-
1
-
-
38149135384
-
-
http://www.idef.com
-
-
-
-
3
-
-
0030175670
-
Automated Hexahedral Mesh Generation from Biomedical Image Data: Applications in Limb Prosthetics
-
Santosh, G.Z., Sanders, J.E., Turkiyyah, G.M.: Automated Hexahedral Mesh Generation from Biomedical Image Data: Applications in Limb Prosthetics. IEEE Transactions On Rehabilitation Engineering 4(2) (1996)
-
(1996)
IEEE Transactions On Rehabilitation Engineering
, vol.4
, Issue.2
-
-
Santosh, G.Z.1
Sanders, J.E.2
Turkiyyah, G.M.3
-
4
-
-
0032276747
-
MRI investigation of musculoskeletal action of transfemoral residual limb inside a prosthetic socket
-
October 29-November 1, Hong Kong, China, pp
-
Ming, Z., Mak, A.F.T., Chung, A.I.K., Chung, K.H.: MRI investigation of musculoskeletal action of transfemoral residual limb inside a prosthetic socket. In: Proceeding 20th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, Part 5/6, October 29-November 1, 1998, Hong Kong, China, pp. 2741-2743 (1998)
-
(1998)
Proceeding 20th Annual International Conference of the IEEE Engineering in Medicine and Biology Society
, Issue.PART 5 6
, pp. 2741-2743
-
-
Ming, Z.1
Mak, A.F.T.2
Chung, A.I.K.3
Chung, K.H.4
-
5
-
-
10444245805
-
3D reconstruction of the structure of a residual limb for customising the design of a prosthetic socket
-
Shuxian, Z., Wanhua, Z., Bingheng, L.: 3D reconstruction of the structure of a residual limb for customising the design of a prosthetic socket. Medical Engineering & Physics (27), 67-74 (2005)
-
(2005)
Medical Engineering & Physics
, vol.27
, pp. 67-74
-
-
Shuxian, Z.1
Wanhua, Z.2
Bingheng, L.3
-
7
-
-
3242655551
-
Load transfer mechanics between trans-tibial prosthetic socket and residual limb dynamic effects
-
Lee, W.C.C., Zhang, M., Jia, X.: Load transfer mechanics between trans-tibial prosthetic socket and residual limb dynamic effects. Journal of Biomechanics 37, 1371-1377 (2004)
-
(2004)
Journal of Biomechanics
, vol.37
, pp. 1371-1377
-
-
Lee, W.C.C.1
Zhang, M.2
Jia, X.3
-
8
-
-
4744352767
-
Finite element modelling of the contact interface between trans-tibial residual limb and prosthetic socket
-
Lee, W.C.C., Zhang, M., Jia, X., Cheung, J.T.M.: Finite element modelling of the contact interface between trans-tibial residual limb and prosthetic socket. Medical Engineering & Physics (26), 655-662 (2004)
-
(2004)
Medical Engineering & Physics
, vol.26
, pp. 655-662
-
-
Lee, W.C.C.1
Zhang, M.2
Jia, X.3
Cheung, J.T.M.4
-
9
-
-
2442607619
-
Nonlinear viscoelastic material estimation of lower extremity residual limb tissues
-
Tönuk, E., Silver-Thorn, M.B.: Nonlinear viscoelastic material estimation of lower extremity residual limb tissues. Journal of Biomechanical Engineering 126(2), 289-300 (2004)
-
(2004)
Journal of Biomechanical Engineering
, vol.126
, Issue.2
, pp. 289-300
-
-
Tönuk, E.1
Silver-Thorn, M.B.2
-
10
-
-
78649842222
-
Automation of prosthetic socket design and fabrication using computer-aided-design/computer-aided- engineering and rapid prototyping techniques
-
Singapore
-
Cheng, T.K., Sin, P.L.V., Fye, T.K., Lin, L.S.: Automation of prosthetic socket design and fabrication using computer-aided-design/computer-aided- engineering and rapid prototyping techniques. In: Proceeding First National Symposium on Prosthetics and Orthotics. Singapore (1998)
-
(1998)
Proceeding First National Symposium on Prosthetics and Orthotics
-
-
Cheng, T.K.1
Sin, P.L.V.2
Fye, T.K.3
Lin, L.S.4
-
11
-
-
0032351290
-
Shererolithiography and prosthetic test socket manufacture: A cost/benefit analysis
-
Freeman, D., Wontorcik, L.: Shererolithiography and prosthetic test socket manufacture: a cost/benefit analysis. Journal of Prothestics and Orthotics 10(1) (1998)
-
(1998)
Journal of Prothestics and Orthotics
, vol.10
, Issue.1
-
-
Freeman, D.1
Wontorcik, L.2
-
12
-
-
35248862562
-
Tetrahedral mass spring model for fast soft tissue deformation
-
Springer, Heidelberg
-
Mollemans, W., Schutyser, F., Cleynenbreugel, J.V., Suetens, P.: Tetrahedral mass spring model for fast soft tissue deformation. LNCS, vol. 2673(1), pp. 145-154. Springer, Heidelberg (2003)
-
(2003)
LNCS
, vol.2673
, Issue.1
, pp. 145-154
-
-
Mollemans, W.1
Schutyser, F.2
Cleynenbreugel, J.V.3
Suetens, P.4
-
13
-
-
31144446701
-
The quasi-static response of compliant prosthetic sockets for transtibial amputees using finite elements methods
-
Faustini, M.C., Neptune, R.R., Crawford, R.H.: The quasi-static response of compliant prosthetic sockets for transtibial amputees using finite elements methods. Medical Engineering & Physics N. 28, 114-121 (2006)
-
(2006)
Medical Engineering & Physics
, Issue.28
, pp. 114-121
-
-
Faustini, M.C.1
Neptune, R.R.2
Crawford, R.H.3
-
15
-
-
0035706069
-
State - of - the - art methods for geometric and biomechanical assessments of residual limbs: A review
-
Zheng, Y.P., et al.: State - of - the - art methods for geometric and biomechanical assessments of residual limbs: a review. Journal of Rehabilitation Research and Development. 38(5) (2001)
-
(2001)
Journal of Rehabilitation Research and Development
, vol.38
, Issue.5
-
-
Zheng, Y.P.1
-
16
-
-
33645531770
-
Reverse Engineering and rapid prototyping techniques to innovate prosthesis socket design
-
San Diego, CA, 60560P
-
Colombo, G., Bertetti, M., Bonacini, D., Magrassi, G.: Reverse Engineering and rapid prototyping techniques to innovate prosthesis socket design. In: Proceeding SPIE-IS&T Electronic Imaging, San Diego, CA, vol. 6056, 60560P (2006)
-
(2006)
Proceeding SPIE-IS&T Electronic Imaging
, vol.6056
-
-
Colombo, G.1
Bertetti, M.2
Bonacini, D.3
Magrassi, G.4
-
17
-
-
4744352767
-
Finite element modelling of the contact interface between trans-tibial residual limb and prosthetic socket
-
Lee, W.C.C., Zhang, M., Jia, X., Cheung, J.T.M.: Finite element modelling of the contact interface between trans-tibial residual limb and prosthetic socket. In: Medical Engineering & Physics N. 26, 655-662 (2004)
-
(2004)
Medical Engineering & Physics
, Issue.26
, pp. 655-662
-
-
Lee, W.C.C.1
Zhang, M.2
Jia, X.3
Cheung, J.T.M.4
|