Volumn 34, Issue 2, 2008, Pages 239-251

Real-Time Freehand 3D Ultrasound Calibration

Author keywords

Calibration; Freehand three dimensional ultrasound; Real time

Indexed keywords

CALIBRATION; IMAGE RECONSTRUCTION; REAL TIME SYSTEMS;

EID: 38349145967     PISSN: 03015629     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.ultrasmedbio.2007.07.020     Document Type: Article
Times cited : (49)

References (32)
  • 5
    • 0027469612 scopus 로고
    • Speed of sound in pure water as a function of temperature
    • Bilaniuk N., and Wong G.S.K. Speed of sound in pure water as a function of temperature. J Acoust Soc Am 93 3 (1993) 1609-1612
    • (1993) J Acoust Soc Am , vol.93 , Issue.3 , pp. 1609-1612
    • Bilaniuk, N.1    Wong, G.S.K.2
  • 9
    • 79551682597 scopus 로고    scopus 로고
    • Proceedings of the 9th International Conference on Medical Image Computing and Computer-Assisted Intervention, Lecture Notes in Computer Science, Springer Vol. 4190
    • Chen T.K., Abolmaesumi P., Thurston A.D., and Ellis R.E. Automated 3D freehand ultrasound calibration with real-time accuracy control. Proceedings of the 9th International Conference on Medical Image Computing and Computer-Assisted Intervention, Lecture Notes in Computer Science (2006), Springer 899-906 Vol. 4190
    • (2006) Automated 3D freehand ultrasound calibration with real-time accuracy control , pp. 899-906
    • Chen, T.K.1    Abolmaesumi, P.2    Thurston, A.D.3    Ellis, R.E.4
  • 11
    • 23644457021 scopus 로고    scopus 로고
    • A phantom with reduced complexity for spatial 3-D ultrasound calibration
    • Dandekar S., Li Y., Molloy J., and Hossack J. A phantom with reduced complexity for spatial 3-D ultrasound calibration. Ultras Med Biol 31 8 (2005) 1083-1093
    • (2005) Ultras Med Biol , vol.31 , Issue.8 , pp. 1083-1093
    • Dandekar, S.1    Li, Y.2    Molloy, J.3    Hossack, J.4
  • 12
    • 0028597060 scopus 로고
    • 3D ultrasonic image feature localization based on magnetic scanhead tracking: in vitro calibration and validation
    • Detmer P.R., Bashein G., Hodges T., Beach K.W., Filer E.P., Burns D.H., and Stradness Jr. D.E. 3D ultrasonic image feature localization based on magnetic scanhead tracking: in vitro calibration and validation. Ultras Med Biol 20 9 (1994) 923-936
    • (1994) Ultras Med Biol , vol.20 , Issue.9 , pp. 923-936
    • Detmer, P.R.1    Bashein, G.2    Hodges, T.3    Beach, K.W.4    Filer, E.P.5    Burns, D.H.6    Stradness Jr., D.E.7
  • 14
    • 17044374697 scopus 로고    scopus 로고
    • A mechanical instrument for 3D ultrasound probe calibration
    • Gee A.H., Houghton N.E., Treece G.M., and Prager R.W. A mechanical instrument for 3D ultrasound probe calibration. Ultras Med Biol 31 4 (2005) 505-518
    • (2005) Ultras Med Biol , vol.31 , Issue.4 , pp. 505-518
    • Gee, A.H.1    Houghton, N.E.2    Treece, G.M.3    Prager, R.W.4
  • 16
    • 20444464721 scopus 로고    scopus 로고
    • Temporal calibration of freehand three-dimensional ultrasound using image alignment
    • Gooding M.J., Kennedy S.H., and Noble J.A. Temporal calibration of freehand three-dimensional ultrasound using image alignment. Ultras Med Biol 31 7 (2005) 919-927
    • (2005) Ultras Med Biol , vol.31 , Issue.7 , pp. 919-927
    • Gooding, M.J.1    Kennedy, S.H.2    Noble, J.A.3
  • 17
    • 33745131137 scopus 로고    scopus 로고
    • Rapid, easy and reliable calibration for freehand 3D ultrasound
    • Hsu P.-W., Prager R.W., Gee A.H., and Treece G.M. Rapid, easy and reliable calibration for freehand 3D ultrasound. Ultras Med Biol 32 6 (2006) 823-835
    • (2006) Ultras Med Biol , vol.32 , Issue.6 , pp. 823-835
    • Hsu, P.-W.1    Prager, R.W.2    Gee, A.H.3    Treece, G.M.4
  • 18
    • 9644274077 scopus 로고    scopus 로고
    • Development of a portable 3D ultrasound imaging system for musculosketetal tissues
    • Huang Q.H., Zheng Y.P., Lu M.H., and Chi Z.R. Development of a portable 3D ultrasound imaging system for musculosketetal tissues. Ultrasonics 43 (2005) 153-163
    • (2005) Ultrasonics , vol.43 , pp. 153-163
    • Huang, Q.H.1    Zheng, Y.P.2    Lu, M.H.3    Chi, Z.R.4
  • 19
    • 33744829272 scopus 로고    scopus 로고
    • Proceedings of the 8th International Conference on Medical Image Computing and Computer-Assisted Intervention, Lecture Notes in Computer Science, Springer-Verlag Vol. 3750
    • Khamene A., and Sauer F. A novel phantom-less spatial and temporal ultrasound calibration method. Proceedings of the 8th International Conference on Medical Image Computing and Computer-Assisted Intervention, Lecture Notes in Computer Science (2005), Springer-Verlag 65-72 Vol. 3750
    • (2005) A novel phantom-less spatial and temporal ultrasound calibration method , pp. 65-72
    • Khamene, A.1    Sauer, F.2
  • 21
    • 0345707660 scopus 로고    scopus 로고
    • Probe calibration for freehand 3-D ultrasound
    • Lindseth F., Tangen G.A., Langø T., and Bang J. Probe calibration for freehand 3-D ultrasound. Ultras Med Biol 29 11 (2003) 1607-1623
    • (2003) Ultras Med Biol , vol.29 , Issue.11 , pp. 1607-1623
    • Lindseth, F.1    Tangen, G.A.2    Langø, T.3    Bang, J.4
  • 22
    • 0034056419 scopus 로고    scopus 로고
    • Reconstruction and visualization of irregularly sampled three- and four-dimensional ultrasound data for cerebrovascular applications
    • Meairs S., Beyer J., and Hennerici M. Reconstruction and visualization of irregularly sampled three- and four-dimensional ultrasound data for cerebrovascular applications. Ultras Med Biol 26 2 (2000) 263-272
    • (2000) Ultras Med Biol , vol.26 , Issue.2 , pp. 263-272
    • Meairs, S.1    Beyer, J.2    Hennerici, M.3
  • 23
    • 13644249894 scopus 로고    scopus 로고
    • A review of calibration techniques for freehand 3-D ultrasound systems
    • Mercier L., Langø T., Lindsesth F., and Collins D.L. A review of calibration techniques for freehand 3-D ultrasound systems. Ultras Med Biol 31 4 (2005) 449-471
    • (2005) Ultras Med Biol , vol.31 , Issue.4 , pp. 449-471
    • Mercier, L.1    Langø, T.2    Lindsesth, F.3    Collins, D.L.4
  • 24
    • 0035661105 scopus 로고    scopus 로고
    • Beam calibration without a phantom for creating a 3-D freehand ultrasound system
    • Muratore D.M., and Galloway Jr. R.L. Beam calibration without a phantom for creating a 3-D freehand ultrasound system. Ultras Med Biol 27 11 (2001) 1557-1566
    • (2001) Ultras Med Biol , vol.27 , Issue.11 , pp. 1557-1566
    • Muratore, D.M.1    Galloway Jr., R.L.2
  • 26
    • 0034804115 scopus 로고    scopus 로고
    • A fast calibration method for 3-D tracking of ultrasound images using a spatial localizer
    • Pagoulatos N., Haynor D.R., and Kim Y. A fast calibration method for 3-D tracking of ultrasound images using a spatial localizer. Ultras Med Biol 27 9 (2001) 1219-1229
    • (2001) Ultras Med Biol , vol.27 , Issue.9 , pp. 1219-1229
    • Pagoulatos, N.1    Haynor, D.R.2    Kim, Y.3
  • 27
    • 0033138697 scopus 로고    scopus 로고
    • Stradx: Real-time acquisition and visualization of freehand three-dimensional ultrasound
    • Prager R.W., Gee A.H., and Berman L.H. Stradx: Real-time acquisition and visualization of freehand three-dimensional ultrasound. Med Image Anal 3 2 (1999) 129-140
    • (1999) Med Image Anal , vol.3 , Issue.2 , pp. 129-140
    • Prager, R.W.1    Gee, A.H.2    Berman, L.H.3
  • 29
    • 10844256598 scopus 로고    scopus 로고
    • Confhusius: A robust and fully automatic calibration method for 3D freehand ultrasound
    • Rousseau F., Hellier P., and Barillot C. Confhusius: A robust and fully automatic calibration method for 3D freehand ultrasound. Med Image Anal 9 1 (2005) 25-38
    • (2005) Med Image Anal , vol.9 , Issue.1 , pp. 25-38
    • Rousseau, F.1    Hellier, P.2    Barillot, C.3
  • 30
    • 33746893445 scopus 로고    scopus 로고
    • A novel temporal calibration method for 3D ultrasound
    • Rousseau F., Hellier P., and Barillot C. A novel temporal calibration method for 3D ultrasound. IEEE Trans Med Imaging 25 (2006) 1108-1112
    • (2006) IEEE Trans Med Imaging , vol.25 , pp. 1108-1112
    • Rousseau, F.1    Hellier, P.2    Barillot, C.3