Engrs, Part D: J. Engineering in Medicine, 2001, 215(1), 119-121.
    • Firkins, P. J., Tipper, J. L., Ingham, E., Stone, M. H., Farrar, R., and Fisher, J. Influence of simulator kinematics on the wear of metal-on-metal hip prostheses. Proc. Instn Mech. Engrs, Part D: J. Engineering in Medicine, 2001, 215(1), 119-121.
  • 48
    • 0016942059 scopus 로고
    • The wear of plastic materials in the hip-joint
    • Charnley, J. The wear of plastic materials in the hip-joint. Plastics Rubber, 1976, 1, 59-63.
    • (1976) Plastics Rubber , vol.1 , pp. 59-63
    • Charnley, J.1
  • 49
    • 0034233164 scopus 로고    scopus 로고
    • The effects of material combination and lubricant on the friction of total hip prostheses
    • Scholes, S. C., Unsworth, A., Hall, R. M., and Scott, R. The effects of material combination and lubricant on the friction of total hip prostheses. Wear, 2002, 241, 209-213.
    • (2002) Wear , vol.241 , pp. 209-213
    • Scholes, S.C.1    Unsworth, A.2    Hall, R.M.3    Scott, R.4
  • 51
    • 17044413641 scopus 로고    scopus 로고
    • Influenqe of the clearance on in-vitro tribology of large diameter metal-on-metal articulations pertaining to resurfacing hip implants
    • vii
    • Rieker, C. B., Schon, R., Konrad, R., Liebentritt, G., Gnepf, P., Shen, M., Roberts, P., and Grigoris, P. Influenqe of the clearance on in-vitro tribology of large diameter metal-on-metal articulations pertaining to resurfacing hip implants. Orthop. Clin. North. Am., 2005, 36(2), 135-142, vii.
    • (2005) Orthop. Clin. North. Am , vol.36 , Issue.2 , pp. 135-142
    • Rieker, C.B.1    Schon, R.2    Konrad, R.3    Liebentritt, G.4    Gnepf, P.5    Shen, M.6    Roberts, P.7    Grigoris, P.8
  • 52
    • 17544388139 scopus 로고    scopus 로고
    • Wang, A., Yue, S., Bobyn, Chin, F. W., and Medley, J. B. Surface characterization of metal-on-metal implants tested in, a hip simulator. Wear, 1999, 225, 708-715.
    • Wang, A., Yue, S., Bobyn, Chin, F. W., and Medley, J. B. Surface characterization of metal-on-metal implants tested in, a hip simulator. Wear, 1999, 225, 708-715.
  • 54
    • 0037399485 scopus 로고    scopus 로고
    • Elastohydrodynamic lubrication analysis of metal-on-metal hip-resurfacing prostheses
    • Udofia, I. J. and Jin, Z. M. Elastohydrodynamic lubrication analysis of metal-on-metal hip-resurfacing prostheses. J. Biomechanics, 2003, 36(4), 537-544.
    • (2003) J. Biomechanics , vol.36 , Issue.4 , pp. 537-544
    • Udofia, I.J.1    Jin, Z.M.2
  • 55
    • 0033630259 scopus 로고    scopus 로고
    • A comparative joint simulator study of the wear of metal-on-metal and alternative material combinations in hip replacements
    • Goldsmith, A. A., Dowson, D., Isaac, G. H., and Lancaster, J. G. A comparative joint simulator study of the wear of metal-on-metal and alternative material combinations in hip replacements. Proc. Instn Mech. Engrs, Part H: J. Engineering in Medicine, 2000, 214(1), 39-47.
    • (2000) Proc. Instn Mech. Engrs, Part H: J. Engineering in Medicine , vol.214 , Issue.1 , pp. 39-47
    • Goldsmith, A.A.1    Dowson, D.2    Isaac, G.H.3    Lancaster, J.G.4
  • 56
    • 2542607724 scopus 로고    scopus 로고
    • Changes in the contact area during the beddihg-in wear of different sizes of metal on metal hip prostheses
    • Hu, X. Q., Issac, G. H., and Fisher, J. Changes in the contact area during the beddihg-in wear of different sizes of metal on metal hip prostheses. J. Biomed. Mater. Res. A, 2004, 14, 145-149.
    • (2004) J. Biomed. Mater. Res. A , vol.14 , pp. 145-149
    • Hu, X.Q.1    Issac, G.H.2    Fisher, J.3
  • 58
    • 33947590365 scopus 로고    scopus 로고
    • Effect of bearing geometry and structure support on transient elastohydrodynamic lubrication of metal-on-metal hip implants
    • Liu, F., Jin, Z., Roberts, P., and Grigoris, P. Effect of bearing geometry and structure support on transient elastohydrodynamic lubrication of metal-on-metal hip implants. J. Biomechanics, 2007, 40(6), 1340-1349.
    • (2007) J. Biomechanics , vol.40 , Issue.6 , pp. 1340-1349
    • Liu, F.1    Jin, Z.2    Roberts, P.3    Grigoris, P.4
  • 59
    • 0035229408 scopus 로고    scopus 로고
    • The effect of femoral head diameter upon lubrication and wear of metal-on-metal total hip replacements
    • Smith, S. L., Dowson, D., and Goldsmith, A. A. The effect of femoral head diameter upon lubrication and wear of metal-on-metal total hip replacements. Proc. Instn Mech. Engrs, Part H: J. Engineering in Medicine, 2001, 215(H2), 161-170.
    • (2001) Proc. Instn Mech. Engrs, Part H: J. Engineering in Medicine , vol.215 , Issue.H2 , pp. 161-170
    • Smith, S.L.1    Dowson, D.2    Goldsmith, A.A.3
  • 64
    • 0344306477 scopus 로고    scopus 로고
    • Ion release in stable hip arthroplasties using metal-on-metal articulating surfaces: A comparison between short- and medium-term results
    • Savarino, L., Granchi, D., Ciapetti, G., Cenni, E., Greco, M., Retini, R., Veronesi, C. A., Baldini, N., and Glunti, A. Ion release in stable hip arthroplasties using metal-on-metal articulating surfaces: a comparison between short- and medium-term results. J. Biomed. Mater. Res. A, 2003, 66(3), 450-456.
    • (2003) J. Biomed. Mater. Res. A , vol.66 , Issue.3 , pp. 450-456
    • Savarino, L.1    Granchi, D.2    Ciapetti, G.3    Cenni, E.4    Greco, M.5    Retini, R.6    Veronesi, C.A.7    Baldini, N.8    Glunti, A.9
  • 65
    • 18244384199 scopus 로고    scopus 로고
    • Serum levels of cobalt and chromium in patients with Sikomet metal-metal total hip replacements
    • Milosev, I., Pisot, V., and Campbell, P. Serum levels of cobalt and chromium in patients with Sikomet metal-metal total hip replacements. J. Orthop., Res., 2005, 23(3), 526-535.
    • (2005) J. Orthop., Res , vol.23 , Issue.3 , pp. 526-535
    • Milosev, I.1    Pisot, V.2    Campbell, P.3
  • 66
    • 24344495778 scopus 로고    scopus 로고
    • How do serum cobalt and chromium levels change after metal-on-metal hip resurfacing?
    • Back, D. L., Young, D. A., and Shimmin, A. J. How do serum cobalt and chromium levels change after metal-on-metal hip resurfacing? Clin. Orthop. Relat. Res., 2005, 438, 177-181.
    • (2005) Clin. Orthop. Relat. Res , vol.438 , pp. 177-181
    • Back, D.L.1    Young, D.A.2    Shimmin, A.J.3
  • 70
    • 0034117155 scopus 로고    scopus 로고
    • Dissemination of wear particles to the liver, spleen, and abdominal lymph nodes of patients with hip or knee replacement
    • Urban, R. M., Jacobs, J. J., Tomlinson, M. J., Gavrilmic, J., Black, I., and Peoc'h, M. Dissemination of wear particles to the liver, spleen, and abdominal lymph nodes of patients with hip or knee replacement. J. Bone Jt Surg. Am., 2000, 82(4), 457-476.
    • (2000) J. Bone Jt Surg. Am , vol.82 , Issue.4 , pp. 457-476
    • Urban, R.M.1    Jacobs, J.J.2    Tomlinson, M.J.3    Gavrilmic, J.4    Black, I.5    Peoc'h, M.6
  • 72
    • 0031727764 scopus 로고    scopus 로고
    • Metal release in patients who have had a primary total hip arthroplasty. A prospective, controlled, longitudinal study
    • Jacobs, J. J., Skipor, A. K., Patterson, J. M., Hallab, N. J., Paprosky, W. G., Black, J., and Galante, J. O. Metal release in patients who have had a primary total hip arthroplasty. A prospective, controlled, longitudinal study. J. Bone Jt Surg. Am., 1998, 80(10), 1447-1458.
    • (1998) J. Bone Jt Surg. Am , vol.80 , Issue.10 , pp. 1447-1458
    • Jacobs, J.J.1    Skipor, A.K.2    Patterson, J.M.3    Hallab, N.J.4    Paprosky, W.G.5    Black, J.6    Galante, J.O.7
  • 75
    • 9644273921 scopus 로고    scopus 로고
    • A hip joint simulator study of the performance of metal-on-metal joints. Part II: Design
    • Dowson, D., Hardaker, C., Flett, M., and Isaac, G. H. A hip joint simulator study of the performance of metal-on-metal joints. Part II: design. J. Arthroplasty, 2004, 19(8, Suppl. 3), 124-130.
    • (2004) J. Arthroplasty , vol.19 , Issue.8 and SUPPL. 3 , pp. 124-130
    • Dowson, D.1    Hardaker, C.2    Flett, M.3    Isaac, G.H.4
  • 76
    • 0041527157 scopus 로고    scopus 로고
    • Levels of metal ions after small-,and large-diameter metal-on-metal hip arthrdplasty
    • Clarke, M. T., Lee, P. T., Arora, A., and War, R. N. Levels of metal ions after small-,and large-diameter metal-on-metal hip arthrdplasty. J. Bone Jt Surg. Br., 2003, 85(6), 913-917.
    • (2003) J. Bone Jt Surg. Br , vol.85 , Issue.6 , pp. 913-917
    • Clarke, M.T.1    Lee, P.T.2    Arora, A.3    War, R.N.4
  • 77
    • 33750870614 scopus 로고    scopus 로고
    • Current in vivo wear of metal-on-metal. bearings assessed by exercise-related rite in plasma cobalt level
    • Khan, M., Takahashi, T., Kuiper, J. H., Sieniawska, C. E., Takagi, K., and Richardson, J. B. Current in vivo wear of metal-on-metal. bearings assessed by exercise-related rite in plasma cobalt level. J. Orthop. Res., 2006, 24(11), 2029-2035.
    • (2006) J. Orthop. Res , vol.24 , Issue.11 , pp. 2029-2035
    • Khan, M.1    Takahashi, T.2    Kuiper, J.H.3    Sieniawska, C.E.4    Takagi, K.5    Richardson, J.B.6
  • 78
    • 0028946946 scopus 로고
    • Human exposure to toide metals: Factors influencing interpretation of biomonitoring results
    • Christensen, J. Human exposure to toide metals: factors influencing interpretation of biomonitoring results. Sci. Total Environ., 1995, 166, 89-135.
    • (1995) Sci. Total Environ , vol.166 , pp. 89-135
    • Christensen, J.1
  • 81
    • 16844377563 scopus 로고    scopus 로고
    • The relationship between activity and ions in patients with metal-on-metal bearing hip prostheses
    • Heisel, C., Silva, M., Skipor, A. K., Jacobs, J. J., and Schmalzried, T. P. The relationship between activity and ions in patients with metal-on-metal bearing hip prostheses. J. Bone Jt Surg. Am., 2005, 87(4), 781-787.
    • (2005) J. Bone Jt Surg. Am , vol.87 , Issue.4 , pp. 781-787
    • Heisel, C.1    Silva, M.2    Skipor, A.K.3    Jacobs, J.J.4    Schmalzried, T.P.5
  • 82
    • 84929221323 scopus 로고    scopus 로고
    • Exercise-related cobalt rise: A novel technique to determine in-vivo wear performance of metal-on-metal bearing hip arthroplasty
    • Southampton, UK, 5-6 July
    • Khan, M., Kuiper,, J.-H., and Richardson, J. B. Exercise-related cobalt rise: a novel technique to determine in-vivo wear performance of metal-on-metal bearing hip arthroplasty. In Proceedings of the British Orthopaedic Research Society Meeting, Southampton, UK, 5-6 July 2006.
    • (2006) Proceedings of the British Orthopaedic Research Society Meeting
    • Khan, M.1    Kuiper, J.-H.2    Richardson, J.B.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.