메뉴 건너뛰기




Volumn 82, Issue 6, 2007, Pages 337-341

Comparison of dynamic contour tonometry (Pascal®) with pneumotonometry and Goldmann tonometry;Comparación del tonómetro Pascal® con el neumotonómetro y el tonómetro Goldmann

Author keywords

Dynamic contour tonometry; Goldmann tonometer; Intraocular pressure; Pascal; Pneumotonometry

Indexed keywords

ARTICLE; CLINICAL TRIAL; COMPARATIVE STUDY; CONTROLLED CLINICAL TRIAL; CONTROLLED STUDY; HUMAN; INSTRUMENTATION; OCULOPLETHYSMOGRAPHY; RANDOMIZED CONTROLLED TRIAL;

EID: 38449100075     PISSN: 03656691     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (8)

References (7)
  • 1
    • 23744463890 scopus 로고    scopus 로고
    • Dynamic contour tonometry for intraocular pressure measurement
    • Kamppeter BA, Jonas JB. Dynamic contour tonometry for intraocular pressure measurement. Am J Ophthalmol 2005; 140: 318-320.
    • (2005) Am J Ophthalmol , vol.140 , pp. 318-320
    • Kamppeter, B.A.1    Jonas, J.B.2
  • 2
    • 28444475214 scopus 로고    scopus 로고
    • The relative effects of corneal thickness and age on Goldmann applanation tonometry and dynamic contour tonometry
    • Kotecha A, White ET, Shewry JM, Garway-Heath DF. The relative effects of corneal thickness and age on Goldmann applanation tonometry and dynamic contour tonometry. Br J Ophthalmol 2005; 89: 1572-1575.
    • (2005) Br J Ophthalmol , vol.89 , pp. 1572-1575
    • Kotecha, A.1    White, E.T.2    Shewry, J.M.3    Garway-Heath, D.F.4
  • 3
    • 22544486553 scopus 로고    scopus 로고
    • Comparison of dynamic contour tonometry with goldmann applanation tonometry over a wide range of central corneal thickness
    • Doyle A, Lachkar Y. Comparison of dynamic contour tonometry with goldmann applanation tonometry over a wide range of central corneal thickness. J Glaucoma 2005; 14: 288-292.
    • (2005) J Glaucoma , vol.14 , pp. 288-292
    • Doyle, A.1    Lachkar, Y.2
  • 4
    • 27744519845 scopus 로고    scopus 로고
    • Clinical comparison of contour and applanation tonometry and their relationship to pachymetry
    • Kniestedt C, Lin S, Choe J, Bostrom A, Nee M, Stamper RL. Clinical comparison of contour and applanation tonometry and their relationship to pachymetry. Arch Ophthalmol 2005; 123: 1532-1537.
    • (2005) Arch Ophthalmol , vol.123 , pp. 1532-1537
    • Kniestedt, C.1    Lin, S.2    Choe, J.3    Bostrom, A.4    Nee, M.5    Stamper, R.L.6
  • 5
    • 30344436327 scopus 로고    scopus 로고
    • Intraocular pressure measurement-comparison of dynamic contour tonometry and goldmann applanation tonometry
    • Schneider E, Grehn F. Intraocular pressure measurement-comparison of dynamic contour tonometry and goldmann applanation tonometry. J Glaucoma 2006; 15: 2-6.
    • (2006) J Glaucoma , vol.15 , pp. 2-6
    • Schneider, E.1    Grehn, F.2
  • 6
    • 4344659799 scopus 로고    scopus 로고
    • Comparison of dynamic contour tonometry with goldmann applanation tonometry
    • Kaufmann C, Bachmann LM, Thiel MA. Comparison of dynamic contour tonometry with goldmann applanation tonometry. Invest Ophthalmol Vis Sci 2004; 45: 3118-3121.
    • (2004) Invest Ophthalmol Vis Sci , vol.45 , pp. 3118-3121
    • Kaufmann, C.1    Bachmann, L.M.2    Thiel, M.A.3
  • 7
    • 24944580479 scopus 로고    scopus 로고
    • Dynamic contour tonometry versus goldmann applanation tonometry: A comparative study
    • Pache M, Wilmsmeyer S, Lautebach S, Funk J. Dynamic contour tonometry versus goldmann applanation tonometry: a comparative study. Graefes Arch Exp Ophthalmol 2005; 243: 763-767
    • (2005) Graefes Arch Exp Ophthalmol , vol.243 , pp. 763-767
    • Pache, M.1    Wilmsmeyer, S.2    Lautebach, S.3    Funk, J.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.