1
-
-
0010990601
-
Dosimetric precision requirements in radiation therapy
-
Brahme A. Dosimetric precision requirements in radiation therapy. Acta Radiol Oncol 23 (1984) 379-391
-
(1984)
Acta Radiol Oncol
, vol.23
, pp. 379-391
-
-
Brahme, A.1
-
2
-
-
1142304255
-
Update of AAPM Task Group No. 43 Report: a revised AAPM protocol for brachytherapy dose calculations
-
Rivard M.J., Coursey B.M., DeWerd L.A., et al. Update of AAPM Task Group No. 43 Report: a revised AAPM protocol for brachytherapy dose calculations. Med Phys 31 (2004) 633
-
(2004)
Med Phys
, vol.31
, pp. 633
-
-
Rivard, M.J.1
Coursey, B.M.2
DeWerd, L.A.3
-
3
-
-
38349085281
-
-
International Commission on Radiation Units and Measurements (ICRU), Dose and volume specification for reporting intracavitary therapy in gynecology, ICRU report 38. Bethesda, MD; 1985.
-
-
-
-
4
-
-
0030801752
-
Code of practice for brachytherapy physics: report of the AAPM Radiation Therapy Committee Task Group No. 56
-
Nath R., Anderson L.L., Meli J.A., Olch A.J., Stitt J.A., and Williamson J.F. Code of practice for brachytherapy physics: report of the AAPM Radiation Therapy Committee Task Group No. 56. Med Phys 24 (1997) 1557-1598
-
(1997)
Med Phys
, vol.24
, pp. 1557-1598
-
-
Nath, R.1
Anderson, L.L.2
Meli, J.A.3
Olch, A.J.4
Stitt, J.A.5
Williamson, J.F.6
-
6
-
-
0028320064
-
Activity determination of 192Ir solid sources by ionization chamber measurements using calculated corrections for self-absorption
-
Büermann L., Kramer H.-M., Schrader H., and Selbacj H.-J. Activity determination of 192Ir solid sources by ionization chamber measurements using calculated corrections for self-absorption. Nucl Instr Meth A 339 (1994) 369-376
-
(1994)
Nucl Instr Meth A
, vol.339
, pp. 369-376
-
-
Büermann, L.1
Kramer, H.-M.2
Schrader, H.3
Selbacj, H.-J.4
-
8
-
-
38349126717
-
-
192Ir brachytherapy sources, NPL REPORT DQL-RD 004. National Physics Laboratory (NPL),United Kingdom; 2006.
-
-
-
-
9
-
-
38349185555
-
-
International Atomic Energy Agency (IAEA), Calibration of photon and beta ray sources used in brachytherapy, IAEA-TECDOC-1274. Vienna, Austria; 2002.
-
-
-
-
10
-
-
38349091372
-
-
Venselaar J, Pèrez-Calatayud J, editors. A practical guide to quality control of brachytherapy equipment: ESTRO Booklet no. 8; 2004.
-
-
-
-
11
-
-
0028348962
-
Intercomparison of calibration procedures for Ir-192 HDR sources in The Netherlands and Belgium
-
Venselaar J.L.M., Brouwer W.F.M., van Straaten B.H.M., and Aalbers A.H.L. Intercomparison of calibration procedures for Ir-192 HDR sources in The Netherlands and Belgium. Radiother Oncol 30 (1994) 155-161
-
(1994)
Radiother Oncol
, vol.30
, pp. 155-161
-
-
Venselaar, J.L.M.1
Brouwer, W.F.M.2
van Straaten, B.H.M.3
Aalbers, A.H.L.4
-
13
-
-
0026490741
-
A new reentrant ionization chamber for the calibration of Iridium-192 high dose rate sources
-
Goetsch S.J., Attix F.H., DeWerd L.A., and Thomadsen B.R. A new reentrant ionization chamber for the calibration of Iridium-192 high dose rate sources. Int J Radiat Oncol Biol Phys 24 (1992) 167-170
-
(1992)
Int J Radiat Oncol Biol Phys
, vol.24
, pp. 167-170
-
-
Goetsch, S.J.1
Attix, F.H.2
DeWerd, L.A.3
Thomadsen, B.R.4
-
14
-
-
38349137961
-
-
International Commission on Radiation Units and Measurements (ICRU), Dose and volume specification for reporting interstitial therapy, ICRU report 58. Bethesda, MD; 1997.
-
-
-
-
16
-
-
38349151572
-
-
International Organization for Standardization (ISO), Guide to the expression of uncertainties in measurements. 1995.
-
-
-
-
17
-
-
38349140376
-
-
192Ir source strength determination in Sweden. Swedish Radiation Protection Authority, Sweden, SSI-report 2007:13. 2007.
-
-
-
-
18
-
-
0026785361
-
Thermal and scatter effects on the radiation sensitivity of well chambers used for high dose rate Ir-192 calibrations
-
Podgorsak M.B., DeWerd L.A., Thomadsen B.R., and Paliwal B.R. Thermal and scatter effects on the radiation sensitivity of well chambers used for high dose rate Ir-192 calibrations. Med Phys 19 (1992) 1311-1314
-
(1992)
Med Phys
, vol.19
, pp. 1311-1314
-
-
Podgorsak, M.B.1
DeWerd, L.A.2
Thomadsen, B.R.3
Paliwal, B.R.4
-
19
-
-
38349171776
-
-
192Ir sources. Report from Radiation Physics. Göteborg University, Sweden; 1995.
-
-
-
-
20
-
-
38349162844
-
-
International Atomic Energy Agency (IAEA), Absorbed dose determination in external beam radiotherapy, IAEA TRS 398. Vienna, Austria; 2000.
-
-
-
|